摘要
PURPOSE: To evaluate visual and perceptual performance for different orientations of a rotationally asymmetric bifocal intraocular lens (IOL) (M-Plus) simulated optically using a simultaneous vision simulator. SETTING: Institute de Optica, Madrid, Spain. DESIGN: Prospective observational study. METHODS: Perceptual quality and decimal high-contrast visual acuity (HCVA) was measured under cycloplegia for 8 orientations of the asymmetric bifocal IOL phase pattern at far, intermediate, and near distances simulated with a simultaneous vision simulator using face images and tumbling E targets. The preferred orientation at each distance was calculated as the centroid of the data for 8 orientations. The visual Strehl value was calculated using the subjects' ocular aberrations and multifocal pattern at each orientation. Optical predictions were obtained by implementing a differential visual Strehl values based ideal observer model. RESULTS: The study comprised 20 subjects (aged 21 to 62 years). Horizontal orientation (near segment at 0 or 180 degrees +/- 45 [SD]) was preferred by 14 subjects and by 13 subjects at far and near distances, respectively; 8 subjects showed strong orientation preferences. The mean difference in preferred orientation between far and near was 27 +/- 22 degrees. No significant differences in HCVA were observed. Optical predictions correlated strongly and significantly with measurements (far r = 0.71, near r = 0.62; P<.0001). The mean difference between measurement and simulation in the preferred orientation was 28 +/- 29 degrees at far and 36 +/- 28 degrees at near. CONCLUSIONS: The perception varied for different orientations of an asymmetric bifocal IOL design tested using a simultaneous vision simulator. Optimum orientation was driven by interactions of the design with the eye's optical aberrations.
引用
收藏
页码:1276 / 1287
页数:12
相关论文
共 50 条
  • [1] Comparative visual performance of diffractive bifocal and rotationally asymmetric refractive intraocular lenses
    Tanabe, Hirotaka
    Shojo, Tomohiro
    Yamauchi, Tomofusa
    Takase, Kosuke
    Akada, Masahiro
    Tabuchi, Hitoshi
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [2] Comparative visual performance of diffractive bifocal and rotationally asymmetric refractive intraocular lenses
    Hirotaka Tanabe
    Tomohiro Shojo
    Tomofusa Yamauchi
    Kosuke Takase
    Masahiro Akada
    Hitoshi Tabuchi
    Scientific Reports, 12
  • [3] Comparative Analysis of Visual Performance and Optical Quality with a Rotationally Asymmetric Multifocal Intraocular Lens and an Apodized Diffractive Multifocal Intraocular Lens
    Wang, Xiao
    Tu, Haixia
    Wang, Yong
    JOURNAL OF OPHTHALMOLOGY, 2020, 2020
  • [4] Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens
    Na Hui
    Mei-Fang Chu
    Yan Li
    Cong-Yi Wang
    Lei Yu
    Bo Ma
    International Journal of Ophthalmology, 2022, (09) : 1460 - 1467
  • [5] Comparative analysis of visual quality between unilateral implantation of a trifocal intraocular lens and a rotationally asymmetric refractive multifocal intraocular lens
    Hui, Na
    Chu, Mei-Fang
    Li, Yan
    Wang, Cong-Yi
    Yu, Lei
    Ma, Bo
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2022, 15 (09) : 1460 - 1467
  • [6] Rotationally asymmetric multifocal intraocular lens
    Carifi, Gianluca
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1116 - 1117
  • [7] Rotationally asymmetric multifocal intraocular lens Reply
    van der Linden, Jan Willem
    van Velthoven, Mirjam
    van der Meulen, Ivanka
    Nieuwendaal, Carla
    Mourits, Maarten
    Lapid-Gortzak, Ruth
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2012, 38 (06): : 1117 - 1117
  • [8] Visual Performance Following Bilateral Implantation of Refractive Rotationally Asymmetric Bifocal Intraocular Lens (LS-313 MF30) or Apodized Diffractive Bifocal Intraocular Lens (ReSTOR SN6AD1)
    Li, Honglei
    Liu, Dongle
    Gao, Han
    Sun, Jiajun
    Bai, Huiran
    Wu, Xiaoming
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2021, 17 : 917 - 926
  • [9] Quality of vision with the Acri.Twin asymmetric diffractive bifocal intraocular lens system
    Alfonso, Jose F.
    Fernandez-Vega, Luis
    Senaris, Ana
    Montes-Mico, Robert
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (02): : 197 - 202
  • [10] Design and fabrication of a microstructured bifocal intraocular lens
    Stork, W
    Wagner, A
    Kreiner, CF
    Müller-Glaser, KD
    OPHTHALMIC TECHNOLOGIES IX, PROCEEDINGS OF, 1999, 3591 : 259 - 266