Doppler tissue imaging and color M-mode flow propagation velocity: Are they really preload independent?

被引:33
|
作者
Hsiao, SH [1 ]
Huang, WC [1 ]
Sy, CL [1 ]
Lin, SK [1 ]
Lee, TY [1 ]
Lin, CP [1 ]
机构
[1] Kaohsiung Vet Gen Hosp, Ctr Cardiovasc Dis, Div Cardiol, Dept Internal Med, Kaohsiung 813, Taiwan
关键词
D O I
10.1016/j.echo.2005.07.016
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study investigated the change in new diastolic indexes in patients with uremia who undergo regular hemodialysis (H/D). Methods: We studied 81 patients with uremia (41 men and 40 women) receiving regular H/D. All patients were in sinus rhythm before H/D. They had normal left ventricular systolic performance without regional wall-motion abnormality. Three patients were excluded because of atrial fibrillation after H/D. Patients were separated by the amount of body fluid removed during H/D procedure: 30 patients with H/D amount less than 2 kg (group 1), 33 patients with H/D amount between 2 and 3 kg (group 2), and 18 patients with H/D amount larger than 3 kg (group 3). They received complete transthoracic echocardiographic examinations. Flow propagation velocity (FPV) was measured by color M-mode echocardiography in apical 4-chamber view. Mitral annulus Doppler tissue velocities (peak systolic [Sal, early diastolic [Ea], and late diastolic [Aa]) were measured from septal, lateral, inferior, and posterior walls. All these parameters were obtained immediately before and after H/D. Paired data were compared. Results: In patients with removed fluid amount less than 2 kg (group 1), the change of all diastolic parameters showed insignificant change except FPV (peak mitral E, P = .14; peak mitral A, P = .916; FPV, P = .009; septal Sa, P = .173; septal Ea, P = .295; septal Aa, P = .649). In patients with H/D amount between 2 and 3 kg, the change of all diastolic parameters showed statistically significant difference except Sa (peak mitral E, P = .001; peak mitral A, P = .001; FPV, P = .001; Sa, P = .589; Ea, P = .001; Aa, P = .015). In patients with H/D amount larger than 3 kg, Sa still showed insignificant change. Ea, Aa, and FPV showed significant difference after H/D (peak mitral E, P = .001; peak mitral A, P = .035; FPV, P = .008; septal Sa, P = .777; septal Ea, P = .014; septal Aa, P = .048). Conclusion: In patients with normal left ventricular systolic function, FPV was preload dependent. Diastolic phase mitral annulus Doppler tissue velocities (Ea and Aa) behaved differently according to the amount removed during H/D. They were preload independent when the amount removed during H/D was less than 2 kg. When the amount removed during H/D was larger than 2 kg, diastolic phase mitral annulus Doppler tissue velocities changed significantly. That is to say, diastolic phase mitral annulus Doppler tissue velocities were not totally preload independent. For systolic phase mitral annulus Doppler tissue velocity index (Sa), it was preload independent.
引用
收藏
页码:1277 / 1284
页数:8
相关论文
共 50 条
  • [1] Color M-mode flow propagation velocity: is it really preload independent?
    Lin, SK
    Hsiao, SH
    Lee, TY
    Huang, WC
    Hsu, TL
    Mar, GY
    Liu, CP
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2005, 22 (08): : 636 - 641
  • [2] Color M-mode Doppler flow propagation velocity is a relatively preload-independent index of left ventricular filling
    Garcia, MJ
    Palac, RT
    Malenka, DJ
    Terrell, P
    Plehn, JF
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 1999, 12 (02) : 129 - 137
  • [3] Color M-mode Doppler flow propagation velocity in cardiac tamponade
    Togni, M
    Shabetai, R
    Blanchard, D
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) : 328 - 329
  • [4] Preload dependence of color M-mode Doppler flow propagation velocity in controls and in patients with left ventricular dysfunction
    Moller, JE
    Poulsen, SH
    Sondergaard, E
    Egstrup, K
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2000, 13 (10) : 902 - 909
  • [5] Color M-mode Doppler flow propagation velocity in cardiac tamponade - Reply
    Garcia, MJ
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2001, 37 (01) : 329 - 329
  • [6] Comparative value of tissue Doppler imaging and m-mode color Doppler mitral flow propagation velocity for the evaluation of left ventricular filling pressure
    Kidawa, M
    Coignard, L
    Drobinski, G
    Krzeminska-Pakula, M
    Thomas, D
    Komajda, M
    Isnard, R
    CHEST, 2005, 128 (04) : 2544 - 2550
  • [7] Color M-mode Doppler flow propagation velocity is a preload insensitive index of left ventricular relaxation: Animal and human validation
    Garcia, MJ
    Smedira, NG
    Greenberg, NL
    Main, M
    Firstenberg, MS
    Odabashian, J
    Thomas, JD
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (01) : 201 - 208
  • [8] LOAD INDEPENDENCE OF COLOR M-MODE FLOW PROPAGATION VELOCITY
    GARCIA, MJ
    OROURKE, DJ
    WIDMER, MC
    TERRELL, P
    MALENKA, DJ
    PALAC, RT
    PLEHN, JF
    CIRCULATION, 1995, 92 (08) : 1885 - 1885
  • [9] Propagation velocity of left ventricular filling flow measured by color M-mode Doppler echocardiography
    Kitabatake, A
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1998, 31 (06) : 1445 - 1445
  • [10] Hydrodynamics of color M-mode Doppler flow wave propagation velocity V(p): A computer study
    Vierendeels, JA
    Dick, E
    Verdonck, PR
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2002, 15 (03) : 219 - 224