Verification of improved patient outcomes with a partially implantable hearing aid, the SOUNDTEC direct hearing system

被引:26
|
作者
Roland, PS
Shoup, AG
Shea, MC
Richey, HS
Jones, DB
机构
[1] Univ Texas, SW Med Ctr, Dept Otolaryngol Head & Neck Surg, Dallas, TX 75390 USA
[2] Shea Hubbard & Futrell, Ear Nose & Throat Grp Inc, Memphis, TN USA
[3] SOUNDTEC Inc, Oklahoma City, OK USA
来源
LARYNGOSCOPE | 2001年 / 111卷 / 10期
关键词
hearing aids; implantable hearing aids; amplification;
D O I
10.1097/00005537-200110000-00002
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Introduction: Partially implantable hearing devices have been developed to address some of the user-perceived shortcomings of standard amplification systems. Partially implantable devices are purported to provide improved sound quality as a result of decreased occlusion, decreased feedback, and enhanced clarity resulting from increased high-frequency gain. Such improvements may result in greater user satisfaction. To justify selection of a partially implantable device and undergoing a minor surgical procedure, verification techniques must be used to document user improvement or increased satisfaction over conventional amplification. Objective. To evaluate patient satisfaction with the SOUNDTEC direct hearing system. Study Design: Within-subjects repeated measures design. Methods: Objective and subjective evaluation pre- and postimplantation with the SOUNDTEC device. Verification techniques included tonal functional gain measures with traditional amplification and the SOUNDTEC device, word recognition in quiet (NU-6) and in noise (SPIN), the Abbreviated Profile of Hearing Aid Benefit (APHAB), and the Hough Ear Institute Profile (HEIP). Results: Although there was no significant difference between optimal traditional amplification and the SOUNDTEC device for speech perception measures, the SOUNDTEC device yielded statistically significant increased high-frequency functional gain. Subjective reports indicated that the SOUNDTEC device provides a cleaner, more natural sound without feedback than traditional amplification. Conclusions. Partially implantable hearing aids may address some of the limitations of traditional amplification systems.
引用
收藏
页码:1682 / 1686
页数:5
相关论文
共 50 条
  • [1] Experience with the SOUNDTEC Implantable hearing aid
    Silverstein, H
    Atkins, J
    Thompson, JH
    Gilman, N
    OTOLOGY & NEUROTOLOGY, 2005, 26 (02) : 211 - 217
  • [2] Hearing acuity of the implantable hearing aid
    Saiki, T
    Gyo, K
    Yanagihara, N
    TRANSPLANTS AND IMPLANTS IN OTOLOGY - III, PROCEEDINGS, 1996, : 341 - 345
  • [3] IMPLANTABLE ELECTROMAGNETIC HEARING AID
    FREDRICK.JM
    TOMLINSO.RD
    DAVIS, ER
    AUDIOLOGY, 1972, 11 : 88 - 89
  • [4] The totally implantable hearing aid
    Zenner, HP
    FORTSCHRITT UND FORTBILDUNG IN DER MEDIZIN, BAND 25 (2001/2002), 2001, 25 : 251 - +
  • [5] Early clinical results: SOUNDTEC implantable hearing device phase II study
    Hough, JVD
    Dyer, RK
    Matthews, P
    Wood, MW
    LARYNGOSCOPE, 2001, 111 (01): : 1 - 8
  • [6] Safety and patient selection of totally implantable hearing aid surgery: Envoy system, Esteem
    Faramarz Memari
    Alimohamad Asghari
    Ahmad Daneshi
    Ali Jalali
    European Archives of Oto-Rhino-Laryngology, 2011, 268 : 1421 - 1425
  • [7] Safety and patient selection of totally implantable hearing aid surgery: Envoy system, Esteem
    Memari, Faramarz
    Asghari, Alimohamad
    Daneshi, Ahmad
    Jalali, Ali
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 2011, 268 (10) : 1421 - 1425
  • [8] Development of a totally implantable hearing aid
    Vujanic, A
    Pavelka, R
    Adamovic, N
    Kment, C
    Mitic, S
    Brenner, W
    Popovic, G
    2002 23RD INTERNATIONAL CONFERENCE ON MICROELECTRONICS, VOLS 1 AND 2, PROCEEDINGS, 2002, : 235 - 238
  • [9] Is a totally implantable hearing aid realistic?
    Suzuki, J
    Kodera, K
    TRANSPLANTS AND IMPLANTS IN OTOLOGY - III, PROCEEDINGS, 1996, : 315 - 322
  • [10] NEW DESIGN FOR AN IMPLANTABLE HEARING AID
    NUNLEY, JA
    AGNEW, J
    SMITH, GL
    ISA TRANSACTIONS, 1976, 15 (03) : 242 - 245