Voltammetric behavior and analytical applications of lomefloxacin, an antibacterial fluorquinolone

被引:0
|
作者
Alvarez-Lueje, A [1 ]
López, C [1 ]
Núñez-Vergara, LJ [1 ]
Squella, JA [1 ]
机构
[1] Univ Chile, Chem & Pharmaceut Sci Fac, Bioelectrochem Lab, Santiago 1, Chile
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Lomefloxacin was reduced on a dropping mercury electrode, producing one or more peaks, depending on the pH of the aqueous medium. Coulometric measurements gave an experimental value of 1 electron for the main peak. Electrolysis was followed by UV spectrophotometry and liquid chromatography (LC), showing that a new band at 413 nm appeared for the electrolysis product in an acidic medium. Furthermore, by using UV spectrophotometry, an apparent pKa value of 6.75 +/- 0.05 was obtained for lomefloxacin corresponding to the carboxyl moiety in the 8-position. For analytical studies, the differential pulse polarographic mode in 0.1 N HCl was selected. The repeatability and reproducibility of the method were adequate (coefficient of variation [CV], 0.51 %), The calibration curve method was used for the lomefloxacin concentration range of 7.0 x 10(-6) to 7.0 x 10(-5)M. The detection and quantitation limits were 1.0 x 10(-6) and 6.9 x 10(-6)M, respectively. For purposes of comparison, both UV spectrophotometric and LC (with UV and fluorimetric detection) methods were developed. The polarographic method showed good selectivity with respect to both excipients and degradation products, The recovery study showed a CV of <2% and an average recovery of 99.5% and it was not necessary to treat the sample before analysis, The method was applied to the determination of the uniformity content of lomefloxacin commercial tablets, The polarographic method was also successfully applied to the quantitation of lomefloxacin in urine, and the renal excretion profile was also determined.
引用
收藏
页码:649 / 658
页数:10
相关论文
共 50 条
  • [1] VOLTAMMETRIC BEHAVIOR OF HYPONITRITE ION AND ITS ANALYTICAL APPLICATIONS
    CINQUANTINI, A
    RASPI, G
    ZANELLO, P
    ANALYTICA CHIMICA ACTA, 1976, 87 (01) : 51 - 57
  • [2] VOLTAMMETRIC BEHAVIOR OF COPPER(III) AND ITS ANALYTICAL APPLICATIONS
    RASPI, G
    ZANELLO, P
    CINQUANT.A
    CORTI, P
    ANALYTICA CHIMICA ACTA, 1973, 66 (03) : 435 - 442
  • [3] Differential-pulse adsorptive stripping voltammetric determination of the antibacterial lomefloxacin
    Vílchez, JL
    Araujo, L
    Prieto, A
    Navalón, A
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (01) : 23 - 29
  • [4] ANTIBACTERIAL ACTIVITY OF LOMEFLOXACIN
    LEIGH, DA
    TAIT, S
    WALSH, B
    JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1991, 27 (05) : 589 - 598
  • [5] ANTIBACTERIAL ACTIVITY OF LOMEFLOXACIN
    ROSS, PW
    REVIEWS OF INFECTIOUS DISEASES, 1989, 11 : S936 - S936
  • [6] Voltammetric Studies for Analytical Determination of Antibacterial Danofloxacin and Orbifloxacin
    Temerk, Yassien M.
    Kamal, Moustafa M.
    Ibrahim, Mohamed S.
    Alhagri, Ibrahim A.
    EURASIAN JOURNAL OF ANALYTICAL CHEMISTRY, 2009, 4 (01): : 53 - 65
  • [7] Voltammetric study of the interaction of lomefloxacin (LMF)-Mg(II) complex with DNA and its analytical application
    Zhang, N
    Zhang, XL
    Zhao, YF
    MICROCHEMICAL JOURNAL, 2003, 75 (03) : 249 - 254
  • [8] The polarographic and voltammetric behaviour of mitoxantrone and analytical applications
    Yang, P
    Wang, HF
    Zhou, GR
    Fan, HZ
    Pan, JH
    ANALYTICAL LETTERS, 1996, 29 (01) : 89 - 96
  • [9] Lomefloxacin hydrochloride Okacyn® -: Quinilone antibacterial
    不详
    DRUGS OF THE FUTURE, 2000, 25 (07) : 757 - 758
  • [10] ANALYTICAL UTILIZATION OF POLAROGRAPHIC AND VOLTAMMETRIC BEHAVIOR OF PURINES AND PYRIMIDINES
    SMITH, DL
    ELVING, PJ
    ANALYTICAL CHEMISTRY, 1962, 34 (08) : 930 - &