Parametric blind deconvolution of microscopic images: Further results

被引:8
|
作者
Markham, J [1 ]
Conchello, JA [1 ]
机构
[1] Washington Univ, Inst Biomed Comp, St Louis, MO 63110 USA
关键词
blind deconvolution; 3D microscopy; maximum likelihood;
D O I
10.1117/12.310535
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Blind deconvolution microscopy, the simultaneous estimation of the specimen function and the point spread function (PSF) of the microscope is an under-determined problem with non-unique solutions. The non-uniqueness is commonly avoided by enforcing constraints on both the specimen function and the PSF, such as non-negativity and band limitation. These constraints are some times enforced in ad hoc ways. In addition, many of the existing methods for blind deconvolution estimate the PSF pixel by pixel thus greatly increasing the number of parameters to estimate and slowing the convergence of the algorithm. We derived a maximum-likelihood-based method for blind deconvolution in which we assume that the PSF follows a mathematical expression that depends on a small number of parameters (e.,g. less than 20). The algorithm then estimates the unknown parameters together with the specimen function. The mathematical model ensures that all the constraints of the PSF are satisfied and the maximum likelihood approach ensures that the specimen is non-negative. This parametric blind deconvolution method successfully removes out-of-focus blur but its degree of success depends on the features of the specimen. Specimen features that fall in mostly the null space of the PSF are more difficult to recover and make PSF estimation more difficult.
引用
收藏
页码:38 / 49
页数:12
相关论文
共 50 条
  • [1] Parametric blind deconvolution of fluorescence microscopy images: Preliminary results
    Conchello, JA
    Yu, QR
    THREE-DIMENSIONAL MICROSCOPY: IMAGE ACQUISITION AND PROCESSING III, 1996, 2655 : 164 - 174
  • [2] Parametric blind deconvolution for passive millimeter wave images with framelet regularization
    Fang, Houzhang
    Yan, Luxin
    OPTIK, 2014, 125 (03): : 1454 - 1460
  • [3] Phase and TV Based Convex Sets for Blind Deconvolution of Microscopic Images
    Tofighi, Mohammad
    Yorulmaz, Onur
    Koese, Kivanc
    Yildirim, Deniz Cansen
    Cetin-Atalay, Rengul
    Cetin, A. Enis
    IEEE JOURNAL OF SELECTED TOPICS IN SIGNAL PROCESSING, 2016, 10 (01) : 81 - 91
  • [4] Blind deconvolution of medical ultrasound images: A parametric inverse filtering approach
    Michailovich, Oleg
    Tannenbaum, Allen
    IEEE TRANSACTIONS ON IMAGE PROCESSING, 2007, 16 (12) : 3005 - 3019
  • [6] Parametric blind deconvolution for passive millimeter wave images basing on image decomposition
    Fang, Houzhang
    Yan, Luxin
    Zhang, Tianxu
    Liu, Hai
    Jin, Mingzhi
    MIPPR 2011: MULTISPECTRAL IMAGE ACQUISITION, PROCESSING, AND ANALYSIS, 2011, 8002
  • [7] Initialization of iterative parametric algorithms for blind deconvolution of motion-blurred images
    Loyev, V
    Yitzhaky, Y
    APPLIED OPTICS, 2006, 45 (11) : 2444 - 2452
  • [8] Blind Deconvolution of SEM Images
    Vanderlinde, William E.
    Caron, James N.
    ISTFA 2007, 2007, : 97 - +
  • [9] BLIND DECONVOLUTION OF SPECKLE IMAGES
    LANE, RG
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1992, 9 (09): : 1508 - 1514
  • [10] Blind deconvolution of blurred images
    Walsh, TD
    Vincent, R
    ELECTRON MICROSCOPY AND ANALYSIS 1997, 1997, (153): : 191 - 194