Comparison of the Repeatability of Echocardiographic Measurements from Different Modes and Views in Horses of Various Breeds and Sizes

被引:4
|
作者
Al Haidar, Ali [1 ]
Farnir, Frederic [2 ]
Deleuze, Stefan [1 ]
Sandersen, Charlotte [1 ]
Amory, H. [1 ]
机构
[1] Univ Liege, Fac Vet Med, Clin Dept Compan Anim & Equips, Equine Teaching Hosp, B-4000 Liege, Belgium
[2] Univ Liege, Fac Vet Med, Dept Anim Prod, B-4000 Liege, Belgium
关键词
Echocardiography; Repeatability; 2; D-mode; M-mode; Doppler measurements; TO-DAY VARIABILITY; CARDIAC-FUNCTION; 2-DIMENSIONAL ECHOCARDIOGRAPHY; DIMENSIONS; ACEPROMAZINE; DETOMIDINE;
D O I
10.1016/j.jevs.2010.04.004
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
The objective of this study was to compare the repeatability of echocardiographic measurements obtained from different echocardiographic modes and views in healthy adult equids of various sizes, breeds, and thorax shapes. Ten equids (body weight: 120-662 kg; age: 1-26 years) from various breeds, free of cardiac disease, were used in this study. Each animal was submitted to a standardized echocardiographic and Doppler protocol 3 times at 1 day interval. This protocol included the measurements of left and right ventricular, aortic, pulmonary, and left atrial parameters obtained from different views using the bidimensional (2D) or the motion (M) modes, and the measurement of several parameters of blood flow obtained from the pulsed wave Doppler mode. Repeatability of each measurement was estimated on the basis of the residual variance using a linear model and the coefficient of variation of repeated measurements. A two by two comparison of the repeatability of measurements performed in different views was performed using the residual variances in a variance ratio F test. Results showed that repeatability of echocardiographic or Doppler measurements in equids of various sizes, breeds, and thorax shapes are comparable to previously reported results in thoroughbred and standard-bred horses. Left ventricular morphologic parameters showed a good repeatability in the classic M-mode right parasternal short axis view at the level of the chordae tendineae, but the 2D-mode right parasternal long axis four-chamber view appeared to offer an interesting alternative measurement. This latter view also allowed obtaining the Most repeatable measurement of right ventricular internal diameter. The left atrial diameter was maximal and most. repeatable in the 2D-mode left parasternal long axis four-chamber angled view, and the repeatability of the aortic diameter was best in the 2D-mode,right parasternal long axis five-chamber view. Finally, aortic systolic time intervals were more repeatable when measured from the Doppler mode as compared with the M-mode. In conclusion, repeatability of echocardiographic measurements in horses could be optimized after the following protocol: (1) M-mode right parasternal short axis view at the level of chordae tendineae to measure left ventricular morphologic parameters, and 2D-mode right parasternal long axis four-chamber as an alternative view; (2) 2D-mode right parasternal long axis five-chambers to measure the aortic diameter; (3) 2D-mode left parasternal long axis four-chambers angled view to measure the left atrial diameter.
引用
收藏
页码:287 / 297
页数:11
相关论文
共 50 条
  • [1] Repeatability of standard transthoracic echocardiographic measurements in horses
    Kriz, NG
    Rose, RJ
    AUSTRALIAN VETERINARY JOURNAL, 2002, 80 (06) : 362 - 370
  • [2] Reproducibility and repeatability of M-mode echocardiographic measurements collected from 25 normal horses
    Sampson, SN
    Jacobson, RL
    Sande, RD
    Susumi, CJ
    Larntz, KJ
    Tucker, RL
    Bayly, WM
    JOURNAL OF EQUINE VETERINARY SCIENCE, 1999, 19 (01) : 51 - 57
  • [3] Comparison of echocardiographic measurements in elite and nonelite Arabian endurance horses
    Sleeper, Meg M.
    Durando, Mary M.
    Holbrook, Todd C.
    Payton, Mark E.
    Birks, Eric K.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2014, 75 (10) : 893 - 898
  • [4] Comparison of body measurements of beef cows of different breeds
    Bene, Szabolcs
    Nagy, Barnabas
    Nagy, Lajos
    Kiss, Balakzs
    Polgar, J. Peter
    Szabo, Ferenc
    ARCHIV FUR TIERZUCHT-ARCHIVES OF ANIMAL BREEDING, 2007, 50 (04): : 363 - 373
  • [5] Morphometric measurements of flexor tendons and ligaments in Arabian horses by ultrasonographic examination and comparison with other breeds
    Çelimli, N
    Seyrek-Intas, D
    Kaya, M
    EQUINE VETERINARY EDUCATION, 2004, 16 (02) : 81 - 85
  • [6] Echocardiographic evaluation of cardiac development of athletic horses: comparison between different physical activities
    Bonomo, Carolina C. M.
    Michima, Lilian E. S.
    Miyashiro, Patricia
    Fernandes, Wilson Roberto
    PESQUISA VETERINARIA BRASILEIRA, 2014, 34 (09): : 923 - 927
  • [7] COMPARISON OF OVOMUCOIDS ISOLATED FROM DIFFERENT BREEDS OF CHICKENS
    STEVENS, L
    SCOTT, R
    DUNCAN, D
    BRITISH POULTRY SCIENCE, 1986, 27 (01) : 160 - 160
  • [8] Comparison of femoral inclination angle measurements in dysplastic and nondysplastic dogs of different breeds
    Sarierler, M
    ACTA VETERINARIA HUNGARICA, 2004, 52 (02) : 245 - 252
  • [9] A COMPARISON OF ECHOCARDIOGRAPHIC INDEXES OF THE NONRACING, HEALTHY GREYHOUND TO REFERENCE VALUES FROM OTHER BREEDS
    SNYDER, PS
    SATO, T
    ATKINS, CE
    VETERINARY RADIOLOGY & ULTRASOUND, 1995, 36 (05) : 387 - 392
  • [10] Different modes of arc attachment at HID cathodes: simulation and comparison with measurements
    Dabringhausen, L
    Langenscheidt, O
    Lichtenberg, S
    Redwitz, M
    Mentel, J
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2005, 38 (17) : 3128 - 3142