An improved ion chromatography method for determination of trace level perchlorate in environmental water

被引:0
|
作者
Mang Ping [1 ]
Shi Ya-Li [1 ]
Cai Ya-Qi [1 ]
Mou Shi-Fen [1 ]
机构
[1] Chinese Acad Sci, State Key Lab Environm Chem & Ecotox, Res Ctr Ecoenvironm Sci, Beijing 100085, Peoples R China
来源
关键词
perchlorate; ion chromatography; environmental water sample;
D O I
暂无
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
An improved ion chromatography( IC) method was developed to determine trace level perchlorate in environmental water samples by using hydroxide selective column lonPac AS16. Perchorate was separated with NaOH eluent added organic modifier. To eliminate the coelution of perchlorate and 4-chlorobenzene sulfonate(4-CBS), organic solvents as the modifier was added into the eluent. The effects of four kinds of organic solvents on the retention time of perchlorate and 4-CBS were studied, and acetonitrile was selected. To improve the method sensitivity, the concentrator column(AG19) was used to concentrate perchlorate online in this work. With the adoption of. preconcentration technique, the sensitivity of this method was improved obviously and the method detection limit ( MDL) is 0.1 mu g/L. The linear range is 0.2-200 mu g/L with a linear correlation coefficient of 0.9989, and the relative standard deviation( RSD) of peak area for the eleven successive injections of 0.5 mu g/L perchlorate is 4.2%. The method was applied to the determination of perchlorate in some real environmental water samples and the spiked recoveries were in the range of 93 % - 113%.
引用
收藏
页码:1246 / 1250
页数:5
相关论文
共 17 条
  • [1] [Anonymous], US EPA PUBL
  • [2] Rapid on-line preconcentration and suppressed micro-bore ion chromatography of part per trillion levels of perchlorate in rainwater samples
    Barron, Leon
    Nesterenko, Pavel N.
    Paull, Brett
    [J]. ANALYTICA CHIMICA ACTA, 2006, 567 (01) : 127 - 134
  • [3] Burns DT, 1997, ANAL CHIM ACTA, V356, P141
  • [4] Optimization of operating conditions for the determination of perchlorate in biological samples using preconcentration/preelution ion chromatography
    Cañas, JE
    Cheng, QQ
    Tian, K
    Anderson, TA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2006, 1103 (01) : 102 - 109
  • [5] Improved method for the determination of trace perchlorate in ground and drinking waters by ion chromatography
    Jackson, PE
    Gokhale, S
    Streib, T
    Rohrer, JS
    Pohl, CA
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2000, 888 (1-2) : 151 - 158
  • [6] Perchlorate and iodide in dairy and breast milk
    Kirk, AB
    Martinelango, PK
    Tian, K
    Dutta, A
    Smith, EE
    Dasgupta, PK
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2005, 39 (07) : 2011 - 2017
  • [7] Analysis of perchlorate in groundwater by electrospray ionization mass spectrometry/mass spectrometry
    Koester, CJ
    Beller, HR
    Halden, RU
    [J]. ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2000, 34 (09) : 1862 - 1864
  • [8] Determination of perchlorate at trace levels in drinking water by ion-pair extraction with electrospray ionization mass spectrometry
    Magnuson, ML
    Urbansky, ET
    Kelty, CA
    [J]. ANALYTICAL CHEMISTRY, 2000, 72 (01) : 25 - 29
  • [9] PERCIASEPE R, 1998, FED REGISTER, V63, P10274
  • [10] Construction and evaluation of ion selective electrodes for perchlorate with a summing operational amplifier:: application to pyrotechnics mixtures analysis
    Pérez-Olmos, R
    Rios, A
    Martín, MP
    Lapa, RAS
    Lima, JLFC
    [J]. ANALYST, 1999, 124 (01) : 97 - 100