Analysis of ignition risk on mechanical equipment in ATEX

被引:0
|
作者
Petitfrere, Claire [1 ]
Proust, Christophe [1 ]
机构
[1] INERIS, F-60550 Verneuil En Halatte, France
关键词
ATEX; mechanical ignition source; non-electrical equipment;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Until the implementation of the ATEX directive 94/9/CE, the certification of equipment intended to explosive atmospheres was only dedicated to electrical equipment. Since the 1st July 2003, the non-electrical sources of inflammation are also to be looked at before putting an ATEX equipment on the market (pumps, couplers, reducing gears, ...) Among these sources, mechanical friction and impacts are a main cause of ignition of explosive atmosphere. The risk analysis of the equipment consists in considering the failures, which can lead to ignition. If the failure involves a friction between two parts or an impact, we shall estimate if this friction or impact dissipates a sufficient amount of energy to ignite the surrounding explosive atmosphere. As part of the European program MECHEX, we have studied the process of degradation of the mechanical energy into heat during friction and impacts and we have examined the mechanisms of ignition at the contact zone. An extensive experimental program is presented and some ''simple" modelling is proposed on purpose of practical applications. For frictional situations, a critical rubbing power is calculated without any limitations as for a potential lower boundary concerning the rubbing velocity. For "impacts", the relevant parameter for ignition is not the kinetic energy of the projectile but its velocity and the nature of the materials.
引用
收藏
页码:146 / 154
页数:9
相关论文
共 50 条
  • [1] Inspection, maintenance and repair of ATEX equipment
    Cottin, Olivier
    Lefebvre, Xavier
    PCIC EUROPE CONFERENCE RECORD, 2007, : 14 - 18
  • [2] Ignition tests for electrical and mechanical equipment subjected to hot surfaces
    Querol, E.
    Torrent, J. G.
    Bennett, D.
    Gummer, J.
    Fritze, J. -P.
    JOURNAL OF LOSS PREVENTION IN THE PROCESS INDUSTRIES, 2006, 19 (06) : 639 - 644
  • [3] Risk analysis in the frame of the ATEX Directive and the preparation of an Explosion Protection Document
    Pey, Alexis
    Suter, Georg
    Glor, Martin
    Lerena, Pablo
    Campos, Jordi
    SAFETY, RELIABILITY AND RISK ANALYSIS: THEORY, METHODS AND APPLICATIONS, VOLS 1-4, 2009, : 1217 - 1221
  • [4] Integration of HOFs into ATEX Risk Assessment Methodology
    Geng, Jie
    Mure, Salvina
    Camuncoli, Gianfranco
    Demichela, Micaela
    CISAP6: 6TH INTERNATIONAL CONFERENCE ON SAFETY & ENVIRONMENT IN PROCESS & POWER INDUSTRY, 2014, 36 : 583 - +
  • [5] IGNITION RISK ANALYSIS - CIGARETTE IGNITION OF UPHOLSTERED FURNITURE.
    Yeh, Kwan-nan
    Fire Technology, 1985, 21 (02) : 105 - 121
  • [6] OPERABILITY QUALIFICATION OF MECHANICAL EQUIPMENT BY ANALYSIS
    RATIU, MD
    BAK, WR
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1983, 44 : 444 - 445
  • [7] Failure analysis diagnosis of mechanical equipment
    Zhong, Qun-Peng
    Zhang, Zheng
    Tian, Yong-Jiang
    2002, Beijing University of Aeronautics and Astronautics (BUAA) (28): : 497 - 502
  • [8] The ATEX directive and fischbein's equipment for closing open-mouth bags
    Mpinga, Viviane
    Bontemps, René A.
    Powder Handling and Processing, 2006, 18 (03): : 180 - 181
  • [9] An ATEX-proof gamma tomography setup for measuring liquid distribution in process equipment
    Hoffmann, Rainer
    Koegl, Thilo
    FLOW MEASUREMENT AND INSTRUMENTATION, 2017, 53 : 147 - 153
  • [10] Effective Application of Ignition Risk Safety Analysis
    Benson, Rodney L.
    Kellner, Darryl W.
    2017 ANNUAL RELIABILITY AND MAINTAINABILITY SYMPOSIUM, 2017,