Poor Reliability of Wrist Blood Pressure Self-Measurement at Home: A Population-Based Study

被引:41
|
作者
Casiglia, Edoardo [1 ]
Tikhonoff, Valerie [1 ]
Albertini, Federica [1 ]
Palatini, Paolo [1 ]
机构
[1] Univ Padua, Dept Med, Via Giustiniani 2, Padua, Italy
关键词
blood pressure; epidemiology; heart; methods; wrist; TERMINAL DIGIT PREFERENCE; PULSE PRESSURE; POSITION SENSOR; ARM POSITION; RISK-FACTORS; HYPERTENSION; IMPACT; DEVICE; VALIDATION; ACCURACY;
D O I
10.1161/HYPERTENSIONAHA.116.07961
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
The reliability of blood pressure measurement with wrist devices, which has not previously been assessed under real-life circumstances in general population, is dependent on correct positioning of the wrist device at heart level. We determined whether an error was present when blood pressure was self-measured at the wrist in 721 unselected subjects from the general population. After training, blood pressure was measured in the office and self-measured at home with an upper-arm device (the UA-767 Plus) and a wrist device (the UB-542, not provided with a position sensor). The upper-arm-wrist blood pressure difference detected in the office was used as the reference measurement. The discrepancy between office and home differences was the home measurement error. In the office, systolic blood pressure was 2.5% lower at wrist than at arm (P=0.002), whereas at home, systolic and diastolic blood pressures were higher at wrist than at arm (+5.6% and +5.4%, respectively; P<0.0001 for both); 621 subjects had home measurement error of at least +/- 5 mmHg and 455 of at least +/- 10 mmHg (bad measurers). In multivariable linear regression, a lower cognitive pattern independently determined both the systolic and the diastolic home measurement error and a longer forearm the systolic error only. This was confirmed by logistic regression having bad measurers as dependent variable. The use of wrist devices for home self-measurement, therefore, leads to frequent detection of falsely elevated blood pressure values likely because of a poor memory and rendition of the instructions, leading to the wrong position of the wrist.
引用
收藏
页码:896 / 903
页数:8
相关论文
共 50 条
  • [1] POOR RELIABILITY OF WRIST BLOOD PRESSURE SELF-MEASUREMENT AT HOME. A POPULATION-BASED STUDY
    Tikhonoff, Valerie
    Casiglia, Edoardo
    Albertini, Federica
    Palatini, Paolo
    JOURNAL OF HYPERTENSION, 2016, 34 : E85 - E85
  • [2] Accuracy and reliability of wrist-cuff devices for self-measurement of blood pressure
    Kikuya, M
    Chonan, K
    Imai, Y
    Goto, E
    Ishii, M
    JOURNAL OF HYPERTENSION, 2002, 20 (04) : 629 - 638
  • [3] WRIST BLOOD PRESSURE SELF-MEASUREMENT AT HOME IS UNRELIABLE. RESULTS FROM THE POPULATION-BASED "GROWING OLD WITH LESS DISEASE ENHANCING NEUROFUNCTIONS'' (GOLDEN) STUDY
    Tikhonoff, V.
    Casiglia, E.
    Palatini, P.
    JOURNAL OF HYPERTENSION, 2016, 34 : E69 - E69
  • [4] THE DUBENDORF STUDY - A POPULATION-BASED INVESTIGATION ON NORMAL VALUES OF BLOOD-PRESSURE SELF-MEASUREMENT
    WEISSER, B
    GRUNE, S
    BURGER, R
    BLICKENSTORFER, H
    ISELI, J
    MICHELSEN, SH
    OPRAVIL, R
    RAGETH, S
    STURZENEGGER, ER
    WALKER, P
    WIDMER, W
    VETTER, W
    JOURNAL OF HUMAN HYPERTENSION, 1994, 8 (04) : 227 - 231
  • [5] Self-measurement of blood pressure in the office and at home
    Myers, MG
    Parati, G
    JOURNAL OF HYPERTENSION, 2003, 21 (12) : 2223 - 2225
  • [6] Self-measurement of blood pressure at home: Is it reliable?
    Dilek, Melda
    Adibelli, Zelal
    Aydogdu, Turkan
    Koksal, Ali Riza
    Cakar, Burcu
    Akpolat, Tekin
    BLOOD PRESSURE, 2008, 17 (01) : 34 - 41
  • [7] Wrist-cuff blood pressure home self-measurement in diabetic patients: Comparable to ambulatory blood pressure monitoring
    Khoshdel, A. R.
    Carney, S. L.
    HYPERTENSION, 2007, 49 (06) : 1470 - 1470
  • [8] Self-Measurement of Blood Pressure at Home in the Management of Hypertension
    Celis, Hilde
    Den Hond, Elly
    Staessen, Jan
    CLINICAL MEDICINE & RESEARCH, 2005, 3 (01) : 19 - 26
  • [9] Epidemiology of hypertension based on ambulatory blood pressure monitoring and self-measurement of blood pressure at home
    Imai, Y
    Okubo, T
    Asayama, K
    Metoki, H
    Kikuya, M
    Hashimoto, J
    Ugajin, T
    Totsune, K
    Satohe, H
    JOURNAL OF HEALTH SCIENCE, 2004, 50 (02) : 113 - 119
  • [10] Reproducibility of Nocturnal Blood Pressure Assessed by Self-Measurement of Blood Pressure at Home
    Keiko Hosohata
    Masahiro Kikuya
    Takayoshi Ohkubo
    Hirohito Metoki
    Kei Asayama
    Ryusuke Inoue
    Taku Obara
    Junichiro Hashimoto
    Kazuhito Totsune
    Haruhisa Hoshi
    Hiroshi Satoh
    Yutaka Imai
    Hypertension Research, 2007, 30 : 707 - 712