Ethanol Biomarker Testing and Challenges Lessons Learned From a College of American Pathologists Proficiency Testing Survey

被引:2
|
作者
Snozek, Christine L. H. [1 ]
Souers, Rhona [2 ]
Dizon, Annabel [3 ]
Magnani, Barbarajean [4 ]
Krasowski, Matthew D. [5 ]
机构
[1] Mayo Clin Arizona, Dept Lab Med & Pathol, 13400 E Shea Blvd, Scottsdale, AZ 85259 USA
[2] Coll Amer Pathologists, Biostat Div, Northfield, IL USA
[3] Coll Amer Pathologists, Proficiency Testing Div, Northfield, IL USA
[4] Tufts Med Ctr, Dept Pathol & Lab Med, Boston, MA 02111 USA
[5] Univ Iowa Hosp & Clin, Dept Pathol, Iowa City, IA 52242 USA
关键词
ETHYL GLUCURONIDE; DRINKING; SULFATE; PROPYL;
D O I
10.5858/arpa.2020-0699-CP
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
Context.-Clinical and forensic testing for ethanol biomarkers, including ethyl glucuronide (EtG) and ethyl sulfate (EtS), is used to discern alcohol use from abstinence. These markers can be key in major decisions, including transplant eligibility or retaining licensure after alcohol misuse. Accuracy, precision, and recognition of the implications of reporting cutoffs are all essential for correct interpretation. Objective.-To evaluate trends in testing for EtG and EtS, including how laboratories perform testing and how comparable participant results are. Design.-The study examined the College of American Pathologists ethanol biomarker proficiency testing survey from 2013 to 2019. Trends in methodology, reporting cutoffs, and participant performance were evaluated for qualitative and quantitative EtG testing and for quantitative EtS testing. Results.-There was little consensus in reporting cutoffs, which ranged from 10 to 1000 ng/mL for EtG and 10 to 1500 ng/mL for EtS. Although median EtG and EtS compared well with target concentrations, individual participants' results varied widely. For quantitative enzyme immunoassay, accuracy and precision were best in EtG challenges less than 1500 ng/mL. For EtG or EtS by mass spectrometry, overall accuracy was good over a wide concentration range, but variability between participants was high. Approximately 10% (409 of 4059) of results were unacceptable, which for mass spectrometry corresponded to more than 35% above or below the group mean. Conclusions.-Although many participants performed well, there was insufficient consensus in reporting cutoffs, and a consistent fraction of laboratories failed to achieve survey standards. Guidelines for assay performance and reporting could greatly benefit laboratories and end users. (Arch Pathol Lab Med. 2021;145:1492-1498 ; doi: 10.5858/arpa.2020-0699-CP)
引用
收藏
页码:1492 / 1498
页数:7
相关论文
共 50 条
  • [1] Performance of Herpes Simplex Challenges in Proficiency Testing Observations From the College of American Pathologists Proficiency Testing Program
    Moriarty, Ann T.
    Darragh, Teresa M.
    Souers, Rhona
    Fatheree, Lisa A.
    Wilbur, David C.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2009, 133 (09) : 1379 - 1382
  • [2] The parentage testing proficiency survey program of the college of American pathologists
    Harrison, CR
    Endean, D
    Morris, J
    Polesky, H
    Roby, R
    Walker, R
    ADVANCES IN FORENSIC HAEMOGENETICS, 6, 1996, 6 : 682 - 682
  • [3] SUMMARY OF 1972 MYCOLOGY PROFICIENCY TESTING SURVEY OF COLLEGE-OF-AMERICAN-PATHOLOGISTS
    DOLAN, CT
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1974, 61 (06) : 990 - 993
  • [4] Performance of Herpes Simplex Challenges in Proficiency Testing: Observations from the College of American Pathologists (CAP) Proficiency Testing (PAP PT) Program
    Moriarty, Ann T.
    Darragh, Teresa M.
    Souers, Rhona
    Fatheree, Lisa A.
    Wilbur, David C.
    CANCER CYTOPATHOLOGY, 2008, 114 (05) : 394 - 394
  • [5] Antinuclear Antibodies Testing Method Variability: A Survey of Participants in the College of American Pathologists' Proficiency Testing Program
    Naides, Stanley J.
    Genzen, Jonathan R.
    Abel, Gyorgy
    Bashleben, Christine
    Ansari, M. Qasim
    JOURNAL OF RHEUMATOLOGY, 2020, 47 (12) : 1768 - 1773
  • [6] Automatic Failure in Gynecologic Cytology Proficiency Testing Results From the College of American Pathologists Proficiency Testing Program
    Moriarty, Ann T.
    Crothers, Barbara A.
    Bentz, Joel S.
    Souers, Rhona J.
    Fatheree, Lisa A.
    Wilbur, David C.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2009, 133 (11) : 1757 - 1760
  • [7] SURVEY OF SPECIAL PRACTICES ASSOCIATED WITH COLLEGE OF AMERICAN PATHOLOGISTS PROFICIENCY TESTING IN THE COMMONWEALTH OF PENNSYLVANIA
    CEMBROWSKI, GS
    VANDERLINDE, RE
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 1988, 112 (04) : 374 - 376
  • [8] Variability in the Laboratory Measurement of Cytokines A Longitudinal Summary of a College of American Pathologists Proficiency Testing Survey
    Knight, Vijaya
    Long, Thomas
    Meng, Qing H.
    Linden, Michael A.
    Rhoads, Daniel D.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2020, 144 (10) : 1230 - 1233
  • [9] Performance of Candida-Fungal-Induced Atypia and Proficiency Testing Observations From the College of American Pathologists Proficiency Testing Program
    Moriarty, Ann T.
    Darragh, Teresa M.
    Fatheree, Lisa A.
    Souers, Rhona
    Wilbur, David C.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2009, 133 (08) : 1272 - 1275
  • [10] Quality assurance in hemostasis: The perspective from the College of American Pathologists proficiency testing program
    Cunningham, Mark T.
    Brandt, John T.
    Chandler, Wayne L.
    Eby, Charles S.
    Hayes, Timothy E.
    Krishnan, Jayashree
    Lefkowitz, Jerry B.
    Olson, John D.
    Stasik, Christopher J.
    Teruya, Jun
    Van Cott, Elizabeth M.
    SEMINARS IN THROMBOSIS AND HEMOSTASIS, 2007, 33 (03): : 250 - 258