Determination of electroosmotic flow in nonaqueous capillary electrophoresis

被引:33
|
作者
Geiser, L [1 ]
Mirgaldi, M [1 ]
Veuthey, JL [1 ]
机构
[1] Univ Geneva, Sch Pharm, Lab Pharmaceut Analyt Chem, CH-1211 Geneva, Switzerland
关键词
nonaqueous capillary electrophoresis; hydroorganic solvent; electroosmotic flow; dielectric constant; viscosity; donor number;
D O I
10.1016/j.chroma.2005.02.001
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Mobility of the electroosmotic flow (mu(EOF)) in fused-silica capillaries strongly depends on the nature of the background electrolyte. In this study, 27 solvent systems were investigated, namely water, methanol, ethanol, 2-propanol, 1-butanol, acetonitrile (MeCN), formamide, N-methylformamide (NMF), N,N-dimethylformamide and dimethyl sulfoxyde, as well as 8 hydroorganic and 9 organic mixtures. For each system, six mu(EOF) were determined at a different ionic strength in basic conditions, and an absolute electroosmotic flow mobility (mu(EOF,0)) was extrapolated according to the Debye-Huckel Onsager model. The obtained mu(EOR,0) values were correlated with the solvent's relative permittivity (epsilon) and viscosity (eta). A good correlation (r(2) = 0.867) between mu(EOF,0) and the solvent's epsilon/eta ratio was demonstrated, except for two solvents (MeCN and NMF). Furthermore, the donor number (DN) of a solvent took into account the possible zeta potential modification in the electric double layer near the capillary wall. Consequently, the relationship between mu(EOF,0) and epsilon/(eta x DN) was superior, with a r(2) of 0.943 for 10 pure solvents. (c) 2005 Elsevier B.V. All rights reserved.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [1] Control of electroosmotic flow in nonaqueous capillary electrophoresis by polymer capillary coatings
    Steiner, F
    Hassel, M
    ELECTROPHORESIS, 2003, 24 (03) : 399 - 407
  • [2] Characteristics of the electroosmotic flow of electrolyte systems for nonaqueous capillary electrophoresis
    Grob, M
    Steiner, F
    ELECTROPHORESIS, 2002, 23 (12) : 1853 - 1861
  • [3] Evaluation of electroosmotic markers in aqueous and nonaqueous capillary electrophoresis
    Hellqvist, Alexander
    Hedeland, Ylva
    Pettersson, Curt
    ELECTROPHORESIS, 2013, 34 (24) : 3252 - 3259
  • [4] MANIPULATION OF ELECTROOSMOTIC FLOW IN CAPILLARY ELECTROPHORESIS
    YAO, XW
    WU, D
    REGNIER, FE
    JOURNAL OF CHROMATOGRAPHY, 1993, 636 (01): : 21 - 29
  • [5] CONTROLLING ELECTROOSMOTIC FLOW IN CAPILLARY ZONE ELECTROPHORESIS
    COHEN, N
    GRUSHKA, E
    JOURNAL OF CHROMATOGRAPHY A, 1994, 678 (01) : 167 - 175
  • [6] Measurement of electroosmotic flow in capillary and microchip electrophoresis
    Wang, Wei
    Zhou, Fang
    Zhao, Liang
    Zhang, Jian-Rong
    Zhu, Jun-Jie
    JOURNAL OF CHROMATOGRAPHY A, 2007, 1170 (1-2) : 1 - 8
  • [7] Characterization of electroosmotic flow in argentation capillary electrophoresis
    Fu, CG
    Wang, LX
    Liu, DJ
    CHROMATOGRAPHIA, 2000, 51 (9-10) : 591 - 594
  • [8] Characterization of electroosmotic flow in argentation capillary electrophoresis
    C. G. Fu
    L. X. Wang
    D. J. Liu
    Chromatographia, 2000, 51 : 591 - 594
  • [9] Dynamic capillary coatings for electroosmotic flow control in capillary electrophoresis
    Melanson, JE
    Baryla, NE
    Lucy, CA
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2001, 20 (6-7) : 365 - 374
  • [10] Manipulation of electroosmotic flow in capillary electrophoresis for iodide and iodate
    Ren, HX
    Wu, MJ
    CHEMICAL JOURNAL OF CHINESE UNIVERSITIES-CHINESE, 1997, 18 (04): : 541 - 543