Evaluation of real-time QRS detection algorithms in variable contexts

被引:33
|
作者
Portet, F [1 ]
Hernández, AI [1 ]
Carrault, G [1 ]
机构
[1] Univ Rennes 1, Unite INSERM, Lab Traitement Signal & Image, Rennes, France
关键词
ECG analysis; QRS detection; algorithm evaluation; best algorithm selection; real-time signal monitoring;
D O I
10.1007/BF02345816
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
A method is presented to evaluate the detection performance of real-time QRS detection algorithms to propose a strategy for the adaptive selection of QRS detectors, in variable signal contexts. Signal contexts are defined as different combinations of QRS morphologies and clinical noise. Four QRS detectors are compared in these contexts by means of a multivariate analysis. This evaluation strategy is general and can be easily extended to a larger number of detectors. A set of morphology contexts, corresponding to eight QRS morphologies (normal, PVC, premature atrial beat, paced beat, LBBB, fusion, RBBB, junctional premature beat), was extracted from 17 standard ECG records. For each morphology context, the set of extracted beats, ranging from 30 to 23000, was resampled to generate 50 realisations of 20 concatenated beats. These realisations were then used as input to the QRS detectors, without noise, and with three different types of additive clinical noise (electrode motion artifact, muscle artifact, baseline wander) at three signal-to-noise ratios (5 dB, - 5 dB, - 15 dB). Performance was assessed by the number of errors, which reflected both false alarms and missed beats. The results show that the evaluated detectors are indeed complementary. For example, the Pan-Tompkins detector is the best in most contexts but the Okada detector generates fewer errors in the presence of electrode motion artifact. These results will be particularly useful to the development of a real-time system that will be able to choose the best QRS detector according to the current context.
引用
收藏
页码:379 / 385
页数:7
相关论文
共 50 条
  • [1] Evaluation of real-time QRS detection algorithms in variable contexts
    F. Portet
    A. I. Hernández
    G. Carrault
    Medical and Biological Engineering and Computing, 2005, 43 : 379 - 385
  • [2] Real-time QRS Detection Method
    Zheng, Huabin
    Wu, Jiankang
    2008 10TH IEEE INTERNATIONAL CONFERENCE ON E-HEALTH NETWORKING, APPLICATIONS AND SERVICES, 2008, : 169 - 170
  • [3] A REAL-TIME QRS DETECTION ALGORITHM
    PAN, J
    TOMPKINS, WJ
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1985, 32 (03) : 230 - 236
  • [4] Performance Evaluation of Real-Time Object Detection Algorithms
    Srisuk, Sanun
    Suwannapong, Chanwit
    Kitisriworapan, Songrit
    Kaewsong, Apiwut
    Ongkittikul, Surachai
    2019 7TH INTERNATIONAL ELECTRICAL ENGINEERING CONGRESS (IEECON 2019), 2019,
  • [5] Automated performance evaluation of real-time QRS-detection devices
    Suppappola, S.
    Sun, Y.
    Biomedical Instrumentation and Technology, 1995, 29 (01): : 41 - 49
  • [6] STRONG REAL-TIME QRS COMPLEX DETECTION
    Benosman, M. M.
    Bereksi-Reguig, F.
    Salerud, E. Goran
    JOURNAL OF MECHANICS IN MEDICINE AND BIOLOGY, 2017, 17 (08)
  • [7] A simple real-time QRS detection algorithm.
    Lee, J
    Jeong, K
    Yoon, J
    Lee, M
    PROCEEDINGS OF THE 18TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 18, PTS 1-5, 1997, 18 : 1396 - 1398
  • [8] ALGORITHMS FOR REAL-TIME TREND DETECTION
    NIEMINEN, A
    NEUVO, Y
    MITRA, U
    SIGNAL PROCESSING, 1989, 18 (01) : 1 - 15
  • [9] Low Power Electrocardiogram QRS Detection in Real-Time
    Ayari, E. Zoghlami
    Tielert, R.
    Wehn, N.
    13TH INTERNATIONAL CONFERENCE ON BIOMEDICAL ENGINEERING, VOLS 1-3, 2009, 23 (1-3): : 643 - +
  • [10] Microcontroller-based real-time QRS detection
    Sun, Y.
    Suppappola, S.
    Wrublewski, T.A.
    Biomedical Instrumentation and Technology, 1992, 26 (06): : 477 - 484