Automated contouring error detection based on supervised geometric attribute distribution models for radiation therapy: A general strategy

被引:46
|
作者
Chen, Hsin-Chen [1 ]
Tan, Jun [1 ]
Dolly, Steven [1 ]
Kavanaugh, James [1 ]
Anastasio, Mark A. [2 ]
Low, Daniel A. [3 ]
Li, H. Harold [1 ]
Altman, Michael [1 ]
Gay, Hiram [1 ]
Thorstad, Wade L. [1 ]
Mutic, Sasa [1 ]
Li, Hua [1 ]
机构
[1] Washington Univ, Dept Radiat Oncol, St Louis, MO 63110 USA
[2] Washington Univ, Dept Biomed Engn, St Louis, MO 63110 USA
[3] Univ Calif Los Angeles, Dept Radiat Oncol, Los Angeles, CA 90095 USA
关键词
contouring error detection; attribute distribution model; geometric attribute; principal component analysis; radiation therapy; ACTIVE SHAPE MODELS; DECISION-MAKING; VOLUME DELINEATION; QUALITY-ASSURANCE; TARGET VOLUMES; NECK ORGANS; ROC PLOTS; VARIABILITY; CANCER; ATLAS;
D O I
10.1118/1.4906197
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: One of the most critical steps in radiation therapy treatment is accurate tumor and critical organ-at-risk (OAR) contouring. Both manual and automated contouring processes are prone to errors and to a large degree of inter-and intraobserver variability. These are often due to the limitations of imaging techniques in visualizing human anatomy as well as to inherent anatomical variability among individuals. Physicians/physicists have to reverify all the radiation therapy contours of every patient before using them for treatment planning, which is tedious, laborious, and still not an error-free process. In this study, the authors developed a general strategy based on novel geometric attribute distribution (GAD) models to automatically detect radiation therapy OAR contouring errors and facilitate the current clinical workflow. Methods: Considering the radiation therapy structures' geometric attributes (centroid, volume, and shape), the spatial relationship of neighboring structures, as well as anatomical similarity of individual contours among patients, the authors established GAD models to characterize the interstructural centroid and volume variations, and the intrastructural shape variations of each individual structure. The GAD models are scalable and deformable, and constrained by their respective principal attribute variations calculated from training sets with verified OAR contours. A new iterative weighted GAD model-fitting algorithm was developed for contouring error detection. Receiver operating characteristic (ROC) analysis was employed in a unique way to optimize the model parameters to satisfy clinical requirements. A total of forty-four head-and-neck patient cases, each of which includes nine critical OAR contours, were utilized to demonstrate the proposed strategy. Twenty-nine out of these forty-four patient cases were utilized to train the inter-and intrastructural GAD models. These training data and the remaining fifteen testing data sets were separately employed to test the effectiveness of the proposed contouring error detection strategy. Results: An evaluation tool was implemented to illustrate how the proposed strategy automatically detects the radiation therapy contouring errors for a given patient and provides 3D graphical visualization of error detection results as well. The contouring error detection results were achieved with an average sensitivity of 0.954/0.906 and an average specificity of 0.901/0.909 on the centroid/volume related contouring errors of all the tested samples. As for the detection results on structural shape related contouring errors, an average sensitivity of 0.816 and an average specificity of 0.94 on all the tested samples were obtained. The promising results indicated the feasibility of the proposed strategy for the detection of contouring errors with low false detection rate. Conclusions: The proposed strategy can reliably identify contouring errors based upon inter-and intrastructural constraints derived from clinically approved contours. It holds great potential for improving the radiation therapy workflow. ROC and box plot analyses allow for analytically tuning of the system parameters to satisfy clinical requirements. Future work will focus on the improvement of strategy reliability by utilizing more training sets and additional geometric attribute constraints. (C) 2015 American Association of Physicists in Medicine.
引用
收藏
页码:1048 / 1059
页数:12
相关论文
共 10 条
  • [1] A Methodology for Generating Numerical Phantoms for Radiation Therapy Using Geometric Attribute Distribution Models
    Dolly, S.
    Chen, H.
    Mutic, S.
    Anastasio, M.
    Li, H.
    MEDICAL PHYSICS, 2016, 43 (06) : 3877 - 3878
  • [2] Automated OAR Anomaly and Error Detection Tool in Radiation Therapy
    Hui, C. B.
    Nourzadeh, H.
    Watkins, W. T.
    Trifiletti, D. M.
    Alonso, C.
    Dutta, S. W.
    Siebers, J. V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E554 - E555
  • [3] The effect of geometric error on dose distribution in intraoperative radiation therapy (IORT) with INTRABEAM
    Nasir, Z.
    Nwankwo, O.
    Schneider, F.
    Clausen, S.
    Glatting, G.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S169 - S169
  • [4] Clinical Validation of An Automated Treatment Error Detection Software for Radiation Therapy
    Yaddanapudi, S.
    Wang, D.
    Kim, Y.
    Xia, J.
    MEDICAL PHYSICS, 2019, 46 (06) : E415 - E416
  • [5] Graph-based risk assessment and error detection in radiation therapy
    Munbodh, Reshma
    Bowles, Juliana K.
    Zaveri, Hitten P.
    MEDICAL PHYSICS, 2021, 48 (03) : 965 - 977
  • [6] A general strategy for geometric error identification of multi-axis machine tools based on point measurement
    Zhang, Zhenjiu
    Hu, Hong
    INTERNATIONAL JOURNAL OF ADVANCED MANUFACTURING TECHNOLOGY, 2013, 69 (5-8): : 1483 - 1497
  • [7] A general strategy for geometric error identification of multi-axis machine tools based on point measurement
    Zhenjiu Zhang
    Hong Hu
    The International Journal of Advanced Manufacturing Technology, 2013, 69 : 1483 - 1497
  • [8] Generic Approach for Security Error Detection Based on Learned System Behavior Models for Automated Security Tests
    Schanes, Christian
    Huebler, Andreas
    Fankhauser, Florian
    Grechenig, Thomas
    IEEE SIXTH INTERNATIONAL CONFERENCE ON SOFTWARE TESTING, VERIFICATION AND VALIDATION WORKSHOPS (ICSTW 2013), 2013, : 453 - 460
  • [9] Automated Organ Segmentation for Radiation Therapy: A Comparative Analysis of AI-Based Tools Versus Manual Contouring in Korean Cancer Patients
    Choi, Seo Hee
    Park, Jong Won
    Cho, Yeona
    Yang, Gowoon
    Yoon, Hong In
    CANCERS, 2024, 16 (21)
  • [10] TOWARDS EXPERIMENTAL-VERIFICATION OF AN AUTOMATED COMPLIANT MOTION PLANNER BASED ON A GEOMETRIC-THEORY OF ERROR-DETECTION AND RECOVERY
    JENNINGS, J
    DONALD, B
    CAMPBELL, D
    PROCEEDINGS - 1989 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOL 1-3, 1989, : 632 - 637