Continuous glucose monitoring by means of mid-infrared transmission laser spectroscopy in vitro

被引:47
|
作者
Vrancic, Christian [1 ]
Fomichova, Anna [1 ]
Gretz, Norbert [2 ]
Herrmann, Carina [1 ]
Neudecker, Sabine [2 ]
Pucci, Annemarie [1 ]
Petrich, Wolfgang [1 ]
机构
[1] Heidelberg Univ, Kirchhoff Inst Phys, D-69120 Heidelberg, Germany
[2] Heidelberg Univ, Med Res Ctr, D-68167 Mannheim, Germany
关键词
QUANTUM CASCADE LASERS; EVANESCENT-WAVE SPECTROSCOPY; QUANTITATIVE-ANALYSIS; BLOOD-GLUCOSE; RAMAN-SPECTROSCOPY; ABSORPTION; SERUM; FRUCTOSE; SENSORS; FIBERS;
D O I
10.1039/c0an00537a
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The continuous surveillance of glucose concentration reduces short-term risks and long-term complications for people with diabetes mellitus, a disorder of glucose metabolism. As a first step towards the continuous monitoring of glucose, reagent-free transmission spectroscopy in the mid-infrared region has been carried out in vitro using a quantum cascade laser and an optical silver halide fiber. A 30 mu m gap in the fiber allowed for transmission spectroscopy of aqueous glucose solutions at a wavelength of 9.69 mu m, which is specific to a molecular vibration of glucose. A noise-equivalent concentration as low as 4 mg/dL was achieved at an average power of 1.8 mW and an integration time of 50 s. This is among the most precise of glucose measurements using mid-infrared spectroscopy. Even with the very low average laser power of 0.07 m W the sensitivity of previous results (using a fiber optical evanescent field analysis) has been improved upon by almost one order of magnitude. Finally, the impact of potentially interfering substances such as other carbohydrates was analyzed.
引用
收藏
页码:1192 / 1198
页数:7
相关论文
共 50 条
  • [1] Continuous glucose monitoring by means of fiber-based, mid-infrared laser spectroscopy
    Lambrecht, A.
    Beyer, T.
    Hebestreit, K.
    Mischler, R.
    Petrich, W.
    APPLIED SPECTROSCOPY, 2006, 60 (07) : 729 - 736
  • [2] Validation of mid-infrared spectroscopy for continuous glucose monitoring: the manage II study
    J-C Preiser
    A Brasseur
    D Fagnoul
    J-L Vincent
    Intensive Care Medicine Experimental, 3 (Suppl 1)
  • [3] In-vitro characteristics of a mid-infrared, continuous glucose sensor
    Herrmann, Carina
    Vrancic, Christian
    Fomichova, Anna
    Gretz, Norbert
    Hoecker, Sabine
    Pucci, Annemarie
    Petrich, Wolfgang
    BIOMEDICAL VIBRATIONAL SPECTROSCOPY IV: ADVANCES IN RESEARCH AND INDUSTRY, 2010, 7560
  • [4] Continuous glucose determination using fiber-based tunable mid-infrared laser spectroscopy
    Yu, Songlin
    Li, Dachao
    Chong, Hao
    Sun, Changyue
    Xu, Kexin
    OPTICS AND LASERS IN ENGINEERING, 2014, 55 : 78 - 83
  • [5] ICU glucose monitoring measured in plasma using mid-infrared spectroscopy
    T Heise
    L Nosek
    J Gable
    G Lim
    C Calentine
    Critical Care, 14 (Suppl 1):
  • [6] Mid-infrared laser applications in spectroscopy
    Tittel, FK
    Richter, D
    Fried, A
    SOLID-STATE MID-INFRARED LASER SOURCES, 2003, 89 : 445 - 510
  • [7] Online monitoring of exhaled breath using mid-infrared laser spectroscopy
    Muertz, Manfred
    Hering, Peter
    MID-INFRARED COHERENT SOURCES AND APPLICATIONS, 2008, : 535 - 555
  • [8] Mid-infrared laser measurements of aqueous glucose
    Guo, Bujin
    Wang, Yi
    Wang, Yang
    Le, Han Q.
    JOURNAL OF BIOMEDICAL OPTICS, 2007, 12 (02)
  • [9] Mid-infrared Quantum Cascade Laser Spectroscopy for Noninvasive, In Vivo Glucose Sensing
    Werth, Alexandra
    Liakat, Sabbir
    Gmachl, Claire
    DIABETES, 2017, 66 : A614 - A614
  • [10] In vitro glucose measurement using tunable mid-infrared laser spectroscopy combined with fiber-optic sensor
    Yu, Songlin
    Li, Dachao
    Chong, Hao
    Sun, Changyue
    Yu, Haixia
    Xu, Kexin
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (01): : 275 - 286