Comparison of List-Mode and DIRECT Approaches for Time-of-Flight PET Reconstruction

被引:0
|
作者
Daube-Witherspoon, Margaret E. [1 ]
Matej, Samuel [2 ]
Werner, Matthew E. [2 ]
Surti, Suleman [2 ]
Karp, Joel S. [2 ]
机构
[1] Univ Penn, Dept Radiol, 11316 Smoke Rise Court, Fairfax Stn, VA 22039 USA
[2] Univ Penn, Dept Radiol, Philadelphia, PA 19104 USA
来源
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC) | 2010年
关键词
Time-of-flight PET; PET reconstruction; EMISSION-TOMOGRAPHY-SYSTEMS; IMAGE-RECONSTRUCTION; IMPACT;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Early clinical results with time-of-flight (TOF) PET systems have demonstrated the advantages of TOF information in PET reconstruction. Reconstruction approaches in TOF-PET systems include list-mode and binned iterative algorithms as well as confidence-weighted analytic methods. List-mode iterative TOF reconstruction retains the full accuracy of the data in the spatial and temporal domains but is computationally intensive. We have developed an approach [DIRECT (direct image reconstruction for TOF)] to speed up TOF reconstruction that takes advantage of the reduced angular sampling requirement of TOF data by grouping list-mode data into a small number of azimuthal views and co-polar tilts and depositing the grouped events into histo-images, arrays with the sampling and geometry of the final image. All physical effects are included in the system model and deposited in the same histo-image structure. Using histo-images allows efficient computation during reconstruction without ray-tracing or interpolation operations. The DIRECT approach was compared with the 3D list-mode TOF ordered subsets expectation maximization (OSEM) reconstruction for phantom and patient data taken on the UPenn prototype LaBr3 TOF-PET scanner. The total reconstruction time with DIRECT for data with 430-ps timing resolution was 1/3 that of list-mode TOF-OSEM to achieve comparable image quality. While the reconstruction time for list-mode TOF-OSEM depends on the number of events and sizes of the spatial and TOF kernels, the time for DIRECT is independent of these factors. The DIRECT approach is able to reproduce the image quality of the list-mode iterative TOF reconstruction both qualitatively and quantitatively in measured data with a significantly reduced time.
引用
收藏
页码:2252 / 2258
页数:7
相关论文
共 50 条
  • [1] Comparison of List-Mode and DIRECT Approaches for Time-of-Flight PET Reconstruction
    Daube-Witherspoon, Margaret E.
    Matej, Samuel
    Werner, Matthew E.
    Surti, Suleman
    Karp, Joel S.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (07) : 1461 - 1471
  • [2] Analytic reconstruction methods for list-mode time-of-flight PET
    Kao, Chien-Min
    Guo, Jinxia
    Kim, Heejong
    Xie, Qingguo
    Chen, Chin-Tu
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3492 - 3494
  • [3] PyTomography: Advancements in List-mode and Time-of-Flight PET Image Reconstruction
    Polson, Luke
    Karakatsanis, Nicolas
    Uribe, Carlos
    Rahmim, Arman
    JOURNAL OF NUCLEAR MEDICINE, 2024, 65
  • [4] Fast List-Mode Reconstruction for Time-of-Flight PET Using Graphics Hardware
    Pratx, Guillem
    Surti, Suleman
    Levin, Craig
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2011, 58 (01) : 105 - 109
  • [5] List-mode quantitative joint reconstruction of activity and attenuation maps in Time-of-Flight PET
    Hemmati, Hamidreza
    Kamali-Asl, Alireza
    Ghafarian, Pardis
    Rahmim, Arman
    Zaidi, Habib
    Ay, Mohammad Reza
    JOURNAL OF INSTRUMENTATION, 2023, 18 (09)
  • [6] 3D PET list-mode iterative reconstruction using time-of-flight information
    Groiselle, CJ
    Glick, SJ
    2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, : 2633 - 2638
  • [7] GPU-accelerated list-mode reconstruction for 3-D time-of-flight (TOF) PET
    Pratx, Guillem
    Surti, Suleman
    Levin, Craig
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [8] Systematic and Distributed Time-of-Flight List Mode PET Reconstruction
    Wang, W.
    Hu, Z.
    Gualtieri, E. E.
    Parma, M. J.
    Walsh, E. S.
    Sebok, D.
    Hsieh, Y. -L.
    Tung, C. -H.
    Song, X.
    Griesmer, J. J.
    Kolthammer, J. A.
    Popescu, L. M.
    Werner, M.
    Karp, J. S.
    Gagnon, D.
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 1715 - 1722
  • [9] Fully 3D list-mode time-of-flight PET image reconstruction on GPUs using CUDA
    Cui, Jing-yu
    Pratx, Guillem
    Prevrhal, Sven
    Levin, Craig S.
    MEDICAL PHYSICS, 2011, 38 (12) : 6775 - 6786
  • [10] Incorporation of Time-of-Flight information in PET List-Mode reconstruction using a projector with accurate detector PSF modeling
    Autret, Awen
    Bert, Julien
    Strauss, Olivier
    Visvikis, Dimitris
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,