A systematic review on clinical implication of continuous glucose monitoring in diabetes management

被引:14
|
作者
Azhar, Anam [1 ]
Gillani, Syed W. [1 ]
Mohiuddin, Ghasna [1 ]
Majeed, Rukhsar A. [1 ]
机构
[1] Gulf Med Univ, Coll Pharm, Dept Pharm Practice, AL JURF 1 Rashid Al Khadar St, Ajman, U Arab Emirates
来源
关键词
Continuous glucose monitoring; diabetes mellitus; estimated A1c; glycated hemoglobin; type 1 diabetes mellitus; type 2 diabetes mellitus; ASSOCIATION;
D O I
10.4103/jpbs.JPBS_7_20
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Objective: The aim of this systematic review was to evaluate the clinical implications of continuous glucose monitoring (CGM) among patients with diabetes mellitus using variables that include glycated hemoglobin (HbA1c), estimated A1c, glucose variability, and users' perspectives. Materials and Methods: This study analyzed 17 articles that were identified and studied according to the research question criteria. PRISMA guidelines were used for identification and screening of the literature. The required data were searched using Medscape, PubMed, PROSPERO, Wiley Library, Scopus, Clinical Trial Registry, and Trip. Results: The articles reviewed were on the use of CGM in type 1 and type 2 diabetes mellitus, which showed significant improvement in the levels of HbA1c as compared to non-CGM. The application of CGM on acute sudden onset type of adverse drug reactions (i.e., hypoglycemia) is better than fasting blood sugar or self-monitoring of blood glucose or capillary blood glucose (random blood glucose monitoring). CGM is beneficial for use in patients with type 2 diabetes mellitus including elderly patients as it gives information regarding glucose variability as well as HbA1c levels. The health-care providers require full spectrum of patients' CGM data to design a better therapeutic plan. However, the patients experienced inconvenience on wearing the device on the body for longer periods. The findings also stated the fact that more education and training is required for the patients to interpret their own glycemic data using CGM and modify their lifestyle accordingly. Use of CGM along with HbA1c has also been used to achieve better glycemic results and it allows the health care professional to guide patients in terms of their glucose level; whether they are hypoglycemic or hyperglycemic, however its use has some controversies that minimize its application. Conclusion: The study concluded that CGM has significant potential in the management of not only patients with type 1 diabetes mellitus but also patients with type 2 diabetes mellitus in spite of the few limitations that are being improvised in the upcoming years. However, limited literature of CGM among patients with type 2 diabetes mellitus and pregnant women reduces the practice scope.
引用
收藏
页码:102 / 111
页数:10
相关论文
共 50 条
  • [1] Continuous Glucose Monitoring: Review of an Innovation in Diabetes Management
    Mian, Zainab
    Hermayer, Kathie L.
    Jenkins, Alicia
    AMERICAN JOURNAL OF THE MEDICAL SCIENCES, 2019, 358 (05): : 332 - 339
  • [2] Implementation Strategies for Inpatient Continuous Glucose Monitoring-based Diabetes Management: A Systematic Review
    Olsen, Mikkel T.
    Liarakos, Alexandros L.
    Wilmot, Emma G.
    Dhatariya, Ketan
    Thabit, Hood
    Sanchez-Garcia, David
    Norgaard, Kirsten
    Pedersen-Bjergaard, Ulrik
    Hansen, Katrine B.
    Vangoitsenhoven, Roman
    Mathieu, Chantal
    Kristensen, Peter L.
    Mader, Julia K.
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2025,
  • [3] Continuous Glucose Monitoring Sensors for Diabetes Management: A Review of Technologies and Applications
    Cappon, Giacomo
    Vettoretti, Martina
    Sparacino, Giovanni
    Facchinetti, Andrea
    DIABETES & METABOLISM JOURNAL, 2019, 43 (04) : 383 - 397
  • [4] Role of continuous glucose monitoring in diabetes management
    Moser, E. G.
    Crew, L. B.
    Garg, S. K.
    AVANCES EN DIABETOLOGIA, 2010, 26 (02): : 73 - 78
  • [5] Clinical and economic outcomes of continuous glucose monitoring system (CGMS) in patients with diabetes mellitus: A systematic literature review
    Aggarwal, Aditi
    Pathak, Smit
    Goyal, Richa
    DIABETES RESEARCH AND CLINICAL PRACTICE, 2022, 186
  • [6] Does continuous glucose monitoring have clinical utility in contemporary management of diabetes?
    Cameron, FJ
    Ambler, GR
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2004, 40 (03) : 79 - 84
  • [7] A comparison of continuous glucose monitors (CGMs) in diabetes management: A systematic literature review
    Edward, Rosilla
    Priefer, Ronny
    PRIMARY CARE DIABETES, 2023, 17 (06) : 529 - 534
  • [8] Continuous glucose monitoring versus self-monitoring of blood glucose in the management of cystic fibrosis related diabetes: A systematic review and meta-analysis
    Kumar, Shanal
    Soldatos, Georgia
    Ranasinha, Sanjeeva
    Teede, Helena
    Pallin, Michael
    JOURNAL OF CYSTIC FIBROSIS, 2023, 22 (01) : 39 - 49
  • [9] Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes
    Nalinee Poolsup
    Naeti Suksomboon
    Aye Mon Kyaw
    Diabetology & Metabolic Syndrome, 5
  • [10] Systematic review and meta-analysis of the effectiveness of continuous glucose monitoring (CGM) on glucose control in diabetes
    Poolsup, Nalinee
    Suksomboon, Naeti
    Kyaw, Aye Mon
    DIABETOLOGY & METABOLIC SYNDROME, 2013, 5