Thermal Performance Test on Nuclear Power Station: A Case Study in Taiwan

被引:0
|
作者
Chan, Yea-Kuang [1 ]
机构
[1] Inst Nucl Energy Res, Nucl Engn Div, 1000 Wenhua Rd, Taoyuan 32546, Taiwan
关键词
Thermal performance test; measurement uncertainty analysis; turbine generator; MEASUREMENT UNCERTAINTY;
D O I
10.1080/00295450.2017.1338879
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
The baseline and verification performance tests based on American Society of Mechanical Engineers (ASME) Performance Test Code 6 (PTC 6) for Maanshan Nuclear Power Station (MNPS) Unit 1 were successfully conducted prior to and after the replacement of a high-pressure turbine rotor. In order to verify that the actual improvement in electrical output resulting from this replacement meets the vendor's guarantee, measurement uncertainty analysis of the thermal performance test was calculated. Two verification performance tests show that the deviation for the corrected heat rates of the two tests differs by only 0.11%, which therefore meets the ASME PTC 6 requirements where the deviation between two tests should be within 0.25%. Thus, the quality of the test results is acceptable. After accounting for the test uncertainty, the test results demonstrated that the improvement in gross electrical output compared to the baseline performance test is between 12.57 and 22.63 MW(electric), which is higher than the contract guarantee of 10.0 MW(electric). Moreover, the major parameters of the turbine cycle measured during verification performance tests have established a reference base for monitoring the plant operating performance and provide useful information to turbine cycle design for a nuclear power plant.
引用
收藏
页码:80 / 92
页数:13
相关论文
共 50 条
  • [1] PERFORMANCE OF NUCLEAR POWER STATION PLANT
    EVANS, DT
    JONES, FRR
    PRIOR, WJ
    JOURNAL OF THE BRITISH NUCLEAR ENERGY SOCIETY, 1965, 4 (03): : 217 - &
  • [2] Trustworthiness test of nuclear power station employees
    Gegusch, M
    PHYSICAL PROTECTION OF NUCLEAR MATERIALS: EXPERIENCE IN REGULATION, IMPLEMENTATION AND OPERATIONS, 1998, : 305 - 309
  • [3] Analysis of ferroresonant overvoltages at Maanshan Nuclear Power Station in Taiwan
    Tsao, TP
    Nine, CC
    IEEE TRANSACTIONS ON POWER DELIVERY, 2006, 21 (02) : 1006 - 1012
  • [4] Full Performance Study on Mass Concrete of X Nuclear Power Station
    Zhang, Bao-Liang
    Yi, Xiu-Jun
    MANUFACTURING CONSTRUCTION AND ENERGY ENGINEERING: 2016 INTERNATIONAL CONFERENCE ON MANUFACTURING CONSTRUCTION AND ENERGY ENGINEERING, 2016, : 497 - 503
  • [5] OPTIMIZING CAPACITY OF NUCLEAR POWER PLANTS - THERMAL PERFORMANCE ASSESSMENT USING A CASE STUDY
    Raj, Komandur Sunder
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 1, 2012, : 91 - 99
  • [6] DEVELOPING A THERMAL PERFORMANCE MONITORING SYSTEM SPECIFICATION FOR A NUCLEAR POWER PLANT - A CASE STUDY
    Raj, Komandur Sunder
    PROCEEDINGS OF THE 20TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING AND THE ASME 2012 POWER CONFERENCE - 2012, VOL 1, 2012, : 101 - 105
  • [7] Economic and financial benefits as a compensation for living near a nuclear power station a case study of Kashiwazaki-Kariwa Nuclear Power Station
    Graduate School of Environmental Engineering, University of Kitakyushu, 1-1 Hibikino, Wakamatsu-ku, Kitakyushu 808-0135, Japan
    不详
    不详
    不详
    Trans. At. Energy Soc. Jpn., 2007, 4 (404-420):
  • [8] DETERMINATION OF THERMAL EFFICIENCY OF A NUCLEAR-POWER STATION
    ROGENER, H
    KLOBASA, F
    BRENNSTOFF-WARME-KRAFT, 1977, 29 (12): : 469 - 471
  • [9] SUPERPOWER TURBOGENERATORS FOR NUCLEAR AND THERMAL POWER-STATION
    GLEBOV, IA
    VESTNIK AKADEMII NAUK SSSR, 1978, (04) : 13 - 30
  • [10] A Case Study of ESP Electrical Characteristics from a Thermal Power Station
    Popa, Gabriel Nicolae
    Abrudean, Cristian
    Deaconu, Sorin Ioan
    Popa, Iosif
    Vaida, Victor