Comparison of the Diagnostic Performance of a Rapid Antigen Test with Real-Time Polymerase Chain Reaction for Detection of SARS-CoV-2 Among Patients Diagnosed with COVID-19 at Selected Hospitals in Addis Ababa, Ethiopia

被引:3
|
作者
Desalegn, Zelalem [1 ,8 ]
Sebre, Shemse [1 ]
Yohannes, Meron [2 ]
Seman, Aminu [1 ]
Shiferaw, Welelta [3 ]
Ademe, Muluneh [1 ]
Biazin, Habtamu [1 ]
Firdawoke, Ededia [1 ]
Asemamaw, Yehenew [1 ]
Teka, Brhanu [1 ]
Teshome, Seifegebriel [1 ]
Amogne, Wondwossen [4 ]
Addissie, Adamu [5 ,6 ]
Gebrehiwot, Yirgu [7 ]
Kantelhardt, Eva [6 ]
Abebe, Tamrat [1 ]
机构
[1] Addis Ababa Univ, Coll Hlth Sci, Sch Med, Dept Microbiol Immunol & Parasitol, Addis Ababa, Ethiopia
[2] Addis Ababa Univ, Coll Hlth Sci, Dept Med Lab Sci, Addis Ababa, Ethiopia
[3] Addis Ababa Univ, Coll Hlth Sci, Sch Med, Dept Psychiat, Addis Ababa, Ethiopia
[4] Addis Ababa Univ, Coll Hlth Sci, Sch Med, Dept Internal Med, Addis Ababa, Ethiopia
[5] Addis Ababa Univ, Coll Hlth Sci, Sch Publ Hlth, Addis Ababa, Ethiopia
[6] Martin Luther Univ Halle Wittenberg, Inst Med Epidemiol Biostat & Informat, Halle, Germany
[7] Addis Ababa Univ, Coll Hlth Sci, Sch Med, Dept Obstet & Gynecol, Addis Ababa, Ethiopia
[8] Addis Ababa Univ, Coll Hlth Sci, Dept Microbiol Immunol & Parasitol, POB 9086, Addis Ababa, Ethiopia
来源
关键词
SARS-CoV-2; COVID-19; antigen test;
D O I
10.2147/IDR.S353844
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: When faced with a public health problem such as the COVID-19 pandemic, devising a test with an accurate and rapid diagnostic capacity is critical to contain the disease. We compared the diagnostic performance of a rapid antigen test in comparison with a reference method, namely a real-time polymerase chain reaction (RT-PCR) assay.Methods: We enrolled patients with confirmed COVID-19 from two selected hospital in Addis Ababa, Ethiopia, between January and November 2021. We assessed the performance of the Standard Q COVID-19 Ag Kit (SD Biosensor, Republic of Korea) in 200 nasopharyngeal and nasal swab samples.Results: Out of the 200 samples utilized for the diagnostic performance evaluation, equal proportion of the samples were confirmed positive and negative for SARS-CoV-2 based on RT-PCR. Of the 100 confirmed positive cases, 95 showed positive results with the rapid antigen test, yielding a sensitivity of 95% (95% confidence interval [CI] 88.7-98.4%). Of the 100 confirmed negative cases, there were three false-positive results, yielding a specificity of 97% (95% CI 91.5-99.4%). The sensitivity of the rapid antigen test was higher for samples with an RT-PCR cycle threshold (Ct) value <= 25 compared with samples with a higher Ct value.Conclusion: The finding demonstrated that the detection capacity of the Standard Q COVID-19 Ag Test meets the requirements set by the Ministry of Health Ethiopia. The high sensitivity and specificity of the test device indicate the possibility of using it for diagnostic and clinical purposes in resource-constrained settings such as Ethiopia.
引用
收藏
页码:4299 / 4305
页数:7
相关论文
共 50 条
  • [1] Evaluation of the performance of Panbio™ COVID-19 antigen rapid diagnostic test for the detection of SARS-CoV-2 in suspected patients in Ethiopia
    Dessalegn, Dejene
    Tola, Edosa Kifle
    Tamiru, Afework
    Zerfu, Biruk
    SAGE OPEN MEDICINE, 2022, 10
  • [2] SARS-CoV-2 variant typing using real-time reverse transcription-polymerase chain reaction-based assays in Addis Ababa, Ethiopia
    Gmeskel, Wodneh
    Desta, Kassu
    Diriba, Regasa
    Belachew, Mahlet
    Evans, Martin
    Cantarelli, Vlademir
    Urrego, Maritza
    Sisay, Abay
    Gebreegziabxier, Atsbeha
    Abera, Adugna
    IJID REGIONS, 2024, 11
  • [3] Evaluation of the Diagnostic Performance of SARS-CoV-2 Rapid Antigen Tests in COVID-19 Patients
    Tuyji Tok, Yesim
    Dinc, Harika Oyku
    Akcin, Ruveyda
    Dasdemir, Ferhat Osman
    Eryigit, Onder Yuksel
    Demirci, Mehmet
    Gareayaghi, Nesrin
    Kuskucu, Mert Ahmet
    Kocazeybek, Bekir Sami
    MIKROBIYOLOJI BULTENI, 2022, 56 (02): : 251 - 262
  • [4] Rapid Serological Assays and SARS-CoV-2 Real-Time Polymerase Chain Reaction Assays for the Detection of SARS-CoV-2: Comparative Study
    Paradiso, Angelo Virgilio
    De Summa, Simona
    Loconsole, Daniela
    Procacci, Vito
    Sallustio, Anna
    Centrone, Francesca
    Silvestris, Nicola
    Cafagna, Vito
    De Palma, Giuseppe
    Tufaro, Antonio
    Garrisi, Vito Michele
    Chironna, Maria
    JOURNAL OF MEDICAL INTERNET RESEARCH, 2020, 22 (10)
  • [5] Evaluation of Rapid Antigen Test Results and Real-time Reverse Transcription Polymerase Chain Reaction for the Laboratory Diagnosis of SARS-CoV-2
    Tanriverdi Cayci, Yeliz
    Seyfi, Zeliha
    Hacieminoglu Ulker, Kubra
    Gur Vural, Demet
    Bilgin, Kemal
    Akdemir, Hizir Ufuk
    Akyuz Ozkan, Esra
    Birinci, Asuman
    MEDITERRANEAN JOURNAL OF INFECTION MICROBES AND ANTIMICROBIALS, 2023, 12
  • [6] Diagnostic Performance of Rapid Antigen Testing for SARS-CoV-2: The COVid-19 AntiGen (COVAG) study
    Wertenauer, Christoph
    Brenner Michael, Geovana
    Dressel, Alexander
    Pfeifer, Caroline
    Hauser, Ulrike
    Wieland, Eberhard
    Mayer, Christian
    Mutschmann, Caren
    Roskos, Martin
    Wertenauer, Hans-Joerg
    Moissl, Angela P.
    Lorkowski, Stefan
    Maerz, Winfried
    FRONTIERS IN MEDICINE, 2022, 9
  • [7] Comparison of Rapid Antigen Detection Test with Reverse Transcription Polymerase Chain Reaction in Highly COVID-19 Patients
    Afridi, Muhammad Abdur Rahman
    Ali, Zafar
    Iqbal, Naveed
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2023, 33 (09): : 1058 - 1061
  • [8] Diagnostic Efficacy of COVID-19 Rapid Antigen Detection Card in Diagnosis of SARS-CoV-2
    Selvabai, Alice P. R.
    Koshy, Lino, V
    Shanmugam, Priyadarshini
    JOURNAL OF LABORATORY PHYSICIANS, 2022, 14 (03) : 324 - 328
  • [9] Evaluation of COVID-19 Antigen Fluorescence Immunoassay Test for Rapid Detection of SARS-CoV-2
    Kiro, Vandana Vijayeta
    Gupta, Ankesh
    Singh, Parul
    Sharad, Neha
    Khurana, Surbhi
    Prakash, S.
    Dar, Lalit
    Malhotra, Rajesh
    Wig, Naveet
    Kumar, Arvind
    Trikha, Anjan
    Mathur, Purva
    JOURNAL OF GLOBAL INFECTIOUS DISEASES, 2021, 13 (02) : 91 - 93
  • [10] SARS-CoV-2 antigen rapid detection tests: test performance during the COVID-19 pandemic and the impact of COVID-19 vaccination
    Wagenhaeuser, Isabell
    Knies, Kerstin
    Pscheidl, Tamara
    Eisenmann, Michael
    Flemming, Sven
    Petri, Nils
    Mcdonogh, Miriam
    Scherzad, Agmal
    Zeller, Daniel
    Gesierich, Anja
    Seitz, Anna Katharina
    Taurines, Regina
    Ernestus, Ralf-Ingo
    Forster, Johannes
    Weismann, Dirk
    Weissbrich, Benedikt
    Liese, Johannes
    Hartel, Christoph
    Kurzai, Oliver
    Doelken, Lars
    Gabel, Alexander
    Krone, Manuel
    EBIOMEDICINE, 2024, 109