Generation of planar images from lung ventilation/perfusion SPECT

被引:20
|
作者
Bailey, Dale L. [1 ,2 ,3 ,4 ]
Schembri, Geoffrey P. [1 ,2 ]
Harris, Benjamin E. [2 ,5 ,6 ]
Bailey, Elizabeth A. [1 ]
Cooper, Robert A. [1 ]
Roach, Paul J. [1 ,2 ]
机构
[1] Royal N Shore Hosp, Dept Nucl Med, St Leonards, NSW 2065, Australia
[2] Univ Sydney, No Clin Sch, Fac Med, Sydney, NSW 2006, Australia
[3] Univ Sydney, Sch Phys, Sydney, NSW 2006, Australia
[4] Univ Sydney, Sch Med Radiat Sci, Sydney, NSW 2006, Australia
[5] Royal N Shore Hosp, Dept Resp Med, Sydney, NSW, Australia
[6] Univ Sydney, Woolcock Inst Med Res, Sydney, NSW 2006, Australia
关键词
SPECT (single photon emission computed tomography); lung; pulmonary embolus; gamma camera;
D O I
10.1007/s12149-007-0120-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objective To develop a method of producing lung ventilation and perfusion (V/Q) planar images using forward projection of reconstructed single-photon emission computed tomography (SPECT) images through approximate attenuation (mu) maps generated from the lung emission scans alone, as transmission-based mu maps may not be routinely available. Methods Synthetic mu maps are derived from Tc-99m photopeak and "scatter" windows for the attenuation correction of the SPECT images. The attenuation-corrected SPECT images are forward projected at appropriate angles to give the equivalent of planar images. This method allows high-count planar images, as well as the SPECT images, to be produced from a single SPECT acquisition. In addition, isolated "single lung" views of lateral and medial projections without "shine-through" from the contra-lateral lung, which have not been available previously, can be formed. Results Comparison of reprojected images produced from CT-derived or synthetic mu maps displayed similar detail and radiopharmaceutical distribution. In a blinded comparison of "true" planar images with those from reprojecting the SPECT data using the synthetic mu maps, no difference in mismatched defect detection was found, and hence it was confirmed that the reprojected planar images could replace true planar images with no loss in planar diagnostic sensitivity. Conclusions The reprojected planar images provide high-count, high-quality images, which are comparable with conventional 2D images.
引用
收藏
页码:437 / 445
页数:9
相关论文
共 50 条
  • [1] Generation of planar images from lung ventilation/perfusion SPECT
    Dale L. Bailey
    Geoffrey P. Schembri
    Benjamin E. Harris
    Elizabeth A. Bailey
    Robert A. Cooper
    Paul J. Roach
    Annals of Nuclear Medicine, 2008, 22
  • [2] Ventilation/Perfusion Scintigraphy of the Lung-Planar or SPECT?
    Smid, G.
    Poharc, B.
    Kac, M.
    Kovacic, M.
    Hudournik, M.
    Kuder, E.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 : S295 - S295
  • [3] A COMPARISON OF SPECT AND PLANAR VENTILATION PERFUSION LUNG-SCANNING
    EUSTACE, S
    PHELAN, N
    DOWSETT, DJ
    ENNIS, JT
    IRISH JOURNAL OF MEDICAL SCIENCE, 1993, 162 (03) : 82 - 85
  • [4] Spurious lung perfusion ventilation defect on planar ventilation- perfusion scan detected by SPECT imaging
    Farahmandfar, Fatemeh
    Shakeri, Sara
    Masoudi, Toktam
    Moghadam, Soroush Zarehparvar
    Sadeghi, Ramin
    IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2020, 28 (02): : 30 - 33
  • [5] Histogram matching for the generation of ventilation-perfusion difference images in SPECT lung scanning: A phantom study
    Smith, Jye
    Bartlett, Marissa
    Thomas, Paul
    MEDICAL PHYSICS, 2012, 39 (06) : 3026 - 3030
  • [6] Ventilation perfusion functional difference images in lung SPECT: A linear and symmetrical scale as an alternative to the ventilation perfusion ratio
    de Nijs, Robin
    Berg, Ronan M. G.
    Hansen, Sofie Lindskov
    Mortensen, Jann
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 119
  • [7] SPECT/CT imaging of lung perfusion in the diagnosis of pulmonary embolism: Comparison with planar ventilation-perfusion lung scintigraphy
    Revel, C.
    Poisson, T.
    Revel, A.
    Daragon, N.
    Grandpierre, S.
    Netter, F.
    Scigliano, S.
    Djaballah, W.
    Olivier, P.
    Karcher, G.
    Marie, P. -Y.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (06): : 313 - 322
  • [8] Ventilation/perfusion SPECT in patients with nondiagnostic planar lung scintigraphy and suspicion of pulmonary embolism
    Weinmann, P
    Tofighi, M
    Rebillard, O
    Obenga, G
    Moretti, JL
    Brauner, MW
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2004, 31 : S254 - S254
  • [9] Reinventing ventilation/perfusion lung scanning with SPECT
    Roach, Paul J.
    Bailey, Dale L.
    Schembri, Geoffrey P.
    NUCLEAR MEDICINE COMMUNICATIONS, 2008, 29 (12) : 1023 - 1025
  • [10] Validity of angular sum as planar extraction technique of lung ventilation-perfusion SPECT data
    Cambefort, R.
    Le Duc-Pennec, A.
    Guillo, P.
    Le Gal, G.
    Querellou, S.
    Abgral, R.
    Leroyer, C.
    Mottier, D.
    Salauen, P.-Y.
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2009, 33 (09): : 533 - 538