Fit-for-Purpose Assessment of QuEChERS LC-MS/MS Methods for Environmental Monitoring of Organotin Compounds in the Bottom Sediments of the Odra River Estuary

被引:3
|
作者
Kucharski, Dawid [1 ]
Stasiuk, Robert [2 ]
Drzewicz, Przemyslaw [3 ]
Skowronek, Artur [4 ]
Strzelecka, Agnieszka [4 ]
Mianowicz, Kamila [5 ]
Giebultowicz, Joanna [1 ]
机构
[1] Med Univ Warsaw, Fac Pharm, Dept Bioanal & Drugs Anal, Banacha 1, PL-02097 Warsaw, Poland
[2] Univ Warsaw, Fac Biol, Inst Microbiol, Dept Geomicrobiol, Miecznikowa 1, PL-02096 Warsaw, Poland
[3] Polish Geol Inst, Natl Res Inst, Rakowiecka 4, PL-00975 Warsaw, Poland
[4] Univ Szczecin, Inst Marine & Environm Sci, Mickiewicza 16, PL-70383 Szczecin, Poland
[5] Interoceanmet Joint Org, Cyryla & Metodego 9, PL-71541 Szczecin, Poland
来源
MOLECULES | 2022年 / 27卷 / 15期
关键词
bottom sediments; environmental monitoring; Odra River estuary; organotin compounds; trueness; verification; PERFORMANCE LIQUID-CHROMATOGRAPHY; BALTIC COASTAL ZONE; BUTYLTIN COMPOUNDS; SPECIATION; WATER; SAMPLES; TRENDS;
D O I
10.3390/molecules27154847
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
Organotin compounds (OTCs) are among the most hazardous substances found in the marine environment and can be determined by either the ISO 23161 method based on extraction with non-polar organic solvents and gas chromatography analysis or by the recently developed QuEChERS method coupled to liquid chromatography-mass spectrometry (LC-MS/MS). To date, the QuEChERS LC/MS and ISO 23161 methods have not been compared in terms of their fit-for-purpose and reliability in the determination of OTCs in bottom sediments. In the case of ISO 23161, due to a large number of interferences gas chromatography-mass spectrometry was not suitable for the determination of OTCs contrary to more selective determination by gas chromatography with an atomic emission detector. Moreover, it has been found that the derivatization of OTCs to volatile compounds, which required prior gas chromatography determination, was strongly affected by the sediments' matrices. As a result, a large amount of reagent was needed for the complete derivatization of the compounds. Contrary to ISO 23161, the QuEChERS LC-MS/MS method did not require the derivatization of OTC and is less prone to interferences. Highly volatile and toxic solvents were not used in the QuEChERS LC-MS/MS method. This makes the method more environmentally friendly according to the principles of green analytical chemistry. QuEChERS LC-MS/MS is suitable for fast and reliable environmental monitoring of OTCs in bottom sediments from the Odra River estuary. However, determination of di- and monobutyltin by the QuEChERS LC-MS/MS method was not possible due to the constraints of the chromatographic system. Hence, further development of this method is needed for monitoring di- and monobutyltin in bottom sediments.
引用
收藏
页数:12
相关论文
共 21 条
  • [1] Fit-for-Purpose methods for mycotoxin analysis using LC-MS
    Zhang, Kai
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2017, 254
  • [2] Fit-for-Purpose Mycotoxin Methods Using Rapid and LC-MS Techniques
    Zhang, Kai
    Trucksess, Mary W.
    JOURNAL OF AOAC INTERNATIONAL, 2018, 101 (03) : 607 - 608
  • [3] Fit-for-purpose bioanalytical cross-validation for LC-MS/MS assays in clinical studies
    Xu, Xiaohui
    Ji, Qin C.
    Jemal, Mohammed
    Gleason, Carol
    Shen, Jim X.
    Stouffer, Bruce
    Arnold, Mark E.
    BIOANALYSIS, 2013, 5 (01) : 83 - 90
  • [4] Development and fit-for-purpose validation of a LC-MS/MS assay for fibrinogen peptide A quantitation in human plasma
    Lin, Mingxiang
    Lassman, Michael E.
    Weiner, Russell
    Laterza, Omar F.
    BIOANALYSIS, 2014, 6 (13) : 1759 - 1766
  • [5] A fit-for-purpose LC-MS/MS method for the analysis of selected Streptococcal quorum sensing peptides in human saliva
    Verbeke, Frederick
    Van der Borght, Kevin
    De Spiegeleer, Anton
    Debunne, Nathan
    Janssens, Yorick
    Wynendaele, Evelien
    De Spiegeleer, Bart
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2022, 213
  • [6] Fit-for-purpose biomarker LC-MS/MS qualification for the quantitation of very long chain fatty acids in human cerebrospinal fluid
    Williams, John
    Zhu, Kan
    Crampon, Eric
    Iffland, Andre
    BIOANALYSIS, 2020, 12 (03) : 143 - 158
  • [7] Fit-for-purpose LC-MS/MS quantification of leukotoxin and leukotoxin diol in mouse plasma without sample pre-concentration
    Savaryn, John Paul
    Qiu, Xiazi
    Duignan, B. David
    Goess, Christian
    Osman, Sami
    Ji, C. Qin
    Jenkins, Gary
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2021, 1180
  • [8] Determination of fungicide residues in soil using QuEChERS coupled with LC-MS/MS, and environmental risk assessment
    Burak Polat
    Osman Tiryaki
    Environmental Monitoring and Assessment, 2023, 195
  • [9] Determination of fungicide residues in soil using QuEChERS coupled with LC-MS/MS, and environmental risk assessment
    Polat, Burak
    Tiryaki, Osman
    ENVIRONMENTAL MONITORING AND ASSESSMENT, 2023, 195 (08)
  • [10] Challenges and stepwise fit-for-purpose optimization for bioanalyses of remdesivir metabolites nucleotide monophosphate and triphosphate in mouse tissues using LC-MS/MS
    Hu, Wenjuan
    Chang, Lu
    Ke, Changqiang
    Xie, Yuanchao
    Shen, Jingshan
    Tan, Bo
    Liu, Jia
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2021, 194