An experimental study on performance during reverse cycle defrosting of an air source heat pump with a horizontal three circuit outdoor coil

被引:11
|
作者
Song Mengjie [1 ]
Xu Xiangguo [2 ]
Deng Shiming [1 ]
Mao Ning [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong, Hong Kong, Peoples R China
[2] Zhejiang Univ, Inst Refrigerat & Cryogen, Hangzhou 310003, Zhejiang, Peoples R China
关键词
Air source heat pump; Defrosting; Melted frost; Experiment; Multi-circuit Horizontal;
D O I
10.1016/j.egypro.2014.11.914
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
When the surface temperature of the outdoor coil in an air source heat pump (ASHP) unit is below both the air dew point and freezing point of water, frost can be formed and accumulated over the surface of the outdoor coil, which is usually of multi-circuit structure in order to minimize its refrigerant pressure loss and enhance the heat transfer between refrigerant and ambient air. However, frosting adversely affects the operational performance and hence the energy efficiency of the ASHP unit, therefore periodic defrosting is necessary. Currently, the most widely standard defrosting method used for ASHP units is reverse cycle defrosting. A previous related study has suggested that during reverse cycle defrosting, downwards flowing of melted frost due to gravity over a vertical multi-circuit outdoor coil in an ASHP unit could deteriorate defrosting performance, by using more energy for defrosting and prolonging a defrosting process. If however an outdoor coil can be horizontally installed, the flow path for melted frost over coil surface can be shortened, and a better defrosting performance expected. In this paper, therefore, an experimental study on performance during reverse cycle defrosting of an ASHP unit having a horizontal three-circuit outdoor coil has been carried out. Firstly, a detailed description of the ASHP unit is presented. This is followed by reporting the experimental results. Finally, a comparative and quantitative analysis is given.
引用
收藏
页码:92 / 95
页数:4
相关论文
共 50 条
  • [1] A modeling study on alleviating uneven defrosting for a vertical three-circuit outdoor coil in an air source heat pump unit during reverse cycle defrosting
    Song Mengjie
    Xia Liang
    Deng Shiming
    APPLIED ENERGY, 2016, 161 : 268 - 278
  • [2] Experimental investigation on an air source heat pump unit with a three-circuit outdoor coil for its reverse cycle defrosting termination temperature
    Song Mengjie
    Gong Guangcai
    Mao Ning
    Deng Shiming
    Wang Zhihua
    APPLIED ENERGY, 2017, 204 : 1388 - 1398
  • [3] An experimental study on the effects of downwards flowing of melted frost over a vertical multi-circuit outdoor coil in an air source heat pump on defrosting performance during reverse cycle defrosting
    Song, Mengjie
    Deng, Shiming
    Pan, Dongmei
    Mao, Ning
    APPLIED THERMAL ENGINEERING, 2014, 67 (1-2) : 258 - 265
  • [4] A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - Part I: Experiments
    Qu Minglu
    Xia Liang
    Deng Shiming
    Jiang Yiqiang
    APPLIED ENERGY, 2012, 91 (01) : 122 - 129
  • [5] A study of the reverse cycle defrosting performance on a multi-circuit outdoor coil unit in an air source heat pump - Part II: Modeling analysis
    Qu, Minglu
    Pan, Dongmei
    Xia, Liang
    Deng, Shiming
    Jiang, Yiqiang
    APPLIED ENERGY, 2012, 91 (01) : 274 - 280
  • [6] An experimental study on defrosting performance for an air source heat pump unit with a horizontally installed multi-circuit outdoor coil
    Song Mengjie
    Deng Shiming
    Mao Ning
    Ye Xianming
    APPLIED ENERGY, 2016, 165 : 371 - 382
  • [7] An experimental study on the negative effects of downwards flow of the melted frost over a multi-circuit outdoor coil in an air source heat pump during reverse cycle defrosting
    Song Mengjie
    Pan Dongmei
    Li Ning
    Deng Shiming
    APPLIED ENERGY, 2015, 138 : 598 - 604
  • [8] An experimental study on the uneven refrigerant distribution over a vertically installed multi-circuit outdoor coil in an air source heat pump unit during reverse cycle defrosting
    Song, Mengjie
    Wang, Zhihua
    Mao, Ning
    Li, Zhao
    Chen, Ying
    APPLIED THERMAL ENGINEERING, 2015, 91 : 975 - 985
  • [9] Performance of an air-source heat pump with multi-circuit outdoor coil for continuous heating during defrosting
    Tang, Lan
    Liu, Xi 'an
    He, Shiquan
    Li, Qingjian
    JOURNAL OF BUILDING ENGINEERING, 2024, 85
  • [10] An experimental study on defrosting performance of an air source heat pump unit with a multi-circuit outdoor coil at different frosting evenness values
    Song, Mengjie
    Chen, Ailu
    Mao, Ning
    APPLIED THERMAL ENGINEERING, 2016, 94 : 331 - 340