Water Exchange (WE) and Quality Improvement-Enhanced Advanced Adenoma Detection A Pooled Data Analysis of 6 Randomized Controlled Trials

被引:11
|
作者
Leung, Felix W. [1 ,2 ]
Koo, Malcolm [5 ,9 ]
Jia, Hui [1 ,2 ,10 ]
Leung, Joseph W. [3 ,4 ]
Cadoni, Sergio [11 ]
Falt, Premysl [13 ,14 ,15 ]
Hsieh, Yu-Hsi [7 ,8 ]
Hu, Chi-Tan [6 ,7 ]
Pan, Yanglin [10 ]
Radaelli, Franco [12 ]
机构
[1] VAGLAHS, Sepulveda Ambulatory Care Ctr, Dept Med, Div Gastroenterol, Los Angeles, CA USA
[2] Univ Calif Los Angeles, David Geffen Sch Med, Los Angeles, CA 90095 USA
[3] UC Davis Med Ctr, Dept Gastroenterol, Sacramento, CA USA
[4] Sacramento VAMC Vet Affairs Northern Calif Health, Dept Gastroenterol, Mather, CA USA
[5] Tzu Chi Univ Sci & Technol, Grad Inst Long Term Care, Hualien, Taiwan
[6] Hualien Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Hualien, Taiwan
[7] Tzu Chi Univ, Dept Med, Hualien, Taiwan
[8] Dalin Tzu Chi Hosp, Buddhist Tzu Chi Med Fdn, Chiayi, Taiwan
[9] Univ Toronto, Dalla Lana Sch Publ Hlth, Toronto, ON, Canada
[10] Fourth Mil Med Univ, Xijing Hosp Digest Dis, Xian, Shaanxi, Peoples R China
[11] St Barbara Hosp, Digest Endoscopy Unit, Iglesias, CI, Italy
[12] Valduce Hosp, Div Digest Endoscopy & Gastroenterol, Como, Italy
[13] Univ Hosp, Olomouc, Czech Republic
[14] Fac Med, Olomouc, Czech Republic
[15] Charles Univ Prague, Fac Med, Hradec Kralove, Czech Republic
关键词
overall adenoma detection rate; advanced adenoma detection rate; air insufflation; water exchange; FORWARD-VIEWING COLONOSCOPY; SOCIETY-TASK-FORCE; COLORECTAL-CANCER; SCREENING COLONOSCOPY; ASSISTED COLONOSCOPY; CONSENSUS UPDATE; AIR INSUFFLATION; SURVEILLANCE; MULTICENTER; ENDOSCOPY;
D O I
10.1097/MCG.0000000000001311
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Introduction: Advanced adenomas (>= 10 mm in diameter, >25% villous, or high-grade dysplasia), a marker of colorectal cancer risk, are used to stratify patients for closer surveillance. Modern accessories, endoscopes, and age-adjusted evaluation have variable impacts on the advanced adenoma detection rate (AADR). In 1 randomized controlled trial (RCT) comparing air insufflation (AI) with water exchange (WE), the right colon AADR was significantly increased by WE. Four network meta-analyses reported that WE significantly increased overall adenoma detection rate (ADR), but the impact on AADR was not addressed. Aim: The aim of this study was to test the hypothesis that WE significantly increased AADR compared with AI. Method: Six Clinicaltrial.gov-registered RCTs were reported by a group of WE investigators. Data including AADR (primary outcome) and overall ADR (secondary outcome) were pooled. Results: A total of 5407 patients were randomized to AI (2699) and WE (2708). Compared with AI, WE significantly increased AADR (5.7% vs. 8.3%, P=0.001) and overall ADR (20.9% vs. 27.4%, P=0.001). Conclusions: In contrast to published reports, which showed variable impacts on AADR, WE was consistent in increasing AADR in 6 reported RCTs. The pooled data confirm that the impact of WE in increasing AADR was significant. The significantly enhanced overall ADR indicated that WE provided a higher quality outcome than AI. The significant improvement in AADR confirmed WE to be clinically relevant and has finally arrived as a timely addition to colorectal cancer prevention programs.
引用
收藏
页码:212 / 217
页数:6
相关论文
共 50 条
  • [1] Adenoma and Advanced Adenoma Detection Rates of Water Exchange, Endocuff, and Cap Colonoscopy: A Network Meta-Analysis with Pooled Data of Randomized Controlled Trials
    Shao, Paul P.
    Bui, Aileen
    Romero, Tahmineh
    Jia, Hui
    Leung, Felix W.
    DIGESTIVE DISEASES AND SCIENCES, 2021, 66 (04) : 1175 - 1188
  • [2] ADENOMA AND ADVANCED ADENOMA DETECTION RATE OF WATER EXCHANGE, ENDOCUFF AND CAP COLONOSCOPY - A NETWORK META-ANALYSIS WITH POOLED DATA OF RANDOMIZED CONTROLLED TRIALS
    Shao, Paul
    Romero, Tamineh
    Jia, Hui
    Bui, Aileen
    Leung, Felix W.
    GASTROENTEROLOGY, 2020, 158 (06) : S912 - S912
  • [3] Adenoma and Advanced Adenoma Detection Rates of Water Exchange, Endocuff, and Cap Colonoscopy: A Network Meta-Analysis with Pooled Data of Randomized Controlled Trials
    Paul P. Shao
    Aileen Bui
    Tahmineh Romero
    Hui Jia
    Felix W. Leung
    Digestive Diseases and Sciences, 2021, 66 : 1175 - 1188
  • [4] WATER EXCHANGE AND COMPUTER-AIDED DETECTION IMPROVED ADENOMA DETECTION RATE - A META-ANALYSIS OF POOLED DATA FROM RANDOMIZED CONTROLLED TRIALS
    Shao, Paul
    Kuo, Jonathan
    Romero, Tahmineh
    Leung, Felix
    GASTROINTESTINAL ENDOSCOPY, 2024, 99 (06) : AB536 - AB537
  • [5] Comparing Advanced Adenoma Detection Rate Between Water Exchange and Computer-Aided Colonoscopy Using Pooled Data From Randomized Controlled Trials
    Shao, Paul P.
    Kuo, Jonathan
    Shao, Changhan R.
    Leung, Felix W.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2023, 118 (10): : S187 - S188
  • [6] Comparing Advanced Adenoma Detection Rate of Water Exchange, Cap, and Endocuff Colonoscopy: Pooled Data of Randomized Controlled Trials With Air Insufflation as the Common Comparator
    Shao, Paul
    Bui, Aileen
    Jia, Hui
    Leung, Felix
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2019, 114 : S318 - S318
  • [7] Water Exchange Produces Significantly Higher Adenoma Detection Rate Than Water Immersion Pooled Data From 2 Multisite Randomized Controlled Trials
    Leung, Felix W.
    Koo, Malcolm
    Cadoni, Sergio
    Falt, Premysl
    Hsieh, Yu-Hsi
    Amato, Arnaldo
    Erriu, Matteo
    Fojtik, Petr
    Gallittu, Paolo
    Hu, Chi-Tan
    Leung, Joseph W.
    Liggi, Mauro
    Paggi, Silvia
    Radaelli, Franco
    Rondonotti, Emanuele
    Smajstrla, Vit
    Tseng, Chih-Wei
    Urban, Ondrej
    JOURNAL OF CLINICAL GASTROENTEROLOGY, 2019, 53 (03) : 204 - 209
  • [8] Comparing Sessile Serrated Adenoma/Polyp Detection Rate Between Water Exchange and Computer-Aided Detection Colonoscopy Using Pooled Data From Randomized Controlled Trials
    Shao, Paul P.
    Kuo, Jonathan
    Shao, Changhan R.
    Leung, Felix W.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2023, 118 (10): : S286 - S287
  • [9] Reproducibility of Water Exchange (WE) Method on Enhanced Adenoma Detection
    Leung, Felix W.
    Jia, Hui
    Pan, Yanglin
    Guo, Xuegang
    Wu, Kaichun
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB147 - AB148
  • [10] WATER EXCHANGE (WE) SIGNIFICANTLY RAISES ADENOMA DETECTION RATE (ADR) COMPARED WITH WATER IMMERSION (WI) AND AIR INSUFFLATION (AI) - POOLED DATA FROM TWO MULTI-SITE RANDOMIZED CONTROLLED TRIALS (RCT)
    Leung, Felix W.
    Koo, Malcolm
    Cadoni, Sergio
    Falt, Premysl
    Hsieh, Yu-Hsi
    Amato, Arnaldo
    Erriu, Matteo
    Fojtik, Petr
    Gallittu, Paolo
    Hu, Chi-Tan
    Leung, Joseph W.
    Liggi, Mauro
    Paggi, Silvia
    Radaelli, Franco
    Rondonotti, Emanuele
    Smajstrla, Vit
    Tseng, Chih Wei
    Urban, Ondrej
    GASTROENTEROLOGY, 2017, 152 (05) : S643 - S644