Electrochemical Aptasensor for Detection of Ochratoxin A

被引:2
|
作者
Shan, Yanqun [1 ]
Wang, Xiaoying [1 ]
机构
[1] Southeast Univ, Sch Publ Hlth, Key Lab Environm Med Engn, Minist Educ, Nanjing 210009, Jiangsu, Peoples R China
基金
中国国家自然科学基金;
关键词
ochratoxin A; detection technology; aptamer; electrochemical aptasensor; PERFORMANCE LIQUID-CHROMATOGRAPHY; IMPEDIMETRIC APTASENSOR; ULTRASENSITIVE DETECTION; DNA APTAMER; SENSITIVE DETECTION; GOLD NANOPARTICLES; SENSING PLATFORM; COCOA BEANS; BIOSENSOR; SIGNAL;
D O I
10.7536/PC171022
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Ochratoxin A (OTA) is a toxic secondary metabolite of small molecular weight mainly produced by Aspergillus and Penicillium species, which are widely found in food, agricultural products and animal feed. It has strong hepatotoxicity, nephrotoxicity, teratogenic and mutagenic effects, and is also a class. B carcinogens. In view of OTA's universality and harmfulness, the present situation of the commonly used detection methods of OTA is summarized and compared in this paper. Specifically, the application of new electrochemical aptasensor in OTA detection is mainly described. OTA electrochemical aptasensors are divided into three categories: configuration transformation type, affinity type and hybrid type. Their respective principles, characteristics and the latest research progress are discussed in detail. Furthermore, the summary of the future directions and the potential applications are given, which provides reference for the further research and application of OTA.
引用
收藏
页码:797 / 808
页数:12
相关论文
共 65 条
  • [1] Amperometric aptasensor for ochratoxin A based on the use of a gold electrode modified with aptamer, complementary DNA, SWCNTs and the redox marker Methylene Blue
    Abnous, Khalil
    Danesh, Noor Mohammad
    Alibolandi, Mona
    Ramezani, Mohammad
    Taghdisi, Seyed Mohammad
    [J]. MICROCHIMICA ACTA, 2017, 184 (04) : 1151 - 1159
  • [2] Alam A. U., 2018, Sensors and Actuators, B: Chemical, V254, P896, DOI DOI 10.1016/J.SNB.2017.07.127
  • [3] Determination of Ochratoxin A in wine by packed in-tube solid phase microextraction followed by high performance liquid chromatography coupled to tandem mass spectrometry
    Andrade, Mariane A.
    Lancas, Fernando M.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2017, 1493 : 41 - 48
  • [4] [Anonymous], 2006, 1307822006 GB
  • [5] Electrochemical DNA aptamer-based biosensor for OTA detection, using superparamagnetic nanoparticles
    Barthelmebs, Lise
    Hayat, Akhtar
    Limiadi, Ambrosius Wis
    Marty, Jean-Louis
    Noguer, Thierry
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2011, 156 (02): : 932 - 937
  • [6] Enzyme-Linked Aptamer Assays (ELAAs), based on a competition format for a rapid and sensitive detection of Ochratoxin A in wine
    Barthelmebs, Lise
    Jonca, Justyna
    Hayat, Akhtar
    Prieto-Simon, Beatriz
    Marty, Jean-Louis
    [J]. FOOD CONTROL, 2011, 22 (05) : 737 - 743
  • [7] An electrochemical competitive biosensor for ochratoxin A based on a DNA biotinylated aptamer
    Bonel, Laura
    Vidal, Juan C.
    Duato, Patricia
    Castillo, Juan R.
    [J]. BIOSENSORS & BIOELECTRONICS, 2011, 26 (07): : 3254 - 3259
  • [8] A generic amplification strategy for electrochemical aptasensors using a non-enzymatic nanoceria tag
    Bulbul, Gonca
    Hayat, Akhtar
    Andreescu, Silvana
    [J]. NANOSCALE, 2015, 7 (31) : 13230 - 13238
  • [9] New European Clinical Trial Regulation: What's Going On?
    Cagnazzo, Celeste
    Campora, Sara
    Arizio, Francesca
    Marchesi, Emanuela
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S1441 - S1442
  • [10] Impedimetric DNA Aptasensor for Sensitive Detection of Ochratoxin A in Food
    Castillo, Gabriela
    Lamberti, Ilaria
    Mosiello, Lucia
    Hianik, Tibor
    [J]. ELECTROANALYSIS, 2012, 24 (03) : 512 - 520