Self-navigated multishot echo-planar pulse sequence for high-resolution diffusion-weighted imaging

被引:32
|
作者
Nunes, RG [1 ]
Jezzard, P [1 ]
Behrens, TEJ [1 ]
Clare, S [1 ]
机构
[1] Univ Oxford, John Radcliffe Hosp, FMRIB Ctr, Dept Clin Neurol, Oxford OX3 9DU, England
关键词
diffusion-weighted imaging; high resolution; motion correction; navigator; keyhole; DTI;
D O I
10.1002/mrm.20499
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Single-shot techniques have preferentially been adopted for diffusion-weighted imaging due to their reduced sensitivity to bulk motion. However, the limited spatial resolution achievable results in orientational signal averaging within voxels containing a distribution of fibers. This leads to impaired performance of tracking algorithms. To combat partial volume effects, high-resolution multishot techniques can be used but, being more sensitive to motion, require phase correction to obtain artifact-free images. While separately acquiring 2D navigator echoes is an effective approach, it is not very efficient as the navigators do not contribute signal to the final image. Here a self-navigated interleaved echo planar imaging (EPI) sequence based on EPI with keyhole (EPIK) is proposed. The refocusing reconstruction method is successfully adapted to EPIK and compared to the standard linear approach. The resultant improvement in resolution is shown to lead to a significant increase in anisotropy in fiber-branching areas and can potentially offer a superior ability to detect fine tract splits. (c) 2005 Wiley-Liss, Inc.
引用
收藏
页码:1474 / 1478
页数:5
相关论文
共 50 条
  • [1] Water/fat separation for self-navigated diffusion-weighted multishot echo-planar imaging
    Dong, Yiming
    Riedel, Malte
    Koolstra, Kirsten
    van Osch, Matthias J. P.
    Bornert, Peter
    NMR IN BIOMEDICINE, 2023, 36 (01)
  • [2] Diffusion-weighted imaging with navigated interleaved echo-planar imaging and a conventional gradient system
    Bammer, P
    Stollberger, R
    Augustin, M
    Simbrunner, J
    Offenbacher, H
    Kooijman, H
    Ropele, S
    Kapeller, P
    Wach, P
    Ebner, F
    Fazekas, F
    RADIOLOGY, 1999, 211 (03) : 799 - 806
  • [3] Detection of Middle Ear Cholesteatoma by Diffusion-Weighted MR Imaging: Multishot Echo-Planar Imaging Compared with Single-Shot Echo-Planar Imaging
    Yamashita, K.
    Yoshiura, T.
    Hiwatashi, A.
    Kamano, H.
    Dashjamts, T.
    Shibata, S.
    Tamae, A.
    Honda, H.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (10) : 1915 - 1918
  • [4] Hepatic metastases: use of diffusion-weighted echo-planar imaging
    Bruegel, Melanie
    Rummeny, Ernst J.
    ABDOMINAL IMAGING, 2010, 35 (04): : 454 - 461
  • [5] Gradient preemphasis calibration in diffusion-weighted echo-planar imaging
    Papadakis, NG
    Martin, KM
    Pickard, JD
    Hall, LD
    Carpenter, TA
    Huang, CLH
    MAGNETIC RESONANCE IN MEDICINE, 2000, 44 (04) : 616 - 624
  • [6] Hepatic metastases: use of diffusion-weighted echo-planar imaging
    Melanie Bruegel
    Ernst J. Rummeny
    Abdominal Imaging, 2010, 35 : 454 - 461
  • [7] Gradient preemphasis calibration in diffusion-weighted echo-planar imaging
    Papadakis, Nikolaos G.
    Martin, Kay M.
    Pickard, John D.
    Hall, Laurance D.
    Carpenter, T. Adrian
    Huang, Christopher L.-H.
    2000, John Wiley and Sons Inc. (44)
  • [8] Increased-contrast, high-spatial-resolution, diffusion-weighted, spin-echo, echo-planar imaging
    Thompson, MR
    Venkatesan, R
    Kuppusamy, K
    Celik, A
    Lin, WL
    Kido, DK
    Haacke, EM
    RADIOLOGY, 1999, 210 (01) : 253 - 259
  • [9] Accelerated Acquisition of High-resolution Diffusion-weighted Imaging of the Brain with a Multi-shot Echo-planar Sequence: Deep-learning-based Denoising
    Kawamura, Motohide
    Tamada, Daiki
    Funayama, Satoshi
    Kromrey, Marie-Luise
    Ichikawa, Shintaro
    Onishi, Hiroshi
    Motosugi, Utaroh
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2021, 20 (01) : 99 - 105
  • [10] Imaging the microcirculatory proton fraction of muscle with diffusion-weighted echo-planar imaging
    Yao, L
    Sinha, U
    ACADEMIC RADIOLOGY, 2000, 7 (01) : 27 - 32