Study on the mechanical behavior of a foundation pit retaining structure adjacent to the pile foundation of a subway station

被引:11
|
作者
Zhang, Qian [1 ]
Hu, Jie [2 ]
Wang, Jing [3 ]
He, Peng [4 ]
Hou, Lili [1 ]
Lin, Peng [3 ]
Song, Shuguang [5 ]
机构
[1] Shijiazhuang Tiedao Univ, Shijiazhuang 050043, Hebei, Peoples R China
[2] Nanjing Univ Sci & Technol, Sch Mech Engn, Nanjing 210094, Peoples R China
[3] Shandong Univ, Geotech & Struct Engn Res Ctr, Jinan 250061, Shandong, Peoples R China
[4] China Railway First Grp Co Ltd, Xian 710000, Shanxi, Peoples R China
[5] Shandong Jianzhu Univ, Jinan 250003, Shandong, Peoples R China
基金
国家重点研发计划; 中国博士后科学基金;
关键词
Subway; Foundation pit engineering; Limited soil; Earth pressure; Laboratory model test; EARTH PRESSURE; PERFORMANCE; SETTLEMENT; WALL;
D O I
10.1007/s12665-021-09996-7
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The numerous effects of adjacent structures should be considered in the design and construction of subway stations. The subway station expansion project confined to a small space in Shenzhen City was taken as engineering background to study the earth pressure distribution in a limited space. Both theoretical analysis and laboratory model testing methods were used to study the mechanical behavior of the subway station retaining structure adjacent to a pile foundation. The main conclusions are as follows: (1) When the soil around the foundation pit is non-cohesive, the soil pressure is smaller than that calculated by classical soil pressure theory, and the difference between the two increases with an increase in the angle of internal friction. If the lateral inclination continues to increase, then the pressure will approach the value determined by classical theory. (2) The soil pressure distribution and variation rule are greatly influenced by factors such as the length-diameter ratio, excavation depth, internal friction angle and friction between the soil and retaining structure. The dip angle of the sliding surface of the finite soil increases with decreasing friction angle and is inversely correlated with the aspect ratio. The active soil pressure is inversely proportional to the internal friction angle of the soil and positively correlated with height. When the internal friction angle is constant and the length-diameter ratio is equal to the critical length-diameter ratio, the active earth pressure coefficient is equal to the Coulomb active earth pressure coefficient and reaches its maximum value. (3) The deformation of the foundation pit retaining structure has an important influence on the distribution of soil pressure around it. These results offer a reference for the engineering design and construction of supporting structures for deep foundation pits adjacent to existing adjacent structures.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Study on the mechanical behavior of a foundation pit retaining structure adjacent to the pile foundation of a subway station
    Qian Zhang
    Jie Hu
    Jing Wang
    Peng He
    Lili Hou
    Peng Lin
    Shuguang Song
    Environmental Earth Sciences, 2021, 80
  • [2] Monitoring and numerical simulation of deformation of retaining structure in subway station foundation pit
    Liu Jie
    Yao Hai-lin
    Ren Jian-xi
    ROCK AND SOIL MECHANICS, 2010, 31 : 456 - 461
  • [3] Deformation Monitoring and Numerical Simulation of Retaining Structure in Subway Station Deep Foundation Pit
    Li Jin-Wei
    Li Xuan
    Xiong Meng-Xin
    Luo Hao-Fang
    ELECTRONIC JOURNAL OF GEOTECHNICAL ENGINEERING, 2016, 21 (06): : 2331 - 2340
  • [4] Field Experimental Study on Mechanical Properties of Frame Support Structure Composed of Subway Foundation Pit Retaining Pile and Steel Strut Rigid Joint
    Huang, Mingli
    Zhien, Zhang
    Chen, Bingyi
    Wang, Hongkun
    ADVANCES IN CIVIL ENGINEERING, 2022, 2022
  • [5] Deformation Effects of Deep Foundation Pit Excavation on Retaining Structures and Adjacent Subway Stations
    Jiang, Zhijian
    Zhu, Shu
    Que, Xiangcheng
    Ge, Xinliang
    BUILDINGS, 2024, 14 (08)
  • [6] Deformation analysis of adjacent subway station by different parameters of composite support structure in deep foundation pit
    Peng, Hua
    Proceedings of SPIE - The International Society for Optical Engineering, 2021, 12058
  • [7] Foundation pit stability analysis for mixing-pile retaining structure
    Tu, Yumin
    Wei, Rulong
    Gongye Jianzhu/Industrial Construction, 28 (05): : 5 - 8
  • [8] Study on the influence of deep foundation pit excavation on the deformation of adjacent viaduct pile foundation
    Wang, Haitao
    Xu, Mingyang
    Guo, Tao
    Cui, Minghua
    Tian, Jiangtao
    INTERNATIONAL JOURNAL OF CRITICAL INFRASTRUCTURES, 2024, 20 (03) : 288 - 307
  • [9] Numerical Study on the Deformation of Tunnels by Excavation of Foundation Pit Adjacent to the Subway
    Zhao, Xiang
    Wang, Hanxuan
    Li, Zhongwei
    Dai, Guoliang
    Yin, Ziwei
    Cao, Shuning
    Zhou, Junlong
    APPLIED SCIENCES-BASEL, 2022, 12 (09):
  • [10] Analysis of Surveillance for Deep Foundation Pit of Subway Station
    Duan, Baofu
    Li, Lei