A comprehensive assessment of curling effects in stainless steel bolted connections

被引:8
|
作者
Sobrinho, Kelvin de P. [1 ]
da Silva, Andre T. [2 ]
Rodrigues, Monique C. [2 ]
Henriques, Jose A. [3 ]
Vellasco, Pedro C. G. da S. [2 ]
de Lima, Luciano R. O. [2 ]
机构
[1] State Univ Rio de Janeiro UERJ, Civil Engn Postgrad Program PGECIV, Rio De Janeiro, Brazil
[2] State Univ Rio de Janeiro UERJ, Struct Engn Dept, Rio De Janeiro, Brazil
[3] Hasselt Univ, Fac Engn Technol, B-3500 Hasselt, Belgium
关键词
Bolted connections; Experimental tests; Numerical analysis; Curling effects; Stainless steel;
D O I
10.1016/j.tws.2022.109387
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
There has been a significant increase in stainless steel investigations related to steel construction in the last few years, contemplating numerical and experimental studies. This fact is associated with the excellent properties these materials can provide compared to carbon steel, such as corrosion resistance, durability, fire resistance, and added aesthetic value. On the other hand, the current standards and design codes are still mostly based on carbon steel analogies that do not consider stainless steel's hardening response. The stainless steel has a distinct structural behaviour; its stress versus strain curve is nonlinear from low-stress levels and does not present a well-defined yield plateau. The present investigation was centred on developing experimental and numerical tests to clarify the response of splice connections. The experiments and numerical models involved stainless steel thin-plates connected by a single bolt (with two shear planes). Comparisons with current design codes and the new stainless steel design manual recommendations were also performed. The main aim of the performed studies was to investigate the influence of the curling effect over the bolted connections strength since this phenomenon can reduce the connection load-carrying capacity. The main investigated parameters were the end distance, e(1), plate thickness, t and the adoption of stiffness plates. The results indicated that the curling effects were not significant for connections with e(1)/d ratios less than 3.5. A transition zone was also observed from this value up to 3.0, where the connections ultimate strength was only slightly influenced. Comparing thin-plate connections of the same geometry, with and without curling effects, led to 8% and 20% reductions of the ultimate capacity of austenitic and ferritic bolted connections. Alternatively, in thick-plate connections (5 mm), this effect could not be observed. The present investigation confirmed that a solution to minimize curling effects could be achieved using plate lips with heights equal to one-third of the plate width.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] Bearing-curling interaction of austenitic stainless steel thin sheet bolted connections
    Jiang, Ke
    Li, Shuai
    Zhong, Yukai
    Zhao, Ou
    THIN-WALLED STRUCTURES, 2024, 200
  • [2] Numerical simulation and effect of curling on bolted connections in cold-formed stainless steel
    Kim, Tae Soo
    Han, Byum Seok
    ISIJ INTERNATIONAL, 2007, 47 (06) : 920 - 929
  • [3] Bearing failure in stainless steel bolted connections
    Salih, E. L.
    Gardner, L.
    Nethercot, D. A.
    ENGINEERING STRUCTURES, 2011, 33 (02) : 549 - 562
  • [4] BEHAVIOUR AND DESIGN OF STAINLESS STEEL BOLTED CONNECTIONS
    Nethercot, D. A.
    Salih, E. L.
    Gardner, L.
    3RD INTERNATIONAL FORUM ON ADVANCES IN STRUCTURAL ENGINEERING: ADVANCES IN RESEARCH AND PRACTICE OF STEEL STRUCTURES, 2009, : 1 - 18
  • [5] Numerical study of bolted connections in stainless steel
    Salih, E. L.
    Gardner, L.
    Nethercot, D. A.
    STEEL CONCRETE COMPOSITE AND HYBRID STRUCTURES, 2009, : 625 - 632
  • [6] Bearing Strength of Stainless Steel Bolted Connections
    Yang, Lu
    Wang, Yuanqing
    Guan, Jian
    Zhang, Yong
    Shi, Yongjiu
    ADVANCES IN STRUCTURAL ENGINEERING, 2015, 18 (07) : 1051 - 1062
  • [7] BOLTED AND WELDED STAINLESS-STEEL CONNECTIONS
    ERRERA, SJ
    POPOWICH, DW
    WINTER, G
    JOURNAL OF THE STRUCTURAL DIVISION-ASCE, 1974, 100 (NST6): : 1279 - 1296
  • [8] Preloaded bolted connections made of stainless steel
    Stranghoener, Natalie
    Jungbluth, Dominik
    Afzali, Nariman
    Abraham, Christoph
    STAHLBAU, 2020, 89 (04) : 326 - 338
  • [9] Behaviour of duplex stainless steel bolted connections
    Dobric, Jelena
    Cai, Yancheng
    Young, Ben
    Rossi, Barbara
    THIN-WALLED STRUCTURES, 2021, 169
  • [10] Analysis of the behaviour of stainless steel bolted connections
    Bouchair, A.
    Averseng, J.
    Abidelah, A.
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (11) : 1264 - 1274