Optimizing signal-to-noise ratio of high-resolution parallel single-shot diffusion-weighted echo-planar imaging at ultrahigh field strengths

被引:8
|
作者
Reischauer, Carolin [1 ]
Vorburger, Robert S. [1 ]
Wilm, Bertram J. [1 ]
Jaermann, Thomas [1 ,2 ]
Boesiger, Peter [1 ]
机构
[1] Univ & ETH Zurich, Inst Biomed Engn, CH-8092 Zurich, Switzerland
[2] ZHAW Zurich Univ Appl Sci, Sch Engn, Zurich, Switzerland
关键词
high-resolution diffusion-weighted imaging; echo-planar imaging; signal-to-noise ratio; parallel imaging; ultrahigh field strengths; HUMAN BRAIN; ELECTROMAGNETIC-FIELDS; RELAXATION-TIMES; FIBER TRACKING; IN-VIVO; SENSE; SENSITIVITY; NMR; MRI; TRANSMIT;
D O I
10.1002/mrm.23057
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The potential signal-to-noise ratio (SNR) gain at ultrahigh field strengths offers the promise of higher image resolution in single-shot diffusion-weighted echo-planar imaging the challenge being reduced T2 and T2* relaxation times and increased B0 inhomogeneity which lead to geometric distortions and image blurring. These can be addressed using parallel imaging (PI) methods for which a greater range of feasible reduction factors has been predicted at ultrahigh field strengthsthe tradeoff being an associated SNR loss. Using comprehensive simulations, the SNR of high-resolution diffusion-weighted echo-planar imaging in combination with spin-echo and stimulated-echo acquisition is explored at 7 T and compared to 3 T. To this end, PI performance is simulated for coil arrays with a variable number of circular coil elements. Beyond that, simulations of the point spread function are performed to investigate the actual image resolution. When higher PI reduction factors are applied at 7 T to address increased image distortions, high-resolution imaging benefits SNR-wise only at relatively low PI reduction factors. On the contrary, it features generally higher image resolutions than at 3 T due to smaller point spread functions. The SNR simulations are confirmed by phantom experiments. Finally, high-resolution in vivo images of a healthy volunteer are presented which demonstrate the feasibility of higher PI reduction factors at 7 T in practice. Magn Reson Med, 2012. (c) 2011 Wiley Periodicals, Inc.
引用
收藏
页码:679 / 690
页数:12
相关论文
共 50 条
  • [1] Diffusion-weighted single-shot echo-planar imaging with parallel technique in assessment of endometrial cancer
    Shen, Shu-Huei
    Chiou, Yi-You
    Wang, Jia-Hwia
    Yen, Ming-Shyen
    Lee, Rheun-Chuan
    Lai, Chiung-Ru
    Chang, Cheng-Yen
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 190 (02) : 481 - 488
  • [2] High-resolution diffusion-weighted imaging at 7 Tesla: Single-shot readout trajectories and their impact on signal-to-noise ratio, spatial resolution and accuracy
    Feizollah, Sajjad
    Tardif, Christine L.
    NEUROIMAGE, 2023, 274
  • [3] Single-Shot Multiecho Parallel Echo-Planar Imaging (EPI) for Diffusion Tensor Imaging (DTI) With Improved Signal-to-Noise Ratio (SNR) and Reduced Distortion
    Nana, Roger
    Zhao, Tiejun
    Hu, Xiaoping
    MAGNETIC RESONANCE IN MEDICINE, 2008, 60 (06) : 1512 - 1517
  • [4] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Hong, Ben-Zu
    Li, Xin-Feng
    Lin, Jian-Qing
    WORLD JOURNAL OF GASTROENTEROLOGY, 2015, 21 (20) : 6374 - 6380
  • [5] Differential diagnosis of pancreatic cancer by single-shot echo-planar imaging diffusion-weighted imaging
    Ben-Zu Hong
    Xin-Feng Li
    Jian-Qing Lin
    World Journal of Gastroenterology, 2015, (20) : 6374 - 6380
  • [6] Robust Fat Suppression at 3T in High-Resolution Diffusion-Weighted Single-Shot Echo-Planar Imaging of Human Brain
    Sarlls, Joelle E.
    Pierpaoli, Carlo
    Talagala, S. Lalith
    Luh, Wen-Ming
    MAGNETIC RESONANCE IN MEDICINE, 2011, 66 (06) : 1658 - 1665
  • [7] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Wu, Chen-Jiang
    Wang, Qing
    Zhang, Jing
    Wang, Xiao-Ning
    Liu, Xi-Sheng
    Zhang, Yu-Dong
    Shi, Hai-Bin
    ABDOMINAL RADIOLOGY, 2016, 41 (01) : 100 - 108
  • [8] Readout-segmented echo-planar imaging in diffusion-weighted imaging of the kidney: comparison with single-shot echo-planar imaging in image quality
    Chen-Jiang Wu
    Qing Wang
    Jing Zhang
    Xiao-Ning Wang
    Xi-Sheng Liu
    Yu-Dong Zhang
    Hai-Bin Shi
    Abdominal Radiology, 2016, 41 : 100 - 108
  • [9] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [10] Comparison of multiplexed sensitivity encoding and single-shot echo-planar imaging for diffusion-weighted imaging of the liver
    Kim, Yeun-Yoon
    Kim, Myeong-Jin
    Gho, Sung-Min
    Seo, Nieun
    EUROPEAN JOURNAL OF RADIOLOGY, 2020, 132