The impact of edema on planning 125I and 103Pd prostate implants

被引:53
|
作者
Yue, N
Dicker, AP
Nath, R
Waterman, FM
机构
[1] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
[2] Thomas Jefferson Univ, Jefferson Med Coll, Dept Radiat Oncol, Philadelphia, PA 19107 USA
关键词
brachytherapy; prostate implants; I-125; Pd-103; edema; dose evaluation; preimplant planning;
D O I
10.1118/1.598585
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Permanent transperineal interstitial I-125 and Pd-103 prostate implants are generally planned to deliver a specific dose to a clinically defined target volume; however, the post-implant evaluation usually reveals that the implant delivered a lower or higher dose than planned. This difference is generally attributed to such factors as source placement errors, overestimation of the prostate volume on CT, and post-implant edema. In the present work we investigate the impact of edema alone. In routine prostate implant planning, it is customary to assume that both the prostate and seeds are static throughout the entire treatment time, and post-implant edema is not taken into consideration in the dosimetry calculation. However, prostate becomes edematous after seed implantation, typically by 50% in volume [Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998)]. The edema resolves itself exponentially with a typical half-life of 10 days. In this work, the impact of the edema-induced dynamic change in prostate volume and seed location on the dose coverage of the prostate is investigated. The total dose delivered to the prostate was calculated by use of a dynamic model, which takes edema into account. In the model, the edema resolves exponentially with time, as reported in a separate study based on serial CT scans [Int. J. Radiat. Oncol., Biol., Phys. 41, 1069-1077 (1998)]. The model assumes that the seeds were implanted exactly as planned, thus eliminating the effect of source placement errors. Implants based on the same transrectal ultrasound (TRUS) images were planned using both I-125 and Pd-103 sources separately. The preimplant volume and planned seed locations were expanded to different degrees of edema to simulate the postimplant edematous prostate on day 0. The model calculated the dose in increments of 24 h, appropriately adjusting the prostate volume, seed locations, and source strength prior to each time interval and compiled dose-volume histograms (DVH) of the total dose delivered. A total of 30 such DVHs were generated for each implant using different combinations of edema half-life and magnitude. In addition, a DVH of the plan was compiled in the conventional manner, assuming that the prostate volume and seeds were static during treatment. A comparison of the DVH of the static model to the 30 edema corrected DVHs revealed that the plan overestimated the total dose by an amount that increased with the magnitude of the edema and the edema half-life. The maximum overestimation was 15% for I-125 and 32% for (103)pd. For more typical edema parameters (a 50% increase in volume and a 10 day half-life) the static plan for I-125 overestimated the total dose by about 5%, whereas that for Pd-103 overestimated it by about 12%. (C) 1999 American Association of Physicists in Medicine. [S0094-2405(99)00705-1].
引用
收藏
页码:763 / 767
页数:5
相关论文
共 50 条
  • [1] The impact of edema on planning 125I and 103Pd prostate implants
    Department of Therapeutic Radiology, Yale University School of Medicine, 333 Cedar Street, New Haven, CT 06510, United States
    不详
    Med. Phys., 5 (763-767):
  • [2] Rectal dose in 103PD and 125I permanent prostate implants
    Lief, EP
    Wang, X
    Cha, CM
    Potters, L
    RADIOLOGY, 1998, 209P : 157 - 157
  • [3] Dosimetric effects of seed anisotropy and interseed attenuation for 103Pd and 125I prostate implants
    Chibani, O
    Williamson, JF
    Todor, D
    MEDICAL PHYSICS, 2005, 32 (08) : 2557 - 2566
  • [4] Evaluation of the dose distribution for prostate implants using various 125I and 103Pd sources
    Meigooni, Ali S.
    Luerman, Christine M.
    Sowards, Keith T.
    MEDICAL PHYSICS, 2009, 36 (04) : 1452 - 1458
  • [5] Effect of Foley catheters on seed positions and urethral dose in 125I and 103Pd prostate implants
    Brezovich, IA
    Pareek, PN
    Duan, J
    Fiveash, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (05): : 1461 - 1468
  • [6] Anisotropy functions for 125I and 103Pd sources
    Weaver, K
    MEDICAL PHYSICS, 1998, 25 (12) : 2271 - 2278
  • [7] Optimum timing for image-based dose evaluation of 125I and 103PD prostate seed implants
    Yue, N
    Chen, Z
    Peschel, R
    Dicker, AP
    Waterman, FM
    Nath, R
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (04): : 1063 - 1072
  • [8] Edema-induced increase in tumour cell survival for 125I and 103Pd prostate permanent seed implants -: a bio-mathematical model
    Yue, N
    Chen, Z
    Nath, R
    PHYSICS IN MEDICINE AND BIOLOGY, 2002, 47 (07): : 1185 - 1204
  • [9] 125I RAPIDStrand versus 103Pd for localized prostate cancer: A dosimetric analysis
    Fagundes, H
    Keys, R
    Wojick, M
    Radden, M
    Bertelsman, C
    Cavanagh, W
    RADIOTHERAPY AND ONCOLOGY, 2004, 71 : S121 - S121
  • [10] Evaluated phantom material for 125I and 103Pd dosimetry
    Wallace, R
    MEDICAL PHYSICS, 2002, 29 (06) : 1201 - 1201