Relaxation Response of Lumbar Segments Undergoing Disc-Space Distraction Implications to the Stability of Anterior Lumbar Interbody Implants

被引:4
|
作者
Havey, Robert M. [2 ]
Voronov, Leonard I. [2 ]
Tsitsopoulos, Parmenion P. [2 ]
Carandang, Gerard [2 ]
Ghanayem, Alexander J. [2 ]
Lorenz, Mark A. [2 ]
Zindrick, Michael R. [2 ]
Patwardhan, Avinash G. [1 ,2 ]
机构
[1] Loyola Univ, Med Ctr, Dept Orthopaed Surg & Rehabil, Maywood, IL 60153 USA
[2] Edward Hines Jr VA Hosp, Dept Vet Affairs, Musculoskeletal Biomech Lab, Hines, IL USA
关键词
lumbar spine; anterior interbody implants; annular pretension; disc-space distraction; stabilization; distraction force; compressive preload; ANULUS FIBROSUS; POSTERIOR INSTRUMENTATION; INTERVERTEBRAL DISKS; TENSILE PROPERTIES; FUSION CAGES; SPINE; BEHAVIOR; DEGENERATION; STRATEGIES; LIGAMENTS;
D O I
10.1097/BRS.0b013e3182323adc
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A biomechanical study of human cadaveric lumbar spine segments undergoing disc-space distraction for insertion of anterior lumbar interbody implants. Objective. To measure the distraction force and its relaxation during a period of up to 3 hours after disc-space distraction as a function of the distraction magnitude and disc level. Summary of Background Data. Interbody implants depend on compressive preload produced by disc-space distraction (annular pretension) for initial stabilization of the implant-bone interface. However, the amount of preload produced by disc-space distraction due to insertion of the implant and its subsequent relaxation have not been quantified. Methods. Twenty-two fresh human lumbar motion segments (age: 51 +/- 14.8 years) were used. An anterior lumbar discectomy was performed. The distraction test battery consisted of a tension stiffness test performed before and after each relaxation test, 2 distraction magnitudes of 2 and 4 mm, and a recovery period before each distraction input. The distraction forces and lordosis angles were measured. Results. Peak distraction force was significantly larger for the 4-mm distraction (431.8 +/- 116.4 N) than for the 2-mm distraction (204.9 +/- 55.5 N) (P < 0.01). The distraction force significantly decreased over time (P < 0.01), approximating steady-state values of 146.1 +/- 47.3 N at 2-mm distraction and 289.8 +/- 92.8 N at 4-mm distraction, respectively. The distraction force reduced in magnitude by more than 20% of peak value in the first 15 minutes and reduced by approximately 30% of the peak value at the end of the testing period. The spine segment relaxed by the same amount of force, regardless of the disc level (P > 0.05). Conclusion. The "tightness of fit" that the surgeon notes immediately after interbody device insertion in the disc space degrades in the very early postoperative period, which could compromise the stability of the bone-implant interface.
引用
收藏
页码:733 / 740
页数:8
相关论文
共 11 条
  • [1] Reduction of disc space distraction after anterior lumbar interbody fusion with autologous iliac crest graft
    Cheung, KMC
    Zhang, YG
    Lu, DS
    Luk, KDK
    Leong, JCY
    SPINE, 2003, 28 (13) : 1385 - 1389
  • [2] Anterior lumbar interbody fusion in comparison with transforaminal lumbar interbody fusion: implications for the restoration of foraminal height, local disc angle, lumbar lordosis, and sagittal balance
    Hsieh, Patrick C.
    Koski, Tyler R.
    O'Shaughnessy, Brian A.
    Sugrue, Patrick
    Salehi, Sean
    Ondra, Stephen
    Liu, John C.
    JOURNAL OF NEUROSURGERY-SPINE, 2007, 7 (04) : 379 - 386
  • [3] The Use of a Transforaminal Lumbar Interbody Fusion (TLIF) Cage Following Inadequate Access to the Disc Space During an Anterior Lumbar Interbody Fusion Procedure
    Obeidallah, Malik
    Hamad, Mousa K.
    Holland, Ryan
    Mammis, Antonios
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (03)
  • [4] Induction of early degeneration of the adjacent segment after posterior lumbar interbody fusion by excessive distraction of lumbar disc space Clinical article
    Kaito, Takashi
    Hosono, Noboru
    Mukai, Yoshihiro
    Makino, Takahiro
    Fuji, Takeshi
    Yonenobu, Kazuo
    JOURNAL OF NEUROSURGERY-SPINE, 2010, 12 (06) : 671 - 679
  • [5] Use of anterior lumbar discectomy and interbody fusion in the management of recurrent lumbar disc herniation and cauda equina syndrome Response
    Chan, Daniel
    Tan, Kimberly-Anne
    Stokes, Oliver M.
    Clarke, Andrew J.
    Sewell, Mathew D.
    Markmann, Yma
    JOURNAL OF NEUROSURGERY-SPINE, 2017, 27 (04) : 350 - 351
  • [6] The correlation between preoperative disc space height and clinical outcomes after anterior lumbar interbody fusion
    Schuler, TC
    Burkus, JK
    Gornet, MF
    Subach, BR
    Zdeblick, TA
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2005, 18 (05): : 396 - 401
  • [7] Provisional Ipsilateral Expandable Rod for Disc Space Distraction in Minimally Invasive Transforaminal Lumbar Interbody Fusion: Operative Technique
    Tumiala, Luis M.
    Clark, Justin C.
    Snyder, Laura A.
    Marciano, Frederick F.
    OPERATIVE NEUROSURGERY, 2014, 10 (04) : 555 - 564
  • [8] Provisional Ipsilateral Expandable Rod for Disc Space Distraction in Minimally Invasive Transforaminal Lumbar Interbody Fusion: Operative Technique COMMENT
    Baron, Eli M.
    Anand, Neel
    OPERATIVE NEUROSURGERY, 2014, 10 (04) : 564 - 564
  • [9] Does Disc Space Height Ofof Fused Segment Affect Adjacent Disc Degeneration in Anterior Lumbar Interbody Fusion? A Radiological Study
    Tang, Sh
    Xu, W.
    IRANIAN RED CRESCENT MEDICAL JOURNAL, 2012, 14 (03) : 139 - 145
  • [10] Injection of Bupivacaine into Disc Space to Detect Painful Nonunion after Anterior Lumbar Interbody Fusion (ALIF) Surgery in Patients with Discogenic Low Back Pain
    Kimura, Seiji
    Ohtori, Seiji
    Orita, Sumihisa
    Inoue, Gen
    Eguchi, Yawara
    Takaso, Masashi
    Ochiai, Nobuyasu
    Kuniyoshi, Kazuki
    Aoki, Yasuchika
    Ishikawa, Tetsuhiro
    Miyagi, Masayuki
    Kamoda, Hiroto
    Suzuki, Miyako
    Sakuma, Yoshihiro
    Kubota, Gou
    Oikawa, Yasuhiro
    Inage, Kazuhide
    Sainoh, Takeshi
    Yamauchi, Kazuyo
    Toyone, Tomoaki
    Nakamura, Junichi
    Kishida, Shunji
    Sato, Jun
    Takahashi, Kazuhisa
    YONSEI MEDICAL JOURNAL, 2014, 55 (02) : 487 - 492