Megavoltage radiation dose response of digital computed radiography

被引:0
|
作者
Wang, ZH [1 ]
Wu, QRJ [1 ]
Sibata, CH [1 ]
机构
[1] Case Western Reserve Univ, Sch Med, Dept Radiat Oncol, Cleveland, OH 44106 USA
来源
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING | 2001年 / 4320卷
关键词
D O I
10.1117/12.430958
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The response of a digital computed radiography system to the megavoltage therapeutic radiation beams was invested. A narrow slit of radiation beam was used to test the line spread function of the system. The effects of various facts such as cassette, beam energy, radiation dose, scanning orientation and timing on the line spread function were investigated. The calibration curves were established to calibrate the image intensity to the megavoltage radiation dose. The calibration curves were applied to measure the beam profiles of the radiation fields with various wedges.
引用
收藏
页码:236 / 243
页数:8
相关论文
共 50 条
  • [1] Radiostereometric analysis: comparison of radiation dose and precision in digital and computed radiography
    Jorgensen, Peter Bo
    Krag-Nielsen, Nicolai
    Lindgren, Lars
    Morup, Rikke Margrethe Staghoj
    Kaptein, Bart
    Stilling, Maiken
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 143 (09) : 5919 - 5926
  • [2] Radiostereometric analysis: comparison of radiation dose and precision in digital and computed radiography
    Peter Bo Jørgensen
    Nicolai Krag-Nielsen
    Lars Lindgren
    Rikke Margrethe Staghøj Mørup
    Bart Kaptein
    Maiken Stilling
    Archives of Orthopaedic and Trauma Surgery, 2023, 143 : 5919 - 5926
  • [3] Optimization of Dose and Image Quality for Computed Radiography and Digital Radiography
    John E. Aldrich
    Emerenciana Duran
    Pat Dunlop
    John R. Mayo
    Journal of Digital Imaging, 2006, 19 : 126 - 131
  • [4] Optimization of dose and image quality for computed radiography and digital radiography
    Aldrich, JE
    Duran, E
    Dunlop, P
    Mayo, JR
    JOURNAL OF DIGITAL IMAGING, 2006, 19 (02) : 126 - 131
  • [5] DIGITAL RADIOGRAPHY: IMAGE QUALITY AND RADIATION DOSE
    Seibert, J. Anthony
    HEALTH PHYSICS, 2008, 95 (05): : 586 - 598
  • [6] Slot-Scan Digital Radiography of the Lower Extremities: a Comparison to Computed Radiography with Respect to Image Quality and Radiation Dose
    Lee, Kwang Hwi
    Kwon, Jong Won
    Yoon, Young Cheol
    Choi, Sang-Hee
    Jung, Jee Young
    Kim, Ji Hye
    Lee, Sang Jun
    KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (01) : 51 - 57
  • [7] Radiation Dose from Megavoltage Cone Beam Computed Tomography for IGRT
    Kara, E.
    Dirican, B.
    Yazici, A.
    Hicsonmez, A.
    RADIOTHERAPY AND ONCOLOGY, 2017, 123 : S810 - S810
  • [8] Evaluation of a computed radiography system for megavoltage beam dosimetry
    Olch, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1885 - 1885
  • [9] Radiation dose reduction in direct digital panoramic radiography
    Gavala, Sophia
    Donta, Catherine
    Tsiklakis, Kostas
    Boziari, Argyro
    Kamenopoulou, Vasiliki
    Stamatakis, Harry C.
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 71 (01) : 42 - 48
  • [10] Management of pediatric radiation dose using Fuji computed radiography
    D.W. MacCutcheon
    Pediatric Radiology, 2004, 34 : S201 - S206