Determination of Size Distribution of Precipitation Aggregates Using Non-Invasive Microscopy and Semiautomated Image Processing and Analysis

被引:13
|
作者
Quilaqueo, Michelle [1 ]
Gim-Krumm, Minghai [1 ,2 ]
Ruby-Figueroa, Rene [3 ]
Troncoso, Elizabeth [2 ,3 ]
Estay, Humberto [1 ]
机构
[1] Univ Chile, AMTC, Av Tupper 2007,AMTC Bldg, Santiago 8370451, Chile
[2] Univ Tecnol Metropolitana, Dept Chem, Palmeras 3360, Santiago 7800003, Chile
[3] Univ Tecnol Metropolitana, Programa Inst Fomento Invest Desarrollo & Innovac, Ignacio Valdivieso 2409, Santiago 8940577, Chile
关键词
SART process; precipitation aggregates; image analysis; microscopy; particle size distribution; MICROSTRUCTURE; MORPHOLOGY;
D O I
10.3390/min9120724
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Particle size distribution (PSD) determination is a typical practice for the characterization of the slurries generated in a precipitation plant. Furthermore, the precipitates generated in these processes form colloidal or aggregated suspensions. Nevertheless, the conventional methods used to estimate PSD (e.g., laser diffraction and/or a cyclosizer) have not been designed to measure particles that tend to aggregate or disaggregate, since they include external forces (e.g., centrifugal, agitation, pumping and sonication). These forces affect the true size of the aggregates formed in a unit operation, thereby losing representativeness in terms of aggregates particle size. This study presents an alternative method of measuring the size distribution of particles with aggregation behavior, particularly, by using non-invasive microscopy and image processing and analysis. The samples used were obtained from an experimental precipitation process by applying sulfidization to treat the cyanide-copper complexes contained in a cyanidation solution. This method has been validated with statistical tools and compared with a conventional analysis based on laser diffraction (Mastersizer). The PSD results obtained with optical microscopy show a bi-modal behavior of the precipitates. However this behavior could be not determined when using the laser diffraction technique. The PSD obtained for the sample tested by microscopy had a mean of 119.7 mu m, a median of 147 mu m and a 90% distribution reached a particle size of 312.5 mu m. These values differ with those obtained by the laser diffraction technique. Our results show significant differences between the methods analyzed, demonstrating that the image processing and analysis obtained by optical microscopy is an excellent and non-invasive alternative to obtain size distributions of aggregates in precipitation processes.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Non-invasive estimation of the powder size distribution from a single speckle image
    Zhang, Qihang
    Pandit, Ajinkya
    Liu, Zhiguang
    Guo, Zhen
    Muddu, Shashank
    Wei, Yi
    Pereg, Deborah
    Nazemifard, Neda
    Papageorgiou, Charles
    Yang, Yihui
    Tang, Wenlong
    Braatz, Richard D.
    Myerson, Allan S.
    Barbastathis, George
    LIGHT-SCIENCE & APPLICATIONS, 2024, 13 (01)
  • [2] Automated confocal laser scanning microscopy and semiautomated image processing for analysis of biofilms
    Kuehn, M
    Hausner, M
    Bungartz, HJ
    Wagner, M
    Wilderer, PA
    Wuertz, S
    APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1998, 64 (11) : 4115 - 4127
  • [3] Non-invasive image acquisition and advanced processing in optical bioimaging
    Farkas, Daniel L.
    Du, Congwu
    Fisher, Gregory W.
    Lau, Christopher
    Niu, Wenhua
    Wachman, Elliot S.
    Levenson, Richard M.
    Computerized Medical Imaging and Graphics, 22 (02): : 89 - 102
  • [4] Automated Diagnosis of Diabetic Retinopathy using image processing for non-invasive biomedical application
    Gautam, Aishwarya Singh
    Jana, Saikat Kumar
    Dutta, Manash Pratim
    PROCEEDINGS OF THE 2019 INTERNATIONAL CONFERENCE ON INTELLIGENT COMPUTING AND CONTROL SYSTEMS (ICCS), 2019, : 809 - 812
  • [5] Non-invasive Image Processing Method for Detecting Seed Vigor
    Li, Mingjian
    Guo, Jiahan
    Yu, Zheng
    Yan, Lei
    Han, Ning
    ADVANCED DESIGN AND MANUFACTURING TECHNOLOGY III, PTS 1-4, 2013, 397-400 : 2134 - 2137
  • [6] Fast and Non-invasive Surface Crack Detection of Press Panels Using Image Processing
    Jung, HweeKwon
    Lee, ChangWon
    Park, Gyuhae
    STRUCTURAL HEALTH MONITORING - FROM SENSING TO DIAGNOSIS AND PROGNOSIS, 2017, 188 : 72 - 79
  • [7] Non-invasive image acquisition and advanced processing in optical bioimaging
    Farkas, DL
    Du, CW
    Fisher, GW
    Lau, C
    Niu, WH
    Wachman, ES
    Levenson, RM
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1998, 22 (02) : 89 - 102
  • [8] Cutaneous endometriosis: non-invasive analysis by epiluminescence microscopy
    De Giorgi, V
    Massi, D
    Mannone, F
    Stante, M
    Carli, P
    CLINICAL AND EXPERIMENTAL DERMATOLOGY, 2003, 28 (03) : 315 - 317
  • [9] Corneal Confocal Microscopy: A Rapid Non-Invasive Technique to Image Neurodegeneration
    Malik, Rayaz
    Petropoulos, Ioannis
    MULTIPLE SCLEROSIS JOURNAL, 2019, 25 : 18 - 19
  • [10] Determination of Ligament Size Distribution of Nanoporous Gold by Scanning Electron Microscopy and Image Analysis
    Li, Zhengmin
    Zhou, Shuping
    Li, Hongtao
    Si, Weijiang
    Ding, Yi
    JOURNAL OF NANOSCIENCE AND NANOTECHNOLOGY, 2009, 9 (02) : 1651 - 1654