Butterfly-Shaped Conjugated Oligoelectrolyte/Graphene Oxide Integrated Assay for Light-Up Visual Detection of Heparin

被引:103
|
作者
Cai, Liping [1 ]
Zhan, Ruoyu [1 ]
Pu, Kan-Yi [1 ]
Qi, Xiaoying [2 ]
Zhang, Hua [2 ]
Huang, Wei [3 ,4 ]
Liu, Bin [1 ]
机构
[1] Natl Univ Singapore, Dept Chem & Biomol Engn, Singapore 117576, Singapore
[2] Nanyang Technol Univ, Sch Mat Sci & Engn, Singapore 639798, Singapore
[3] Nanjing Univ Posts & Telecommun, Key Lab Organ Elect & Informat Displays, Nanjing 210046, Peoples R China
[4] Singapore Jiangsu Joint Res Ctr Organ Bio Elect I, Singapore, Singapore
基金
中国国家自然科学基金;
关键词
REDUCED GRAPHENE OXIDE; NONCOVALENT SIDEWALL-FUNCTIONALIZATION; POLYHEDRAL OLIGOMERIC SILSESQUIOXANE; WALLED CARBON NANOTUBES; MERCURY ION DETECTION; SENSING BIOMOLECULES; FLUORESCENT SENSORS; ENERGY-TRANSFER; GRAPHITE OXIDE; DNA;
D O I
10.1021/ac2016135
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A water-soluble pyrene-based butterfly shaped conjugated oligoelectrolyte (TFP) is synthesized and integrated with graphene oxide (GO) to form a label-free assay for heparin detection. Efficient fluorescence quenching occurs between TFP and GO because of strong electrostatic and pi-pi interactions, leading to nearly dark emission in the absence of analytes. Addition of heparin into TFP solution significantly minimizes the fluorescence quenching of GO toward TFP, which is less effective for the heparin analogues, such as hyaluronic acid and chondroitin 4-sulfate. As a consequence, the solution emits strong yellow fluorescence only in the presence of heparin, which allows for light-up visual discrimination of heparin from its analogues. Moreover, the linear light-up response of the TFP/GO integrated assay enables heparin quantification in the range of 0-1.76 U/mL with a limit of detection of 0.046 U/mL, which is practical for heparin monitoring during postoperative and long-term care. This study thus demonstrates a new synthetic strategy to develop GO based chemical and biological sensing without the employment of dye-labeled biomolecules.
引用
收藏
页码:7849 / 7855
页数:7
相关论文
共 3 条
  • [1] Graphene oxide assisted light-up aptamer selection against Thioflavin T for label-free detection of microRNA
    Islam, Md Mamunul
    Ghielmetti, Victoria Michele
    Allen, Peter B.
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [2] Graphene oxide assisted light-up aptamer selection against Thioflavin T for label-free detection of microRNA
    Md Mamunul Islam
    Victoria Michele Ghielmetti
    Peter B. Allen
    Scientific Reports, 11
  • [3] A smartphone-integrated light-up lanthanide fluorescent probe for the visual and ratiometric detection of total phosphorus in human urine and environmental water samples
    Wu, Huifang
    Ling, Yuwei
    Ju, Shiying
    Chen, Yubing
    Xu, Mengqi
    Tang, Yanfeng
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 279