Measuring protein synthesis by mass isotopomer distribution analysis (MIDA)

被引:58
|
作者
Papageorgopoulos, C [1 ]
Caldwell, K
Shackleton, C
Schweingrubber, H
Hellerstein, MK
机构
[1] Univ Calif Berkeley, Dept Nutr Sci, Berkeley, CA 94720 USA
[2] Childrens Hosp Oakland, Res Inst, Oakland, CA 94609 USA
[3] Glycomed Inc, Alameda, CA 94501 USA
[4] Univ Calif San Francisco, San Francisco Gen Hosp, Dept Med, Div Endocrinol & Metab, San Francisco, CA 94110 USA
关键词
D O I
10.1006/abio.1998.2958
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The measurement of protein kinetics by isotopic techniques has been hindered by the long-standing difficulty of accurately measuring the isotope content of the biosynthetic precursor pool (aminoacyl-tRNA in tissues). Mass isotopomer distribution analysis (MIDA) is a stable isotope-mass spectrometric (MS) technique for measuring biosynthetic precursor enrichments from measurements on a polymeric product, based on combinatorial probabilities of labeled and unlabeled monomeric subunits, Proteins contain complex isotopomer patterns as a result of their relatively high molecular mass, however, so that resolution of the individual mass isotopomers in the polymeric product (an analytic requirement for MIDA) is technically difficult. An approach for measuring protein synthesis by MIDA is described and tested here: First, in vitro, using a synthetic peptide present in human serum albumin; and then, in vivo, for albumin synthetic rate in rats. A peptide contained in human serum albumin (SVVLLLR) and theoretically recoverable from trypsin/chymotrypsin proteolysis was synthesized by solid-phase peptide synthesis using known mixtures of natural abundance and [5,5,5-H-2(3)]leucine, Additionally, enriched and natural abundance peptides were mixed in vitro to simulate in vivo biosynthesis and to address problems of instrument accuracy, precision, and data management. The mass isotopomer patterns of the synthetic peptides were analyzed using electrospray ionization (ESI) with both magnetic sector and quadrupole mass analyzers. The resolution of the magnetic sector was superior to that of the quadrupole instrument, but accuracy and precision in the measurement of mass isotopomer abundances and kinetic parameters were comparable and both gave values close to those predicted. Next, rats were infused with [5,5,5-H-2(3)]leucine intravenously, and a leucine-rich peptide was isolated and purified from trypsin-digested rat serum albumin (RHPDYSVSLLLR, 1456 Da) and then analyzed by ESI-MS using a magnetic sector instrument. Precursor pool enrichments and fractional synthetic rates (0.45 +/- 0.03 day(-1), t(1/2) = 1.53 +/- 0.09 days) were calculated. Biosynthetic rates of rat serum albumin were congruent with previously published values. In summary, measurement of protein synthesis and precursor pool enrichments by MIDA is technically feasible and practical in vivo using proteolytically derived peptides and ESI-MS analysis. (C) 1999 Academic Press.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 50 条
  • [1] MEASUREMENT OF MUSCLE MYOSIN SYNTHESIS BY MASS ISOTOPOMER DISTRIBUTION ANALYSIS (MIDA)
    PAPAGEORGOPOULOS, C
    CALDWELL, KA
    SILER, SO
    NEESE, RA
    HELLERSTEIN, MK
    FASEB JOURNAL, 1995, 9 (04): : A864 - A864
  • [2] Limitations of mass isotopomer distribution analysis (MIDA) for estimating gluconeogenesis (f)
    Previs, SF
    Cline, GW
    Shulman, GI
    DIABETES, 1998, 47 : A284 - A284
  • [3] Mass isotopomer distribution analysis (MIDA) for studying intermediary nutrient metabolism
    Bequette, B. J.
    JOURNAL OF DAIRY SCIENCE, 2005, 88 : 242 - 242
  • [4] MEASUREMENT OF GLUCONEOGENESIS INVIVO USING MASS ISOTOPOMER DISTRIBUTION ANALYSIS (MIDA)
    FAIX, D
    NEESE, R
    HELLERSTEIN, MK
    FASEB JOURNAL, 1992, 6 (05): : A1788 - A1788
  • [5] MASS ISOTOPOMER DISTRIBUTION ANALYSIS (MIDA) FOR MEASURING GLUCONEOGENESIS (GNG) - TESTING ASSUMPTIONS AND POTENTIAL THEORETICAL AND PRACTICAL PROBLEMS
    NEESE, RA
    MILLS, M
    SCHWARZ, JM
    COUTLANGUS, M
    HELLERSTEIN, MK
    FASEB JOURNAL, 1994, 8 (05): : A919 - A919
  • [6] Mass isotopomer distribution analysis (MIDA) for studying intermediary nutrient metabolism.
    Bequette, B. J.
    JOURNAL OF ANIMAL SCIENCE, 2005, 83 : 242 - 242
  • [7] Software LS-MIDA for efficient mass isotopomer distribution analysis in metabolic modelling
    Ahmed, Zeeshan
    Zeeshan, Saman
    Huber, Claudia
    Hensel, Michael
    Schomburg, Dietmar
    Muench, Richard
    Eisenreich, Wolfgang
    Dandekar, Thomas
    BMC BIOINFORMATICS, 2013, 14
  • [8] MEASUREMENT OF ENDOGENOUS SYNTHESIS OF SERUM-CHOLESTEROL IN RATS AND HUMANS USING MASS ISOTOPOMER DISTRIBUTION ANALYSIS (MIDA)
    NEESE, R
    FAIX, D
    KLETKE, C
    WU, K
    WANG, A
    SHACKLETON, CHL
    HELLERSTEIN, MK
    FASEB JOURNAL, 1992, 6 (05): : A1788 - A1788
  • [9] Software LS-MIDA for efficient mass isotopomer distribution analysis in metabolic modelling
    Zeeshan Ahmed
    Saman Zeeshan
    Claudia Huber
    Michael Hensel
    Dietmar Schomburg
    Richard Münch
    Wolfgang Eisenreich
    Thomas Dandekar
    BMC Bioinformatics, 14
  • [10] A simplified calculation procedure for mass isotopomer distribution analysis (MIDA) based on multiple linear regression
    Fernandez-Fernandez, Mario
    Rodriguez-Gonzalez, Pablo
    Garcia Alonso, J. Ignacio
    JOURNAL OF MASS SPECTROMETRY, 2016, 51 (10): : 980 - 987