Indoor CO2 Level-Based Occupancy Estimation at Low-Scale Occupant using Statistical Learning Method

被引:1
|
作者
Rahman, Haolia [1 ]
Abdillah, Abdul Azis [1 ]
Apriana, Asep [1 ]
Handaya, Devi [1 ]
Assagaf, Idrus [1 ]
机构
[1] Politekn Negeri Jakarta, Dept Mech Engn, Depok, Indonesia
关键词
occupancy estimation; carbon dioxide; statistical learning; low-scale occupants; ROOM;
D O I
10.1109/IC2IE53219.2021.9649072
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Most of the occupancy estimations based on indoor CO2 levels are tested on a large-scale number of occupants such the order of tens or hundreds. Logically because the pattern of the occupancy and CO2 level is about similar at a broad range of occupants. In the present study, a small office room with an occupancy scale of 0-6 people was tested. The Statistical Learning method is used to estimate the number of occupants, including Decision Tree, Random Forest classifier, SVM, Logistic regression, K-Nearest Neighbor, and Neural Network. A combination of training and testing data set is applied to the methods and a comparison has been made in order to distinguish their accuracy. The result shows that the accuracy of self-estimation and cross-estimation is ranged from 86-100% and 86-94% respectively. It also found that the estimation accuracy of self-and-cross validation does not significantly increase with the increase of data set combination.
引用
收藏
页码:496 / 499
页数:4
相关论文
共 50 条
  • [1] Estimation of indoor occupancy level based on machine learning and multimodal environmental data
    Siecinski, Szymon
    Mohammadi, Esfandiar
    Grzegorzek, Marcin
    2024 IEEE 22ND MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON 2024, 2024, : 868 - 872
  • [2] Low-cost data-driven estimation of indoor occupancy based on carbon dioxide (CO2) concentration: A multi-scenario case study
    Liang, Xiguan
    Shim, Jisoo
    Anderton, Owen
    Song, Doosam
    JOURNAL OF BUILDING ENGINEERING, 2024, 82
  • [3] Predictive control of indoor environment using occupant number detected by video data and CO2 concentration
    Wang, Fulin
    Feng, Qingqing
    Chen, Zheliang
    Zhao, Qianchuan
    Cheng, Zhijing
    Zou, Jianhong
    Zhang, Yufeng
    Mai, Jinbo
    Li, Yun
    Reeve, Hayden
    ENERGY AND BUILDINGS, 2017, 145 : 155 - 162
  • [4] Deep learning and computer vision based occupancy CO2 level prediction for demand-controlled ventilation (DCV)
    Wei, Shuangyu
    Tien, Paige Wenbin
    Chow, Tin Wai
    Wu, Yupeng
    Calautit, John Kaiser
    JOURNAL OF BUILDING ENGINEERING, 2022, 56
  • [5] Accurate occupancy detection of an office room from light, temperature, humidity and CO2 measurements using statistical learning models
    Candanedo, Luis M.
    Feldheim, Veronique
    ENERGY AND BUILDINGS, 2016, 112 : 28 - 39
  • [6] Effect of occupant-induced indoor CO2 concentration and bioeffluents on human physiology using a spirometric test
    Shriram, S.
    Ramamurthy, K.
    Ramakrishnan, S.
    BUILDING AND ENVIRONMENT, 2019, 149 : 58 - 67
  • [7] Estimation of time-varying air exchange rate using occupant-generated CO2
    Park, Sowoo
    Yan, Huijing
    Song, Doosam
    JOURNAL OF BUILDING ENGINEERING, 2025, 103
  • [8] Enhanced Building Thermal Model By using CO2 Based Occupancy Data
    Imanishi, Tomoya
    Tennekoon, Rajitha
    Palensky, Peter
    Nishi, Hiroaki
    IECON 2015 - 41ST ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2015, : 3116 - 3121
  • [9] STATISTICAL ESTIMATION OF VENTILATORY SENSITIVITY TO CO2 USING DIRECTIONAL DATA TECHNIQUES
    DAUBENSPECK, JA
    OGDEN, RD
    SINCLAIR, JD
    TENNEY, SM
    FEDERATION PROCEEDINGS, 1977, 36 (03) : 489 - 489
  • [10] Estimation of transport CO2 emissions using machine learning algorithm
    Li, Shengwei
    Tong, Zeping
    Haroon, Muhammad
    TRANSPORTATION RESEARCH PART D-TRANSPORT AND ENVIRONMENT, 2024, 133