Evaluation of Movement Restriction of Spinal Orthoses Using Inertial Measurement Units

被引:0
|
作者
Fercho, Justyna [1 ]
Krakowiak, Michal [1 ]
Yuser, Rami [2 ]
Szmuda, Tomasz [1 ]
Zielinski, Piotr [1 ]
Szarek, Dariusz [3 ]
Pettersson, Samuel D. [2 ]
Miekisiak, Grzegorz [4 ]
机构
[1] Med Univ Gdansk, Neurosurg Dept, PL-80214 Gdansk, Poland
[2] Med Univ Gdansk, Neurosurg Dept, Sci Circle Neurol & Neurosurg, PL-80214 Gdansk, Poland
[3] Marciniaks Hosp, Dept Neurosurg, PL-54049 Wroclaw, Poland
[4] Opole Univ, Inst Med, PL-45052 Opole, Poland
关键词
spine; motion analysis; wearable sensors; biomechanics; brace; orthosis; OSTEOPOROTIC COMPRESSION FRACTURES; LUMBOSACRAL ORTHOSES;
D O I
10.3390/ijerph192416515
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Despite the frequent use of orthopedic braces or spine stabilizers in diseases such as kyphosis, lordosis, and scoliosis, as well as in the case of injuries and rehabilitation after surgeries, there is no clear evidence of their proper stabilization of the spine while carrying out daily activities. This study sought to assess the spine's mobility while wearing three different orthopedic braces while performing basic tasks. Ten healthy subjects were enrolled. Three Inertial Measurement Units (IMUs) were attached superficially along the spine at approximate levels: cervical (C7), between thoracic (T8) and lumbar (L3), and sacrum. The angle between sensors was monitored to provide data on the sagittal profile. In addition, the displacement of the spine's longitudinal axis was measured (rotation). There are three types of orthopedic braces: the semi-rigid Hohmann corset, the Jewett brace, and the Thoracolumbar Fixed Spinal Orthosis (TLSO). Four tasks were monitored: standing, sitting, walking, and picking up an item from the floor with one hand. All braces provided a similar level of stability in both the sagittal plane and rotational axis while lifting an object. On the other hand, while walking and sitting, the TLSO was the only orthosis providing a statistically significant rigidity in the sagittal plane. When performing a more voluntary task, the measured rigidity of softer braces was significantly increased when compared with more involuntary tasks. A certain degree of motion restriction with spinal orthoses may come from the feedback pressure, which stimulates paraspinal muscles to contract and thus increases the overall rigidity of the trunk.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Evaluation of spinal posture during gait with inertial measurement units
    Digo, Elisa
    Pierro, Giuseppina
    Pastorelli, Stefano
    Gastaldi, Laura
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2020, 234 (10) : 1094 - 1105
  • [2] Estimating Movement Smoothness From Inertial Measurement Units
    Melendez-Calderon, Alejandro
    Shirota, Camila
    Balasubramanian, Sivakumar
    FRONTIERS IN BIOENGINEERING AND BIOTECHNOLOGY, 2021, 8
  • [3] ASSESSMENT OF LUMBAR SPINAL MOBILITY USING INERTIAL MEASUREMENT UNITS IN AXIAL SPONDYLOARTHRITIS
    Franco, L.
    Ward, W.
    Sengupta, R.
    Cazzola, D.
    CLINICAL AND EXPERIMENTAL RHEUMATOLOGY, 2018, 36 (04) : 756 - 756
  • [4] Objective Evaluation of Oral Presentation Skills Using Inertial Measurement Units
    Sessa, Salvatore
    Kong, Weisheng
    Zhang, Di
    Cosentino, Sarah
    Manawadu, Udara
    Kawasaki, Motoji
    Thomas, George Thuruthel
    Suzuki, Tomohiro
    Tsumura, Ryosuke
    Takanishi, Atsuo
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 3117 - 3120
  • [5] A Methodology for the Performance Evaluation of Inertial Measurement Units
    Sessa, Salvatore
    Zecca, Massimiliano
    Lin, Zhuohua
    Bartolomeo, Luca
    Ishii, Hiroyuki
    Takanishi, Atsuo
    JOURNAL OF INTELLIGENT & ROBOTIC SYSTEMS, 2013, 71 (02) : 143 - 157
  • [6] A Methodology for the Performance Evaluation of Inertial Measurement Units
    Salvatore Sessa
    Massimiliano Zecca
    Zhuohua Lin
    Luca Bartolomeo
    Hiroyuki Ishii
    Atsuo Takanishi
    Journal of Intelligent & Robotic Systems, 2013, 71 : 143 - 157
  • [7] Gait evaluation using inertial measurement units in subjects with Parkinson's disease
    Zago, Matteo
    Sforza, Chiarella
    Pacifici, Ilaria
    Cimolin, Veronica
    Camerota, Filippo
    Celletti, Claudia
    Condoluci, Claudia
    De Pandis, Maria Francesca
    Galli, Manuela
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2018, 42 : 44 - 48
  • [8] Prediction of movement in handball with the use of inertial measurement units and machine learning
    Lentz-Nielsen, Nicki
    Hart, Brian
    Samani, Afshin
    SPORTS BIOMECHANICS, 2023,
  • [9] Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity
    Al-Amri, Mohammad
    Nicholas, Kevin
    Button, Kate
    Sparkes, Valerie
    Sheeran, Liba
    Davies, Jennifer L.
    SENSORS, 2018, 18 (03):
  • [10] Ambulatory measurement of elbow kinematics using inertial measurement units
    Ang, Wei Sin
    Chen, I-Ming
    Yuan, Qilong
    2013 IEEE/ASME INTERNATIONAL CONFERENCE ON ADVANCED INTELLIGENT MECHATRONICS (AIM): MECHATRONICS FOR HUMAN WELLBEING, 2013, : 756 - 761