摘要
The calibration process for flow conductometric sensors of electrical conductivity and their concentration in solutions of NaOH, NaCl, and Na2CO3 are studied. Two-electrode sensors in glass tubes were used with platinum electrodes combined with the developed resistometer. The measuring system resistometer-sensor KSN-19, KSN-22, and KSN-23 operates on a pulsed alternating current at a frequency of 4 kHz. The calibration dependences of the concentration-resistance sensors in the above solutions were measured. Three main parameters of the sensors were determined by means of special software processing of the calibration data and their comparison with precise reference functions, namely, the "sensor constant" K-S, K-S1, and K-S3. It is shown that all characteristic parameters of the sensors depend on the chemical composition of the analyzed medium, and they are not constants. Theoretical substantiations of the observed regularity are given.
引用
收藏
页码:540 / 547
页数:8
相关论文
共 50 条
  • [1] Determining Conditional Constants of Conductometric Sensors
    N. D. Koshel’
    S. A. Koshel’
    Surface Engineering and Applied Electrochemistry, 2022, 58 : 540 - 547
  • [2] SOME OBSERVATIONS ON CONDUCTOMETRIC METHOD FOR DETERMINING SOLVOLYTIC RATE CONSTANTS
    MCDONALD, RN
    DAVIS, GE
    JOURNAL OF ORGANIC CHEMISTRY, 1973, 38 (01): : 138 - 144
  • [3] ELECTRICALLY FOCUSED CONDUCTOMETRIC SENSORS
    PLOSHINSKII, AV
    MEASUREMENT TECHNIQUES USSR, 1988, 31 (10): : 1015 - 1018
  • [4] Investigation of conductometric humidity sensors
    Barkauskas, J
    TALANTA, 1997, 44 (06) : 1107 - 1112
  • [5] Determining conditional stability constants for Pb complexation by carboxyrnethyl-β-cyclodextrin (CMCD)
    Skold, Magnus E.
    Thyne, Geoffrey D.
    Drexler, John W.
    McCray, John E.
    JOURNAL OF CONTAMINANT HYDROLOGY, 2007, 93 (1-4) : 203 - 215
  • [6] Development of an Electronic Nose for Determining the Freshness of Fish by the Desorption Constants of Sensors
    Vorobioff, J.
    Rodriguez, D. F.
    Boggio, N. G.
    Rinaldi, C. A.
    SENSOR LETTERS, 2013, 11 (12) : 2215 - 2217
  • [7] Oxide nanobelts as conductometric gas sensors
    Comini, E
    Faglia, G
    Sberveglieri, G
    Zanotti, L
    MATERIALS AND MANUFACTURING PROCESSES, 2006, 21 (03) : 229 - 232
  • [8] CONDUCTOMETRIC APPARATUS FOR DETERMINING PHOTOSYNTHESIC RATE
    VOZNESENSKII, VL
    BIOLOGIA PLANTARUM, 1964, 6 (02) : 79 - &
  • [9] AN IMPROVEMENT IN CONDUCTOMETRIC METHOD FOR DETERMINING NITROGEN IN STEEL
    GLUSHKO, YV
    SHMELEV, BA
    INDUSTRIAL LABORATORY, 1966, 32 (01): : 12 - &
  • [10] CONDUCTOMETRIC METHOD FOR DETERMINING THE CONDUCTIVITY OF POLYELECTROLYTE SOLUTIONS
    Kokoeva, A. A.
    Begieva, M. B.
    Malkanduev, Yu A.
    Dokshukina, M. A.
    PHYSICAL AND CHEMICAL ASPECTS OF THE STUDY OF CLUSTERS NANOSTRUCTURES AND NANOMATERIALS, 2019, (11) : 177 - 183