Assessment of uterine artery geometry and hemodynamics in human pregnancy with 4d flow mri and its correlation with doppler ultrasound

被引:18
|
作者
Hwuang, Eileen [1 ]
Vidorreta, Marta [2 ,3 ]
Schwartz, Nadav [4 ]
Moon, Brianna F. [1 ]
Kochar, Kirpal [5 ]
Tisdall, Matthew Dylan [6 ]
Detre, John A. [3 ,6 ]
Witschey, Walter R. T. [6 ]
机构
[1] Univ Penn, Dept Bioengn, Philadelphia, PA 19104 USA
[2] Siemens Healthineers, Tarrytown, NY USA
[3] Hosp Univ Penn, Dept Neurol, 3400 Spruce St, Philadelphia, PA 19104 USA
[4] Hosp Univ Penn, Dept Obstet & Gynecol, Philadelphia, PA 19104 USA
[5] Drexel Univ, Coll Med, Philadelphia, PA 19104 USA
[6] Hosp Univ Penn, Dept Radiol, 3400 Spruce St, Philadelphia, PA 19104 USA
基金
美国国家科学基金会;
关键词
phase contrast; uterine artery Doppler; 4D flow; preeclampsia; intrauterine growth restriction; pregnancy; PHASE-CONTRAST MRI; BLOOD-FLOW; GESTATIONAL-AGE; WOMEN; FETAL; QUANTIFICATION; PATIENT; WEIGHT;
D O I
10.1002/jmri.26229
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background Uterine artery (UtA) hemodynamics might be used to predict risk of hypertensive pregnancy disorders, including preeclampsia and intrauterine growth restriction. Purpose or Hypothesis To determine the feasibility of 4D flow MRI in pregnant subjects by characterizing UtA anatomy, computing UtA flow, and comparing UtA velocity, and pulsatility and resistivity indices (PI, RI) with transabdominal Doppler ultrasound (US). Study Type Prospective cross-sectional study from June 6, 2016, to May 2, 2018. Population or Subjects or Phantom or Specimen or Animal Model Forty-one singleton pregnant subjects (age [range] = 27.0 +/- 5.9 [18-41] years) in their second or third trimester. We additionally scanned three subjects who had prepregnancy diabetes or chronic hypertension. Field Strength/Sequence The subjects underwent UtA and placenta MRI using noncontrast angiography and 4D flow at 1.5T. Assessment UtA anatomy was described based on 4D flow-derived noncontrast angiography, while UtA flow properties were characterized by net flow, systolic/mean/diastolic velocity, PI and RI through examination of 4D flow data. PI and RI are standard hemodynamic parameters routinely reported on Doppler US. Statistical Tests Spearman's rank correlation, Wilcoxon signed rank tests, and Bland-Altman plots were used to preliminarily investigate the relationships between flow parameters, gestational age, and Doppler US. or Results 4D flow MRI and UtA flow quantification was feasible in all subjects. There was considerable heterogeneity in UtA geometry in each subject between left and right UtAs and between subjects. Mean 4D flow-based parameters were: mean bilateral flow rate = 605.6 +/- 220.5 mL/min, PI = 0.72 +/- 0.2, and RI = 0.47 +/- 0.1. Bilateral flow did not change with gestational age. We found that MRI differed from US in terms of lower PI (mean difference -0.1) and RI (mean difference < -0.1) with Wilcoxon signed rank test P = 0.05 and P = 0.13, respectively. Data Conclusion 4D flow MRI is a feasible approach for describing UtA anatomy and flow in pregnant subjects. Level of Evidence: Technical Efficacy: Stage 1 J. Magn. Reson. Imaging 2019;49:59-68.
引用
收藏
页码:59 / 68
页数:10
相关论文
共 50 条
  • [1] Cerebral Hemodynamics Comparison between Transcranial Doppler Ultrasound and 4D Flow MRI
    Fico, Brandon
    Miller, Kathleen
    Rivera-Rivera, Leonardo
    Corkery, Adam
    Pearson, Andrew
    Loggie, Nicole
    Howery, Anna
    Rowley, Howard
    Johnson, Kevin
    Johnson, Sterling
    Weiben, Oliver
    Barnes, Jill
    PHYSIOLOGY, 2023, 38
  • [2] Cerebral hemodynamics comparison using transcranial doppler ultrasound and 4D flow MRI
    Fico, Brandon G.
    Miller, Kathleen B.
    Rivera-Rivera, Leonardo A.
    Corkery, Adam T.
    Pearson, Andrew G.
    Loggie, Nicole A.
    Howery, Anna J.
    Rowley, Howard A.
    Johnson, Kevin M.
    Johnson, Sterling C.
    Wieben, Oliver
    Barnes, Jill N.
    FRONTIERS IN PHYSIOLOGY, 2023, 14
  • [3] CHILDREN - Fetal 4D Flow MRI with Doppler Ultrasound Gating
    不详
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2023, : 771 - 771
  • [4] Cross-modality and in-vivo validation of 4D flow MRI evaluation of uterine artery blood flow in human pregnancy
    Hwuang, E.
    Wu, P. H.
    Rodriguez-Soto, A.
    Langham, M.
    Wehrli, F. W.
    Vidorreta, M.
    Moon, B.
    Kochar, K.
    Parameshwaran, S.
    Koelper, N.
    Tisdall, M. D.
    Detre, J. A.
    Witschey, W.
    Schwartz, N.
    ULTRASOUND IN OBSTETRICS & GYNECOLOGY, 2021, 58 (05) : 722 - 731
  • [5] 4D flow MRI for intracranial hemodynamics assessment in Alzheimer's disease
    Rivera-Rivera, Leonardo A.
    Turski, Patrick
    Johnson, Kevin M.
    Hoffman, Carson
    Berman, Sara E.
    Kilgas, Phillip
    Rowley, Howard A.
    Carlsson, Cynthia M.
    Johnson, Sterling C.
    Wieben, Oliver
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2016, 36 (10): : 1718 - 1730
  • [6] Assessment of mean pulmonary artery pressure with 4D flow MRI
    Crowe, L.
    Guglielmi, G.
    Hachulla, A. -L.
    Noble, S.
    Soccal, P. M.
    Beghetti, M.
    Lador, F.
    Vallee, J. -P.
    CHEST, 2017, 151 (05) : 117A - 117A
  • [7] Assessment of Flow and Hemodynamics in the Carotid Artery Using a Reduced TE 4D Flow Spiral Phase-Contrast MRI
    Kadbi, Mo
    Negandar, Mj
    Traughber, Melanie
    Martin, Peter
    Amini, Amir A.
    2013 35TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2013, : 1100 - 1103
  • [8] Cerebral Sinus Hemodynamics in Adults Revealed by 4D Flow MRI
    Dai, Chihang
    Zhao, Pengfei
    Ding, Heyu
    Lv, Han
    Qiu, Xiaoyu
    Tang, Ruowei
    Xu, Ning
    Huang, Yan
    Han, Xu
    Yang, Zhenghan
    Wang, Zhenchang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2024, 60 (04) : 1706 - 1717
  • [9] AUTOMATIC TOOL FOR PULMONARY ARTERY HEMODYNAMIC ASSESSMENT FROM 4D FLOW MRI
    Bobeda, Javier
    Erostarbe, Haizea
    Stephens, Maialen
    Gaitan, Angel
    Kumar, Rahul
    Nuche, Jorge
    Marco, Irene
    Delgado, Juan
    Ruiz-Cabello, Jesus
    Lopez-Linares, Karen
    2023 IEEE 20TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING, ISBI, 2023,
  • [10] The value of 4D flow MRI in cardiac assessment
    Nicholls, Mark
    EUROPEAN HEART JOURNAL, 2022, 43 (10) : 930 - 932