Biomechanical properties of human and porcine corneas

被引:199
|
作者
Elsheikh, Ahmed [1 ]
Alhasso, Daad [1 ]
Rama, Paolo [2 ]
机构
[1] Univ Dundee, Div Civil Engn, Dundee DD1 4HN, Scotland
[2] Hosp San Raffaele, Dept Ophthalmol, I-20132 Milan, Italy
关键词
corneal biomechanics; creep behaviour; stress-relaxation behaviour;
D O I
10.1016/j.exer.2008.02.006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The suitability of porcine corneas as approximate models for human corneas in mechanical property characterisation studies is experimentally assessed. Thirty seven human donor corneas and thirty four ex-vivo porcine corneas were tested under inflation conditions to determine their short-term stress-strain behaviour and long-term creep behaviour up to 2.8 h (10,000 s). Vertical strips extracted from further 12 human corneas and 10 porcine corneas were subjected to stress-relaxation tests for up to 20 min at different stress levels. Human and porcine corneas were observed to have almost the same form of behaviour under short and long-term loading. They both exhibited non-linear stress-strain behaviour and reacted to sustained loading in a similar fashion. However, human corneas were significantly stiffer than porcine corneas. They also crept less under long-term loading and could sustain their stress state for longer compared to porcine corneas. These differences, in addition to others identified earlier in relation to corneal mechanical anisotropy, cast doubt on the suitability of porcine corneas as models for human corneas in mechanical studies. (c) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:783 / 790
页数:8
相关论文
共 50 条
  • [1] Assessment of biomechanical properties of porcine corneas with air-puff swept source OCT
    Maczynska, Ewa Celina
    Karnowski, Karol Marian
    Kaluzny, Bartlomiej
    Grulkowski, Ireneusz
    Wojtkowski, Maciej D.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2016, 57 (12)
  • [2] BIOMECHANICAL PROPERTIES OF KERATOCONUS AND NORMAL CORNEAS
    ANDREASSEN, TT
    SIMONSEN, AH
    OXLUND, H
    EXPERIMENTAL EYE RESEARCH, 1980, 31 (04) : 435 - 441
  • [3] Biomechanical Evaluation of Response to Treatment with Human Decorin Core Protein in Ex-Vivo Human and Porcine Corneas
    Roberts, Cynthia J.
    Metzler, Kimberly M.
    Mahmoud, Ashraf M.
    Liu, Jun
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)
  • [4] An Indentation Technique to Characterize the Mechanical and Viscoelastic Properties of Human and Porcine Corneas
    Mark Ahearne
    Ying Yang
    Kong Y. Then
    Kuo-Kang Liu
    Annals of Biomedical Engineering, 2007, 35 : 1608 - 1616
  • [5] An indentation technique to characterize the mechanical and viscoelastic properties of human and porcine corneas
    Ahearne, Mark
    Yang, Ying
    Then, Kong Y.
    Liu, Kuo-Kang
    ANNALS OF BIOMEDICAL ENGINEERING, 2007, 35 (09) : 1608 - 1616
  • [6] A comparison of biomechanical properties between human and porcine cornea
    Zeng, YJ
    Yang, J
    Huang, K
    Lee, ZH
    Lee, XY
    JOURNAL OF BIOMECHANICS, 2001, 34 (04) : 533 - 537
  • [7] Characterising biomechanical properties of healthy human corneas with the Ocular Response Analyser and CorvisST
    Buckhurst, Hetal D.
    Purslow, Christine
    Buckhurst, Phillip J.
    Oehring, Daniela
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2018, 59 (09)
  • [8] Comparison of the Biomechanical Properties between Healthy and Whole Human and Porcine Stomachs
    Li, Feifei
    Liu, Jiannan
    Liu, Xiaoyun
    Wu, Yaobin
    Qian, Lei
    Huang, Wenhua
    Li, Yanbing
    BIOENGINEERING-BASEL, 2024, 11 (03):
  • [9] The biomechanical proteins different between low myopic corneas and moderate to high myopic corneas in human
    Wu, Wenjing
    Wang, Yan
    Chen, Jingyi
    Zhang, Fengju
    CONTACT LENS & ANTERIOR EYE, 2024, 47 (03):
  • [10] Glucose permeability of human, bovine, and porcine corneas in vitro
    Myung, David
    Derr, Kristen
    Huie, Philip
    Noolandi, Jaan
    Ta, Kathryn P.
    Ta, Christopher N.
    OPHTHALMIC RESEARCH, 2006, 38 (03) : 158 - 163