Impact of aortic valve calcification severity on device success after transcatheter aortic valve replacement

被引:12
|
作者
Larroche, Jeremy [1 ,6 ]
Panh, Loic [8 ]
Lhermusier, Thibault [1 ,4 ,6 ]
Bataille, Vincent [1 ]
Marachet, Marie-Agnes [2 ,7 ]
Chollet, Thomas [4 ,6 ]
Petermann, Antoine [8 ]
Bouisset, Frederic [1 ,6 ]
Boudou, Nicolas [9 ]
Marcheix, Bertrand [3 ,5 ,6 ]
Rousseau, Herve [2 ,3 ,7 ]
Galinier, Michel [1 ,3 ]
Carrie, Didier [1 ,2 ,4 ]
Lairez, Olivier [1 ,2 ,3 ,6 ]
Lavie-Badie, Yoan [1 ,2 ,6 ,10 ]
机构
[1] Univ Hosp Rangueil, Dept Cardiol, Toulouse, France
[2] Toulouse Univ Hosp, Cardiac Imaging Ctr, Toulouse, France
[3] Univ Paul Sabatier, Med Sch Rangueil, Toulouse, France
[4] Univ Paul Sabatier, Med Sch Purpan, Toulouse, France
[5] Univ Hosp Rangueil, Dept Cardiac Surg, Toulouse, France
[6] Univ Hosp Rangueil, Heart Valve Ctr, Toulouse, France
[7] Univ Hosp Rangueil, Dept Radiol, Toulouse, France
[8] Clin Pasteur, Toulouse, France
[9] Clin St Augustin, Bordeaux, France
[10] Toulouse Univ Hosp, Dept Cardiol, 1 Ave Jean Poulhes, F-31059 Toulouse 9, France
来源
关键词
Aortic valve disease; Calcium scoring; CT scanning; Paravalvular leak; TAVR; PARAVALVULAR REGURGITATION; RISK PATIENTS; IMPLANTATION; SCORE; STENOSIS; OUTCOMES; SOCIETY;
D O I
10.1007/s10554-019-01759-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aortic valvular calcium score (AVCS) can identify severe aortic stenosis (AS) and provide powerful prognostic information. In severe and symptomatic AS, patients can be referred for a transcatheter aortic valve replacement (TAVR). The aim of this study was to determine whether AVCS, measured on the preoperative contrast enhanced multislice computed tomography (MSCT), is associated with device success (DS), major adverse cardiac events (MACEs) and paravalvular leak (PVL) after TAVR. Three hundred and fifty-two consecutive patients who underwent TAVR with a preoperative standardised contrast enhanced MSCT were included in the study. Valvular calcification detection was defined by adding + 100 Hounsfield Unit (HU) to mean HU determined by a region of interest placed in the contrast enhanced ascending aorta. AVCS was then indexed to the aortic annulus surface (AVCSi). Endpoints were DS and 30-day MACE according to Valve Academic Research Consortium-2 consensus document, and moderate to severe PVL. DS was obtained for 305 patients. In multivariate analysis, AVCSi was negatively and independently associated with DS: OR = 0.99, 95% CI 0.99-0.99, p = 0.03. In the subgroup analysis, this association was particularly relevant with self-expanding prostheses [n = 151 (43%), p = 0.018] and in the cases of asymmetric calcium valvular distribution [n = 283 (80%), p 0.002]. There was no association between MACE and AVCS (p = 0.953) and AVCSi (p = 0.757). PVL was positively associated with AVCS (p < 0.001) and AVCSi (p < 0.001). In conclusion, in TAVR, AVCS, measured on preoperative contrast enhanced MSCT, is significantly associated with DS and PVL, but not with 30-day MACE. Its routine use could be relevant to appreciate success chances of TAVR.
引用
收藏
页码:731 / 740
页数:10
相关论文
共 50 条
  • [1] Impact of aortic valve calcification severity on device success after transcatheter aortic valve replacement
    Jeremy Larroche
    Loïc Panh
    Thibault Lhermusier
    Vincent Bataille
    Marie-Agnès Marachet
    Thomas Chollet
    Antoine Petermann
    Frederic Bouisset
    Nicolas Boudou
    Bertrand Marcheix
    Hervé Rousseau
    Michel Galinier
    Didier Carrié
    Olivier Lairez
    Yoan Lavie-Badie
    The International Journal of Cardiovascular Imaging, 2020, 36 : 731 - 740
  • [2] Impact of aortic valve calcification severity on device success after trans catheter aortic valve replacement
    Larroche, J.
    Panh, L.
    Lhermusier, T.
    Lairez, O.
    Bataille, V.
    Marachet, M. -A.
    Chollet, T.
    Petermann, A.
    Bouisset, F.
    Boudou, N.
    Marcheix, B.
    Rousseau, H.
    Galinier, M. -A.
    Carrie, D.
    Lavie-Badie, Y.
    EUROPEAN HEART JOURNAL, 2019, 40 : 504 - 504
  • [3] Correlation of aortic valve calcification severity with the degree of aortic valve regurgitation after transcatheter aortic valve replacement
    Koos, R.
    Mahnken, A. H.
    Brehmer, K.
    Muehlenbruch, G.
    Dohmen, G.
    Autschbach, R.
    Kelm, M.
    Hoffmann, R.
    EUROPEAN HEART JOURNAL, 2009, 30 : 689 - 690
  • [4] Impact of aortic valve calcification on new onset conduction disturbance after transcatheter aortic valve replacement
    Wang, Y.
    EUROPEAN HEART JOURNAL, 2018, 39 : 24 - 24
  • [5] Impact of Aortic Valve Calcification Severity on Four-Year Results of Patients Undergoing Transcatheter Aortic Valve Replacement
    Koos, Ralf
    Reinartz, Sebastian
    Herpertz, Ralf
    Lotfi, Shahram
    Autschbach, Ruediger
    Marx, Nikolaus
    Hoffmann, Rainer
    CIRCULATION, 2013, 128 (22)
  • [6] IMPACT OF AORTIC VALVE CALCIFICATION SEVERITY ON FIVE-YEAR RESULTS OF PATIENTS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Koos, Ralf
    Reinartz, Sebastian
    Lotfi, Shahram
    Autschbach, Ruediger
    Hoffmann, Rainer
    Marx, Nikolaus
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 63 (12) : A1959 - A1959
  • [7] Association of aortic valve calcification severity with the degree of aortic regurgitation after transcatheter aortic valve implantation
    Koos, Ralf
    Mahnken, Andreas Horst
    Dohmen, Guido
    Brehmer, Kathrin
    Guenther, Rolf W.
    Autschbach, Ruediger
    Marx, Nikolaus
    Hoffmann, Rainer
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2011, 150 (02) : 142 - 145
  • [8] IMPACT OF AORTIC VALVE CALCIFICATION SEVERITY IN PATIENTS WITH LOW-FLOW LOWGRADIENT AORTIC STENOSIS UNDERGOING TRANSCATHETER AORTIC VALVE REPLACEMENT
    Singh, Ranbir
    Chopra, Lakshay
    Sperling, Dylan
    Dalsania, Ankur
    Ueyama, Hiroki
    Prandi, Francesca Romana
    Passaniti, Giulia
    Sharma, Samin K.
    Kini, Annapoorna Subhash
    Lerakis, Stamatios
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2024, 83 (13) : 965 - 965
  • [9] Impact of Aortic Valve Calcification on Acute Elastic Recoil of a Balloon-Expandable Valve After Transcatheter Aortic Valve Replacement
    Yoshihara, Nagataka
    Akahori, Hirokuni
    Tanaka, Takamasa
    Yanaka, Koji
    Kimura, Toshio
    Miki, Kojiro
    Imanaka, Takahiro
    Ishihara, Masaharu
    CIRCULATION, 2019, 140
  • [10] Impact of surgical aortic valve replacement volume on tamponade after transcatheter aortic valve replacement
    Agrawal, Ankit
    Shekhar, Shashank
    Isogai, Toshiaki
    Ramu, Shivabalan Kathavarayan
    Badwan, Osamah
    Yun, James J.
    Harb, Serge C.
    Krishnaswamy, Amar
    Kapadia, Samir R.
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2024, 14 (02) : 311 - 313