Purpose: Low-dose-rate total body irradiation (LDR TBI) in infants possesses unique challenges because of the setup limitations imposed by anesthesia. We present an LDR TBI method with an anteroposterior/posteroanterior arrangement and dose rate < 10 cGy/minute for infants (thickness <14 cm) without the use of a beam attenuator. Materials and methods: The delivery used a 6 MV TrueBeam linear accelerator (Varian Medical Systems, Palo Alto, CA) with adjustable meterset rates below 100 MU/minute. A platform was constructed to support the patient 6 cm above the floor (similar to 2 m from the source). A 40 x 40 cm(2) field at isocenter along with a 45 degrees collimator rotation was used to achieve a maximum field width of approximately 113 cm at 2 m. The patient was positioned supine with head turned toward the patient's right side for the anteroposterior beam and prone with the head continuing to turn towards the patient's right side for the posteroanterior beam. A scattering plate with custom organ blocks was placed approximately 20 cm from the patient's skin surface. Output, depth-dose, surface-dose, block transmission, and off-axis measurements were taken using solid water slabs, ion chambers, and film. Results: The TrueBeam provides several options for this treatment geometry to deliver LDR TBI at less than 10 cGy/min by lowering the linear accelerator meterset rate below 100 MU/minute. This allowed for a compromise between dose rate and treatment time to be selected by the radiation oncology team without the use of a beam attenuator, thus improving patient safety. Depth-dose and off-axis measurements confirmed a dose distribution within +/- 5% of the central-axis dose. A scattering plate distance of similar to 20 cm from the patient increases surface dose while allowing easy access to the patient during anesthesia. Conclusions: The method described is useful to pediatric radiation oncologists seeking to deliver LDR TBI to an infant patient. (C) 2016 American Society for Radiation Oncology. Published by Elsevier Inc. All rights reserved.
引用
收藏
页码:190 / 194
页数:5
相关论文
共 50 条
  • [1] HUMAN MARROW CHANGES AFTER TREATMENT WITH LOW-DOSE-RATE TOTAL-BODY IRRADIATION
    GOSWITZ, F
    NELSON, B
    VODOPICK, H
    LUSHBAUGH, C
    JOURNAL OF NUCLEAR MEDICINE, 1971, 12 (06) : 359 - +
  • [2] SENSITIZATION OF LOW-DOSE-RATE IRRADIATION BY NONLETHAL HYPERTHERMIA
    SPIRO, IJ
    MCPHERSON, S
    COOK, JA
    LING, CC
    DEGRAFF, W
    MITCHELL, JB
    RADIATION RESEARCH, 1991, 127 (01) : 111 - 114
  • [3] Derivation of isoeffect dose rate for low-dose-rate brachytherapy and external beam irradiation
    Giap, HB
    Massullo, V
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1999, 45 (05): : 1355 - 1358
  • [4] Continuous Low-Dose-Rate Irradiation Promotes Growth of Silkworms
    Shibamoto, Yuta
    Kamei, Yoshiaki
    Kamei, Koichi
    Tsuchiya, Takahiro
    Aoyama, Natsuto
    DOSE-RESPONSE, 2017, 15 (04):
  • [5] RESIDENTS ESSAY AWARD - LOW-DOSE-RATE TOTAL LYMPHOID IRRADIATION - A NEW METHOD OF RAPID IMMUNOSUPPRESSION
    BLUM, JE
    DESILVA, SM
    DRACHMAN, DB
    ORDER, SE
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1988, 15 (03): : 547 - 552
  • [6] Low-Dose-Rate, Low-Dose Irradiation Delays Neurodegeneration in a Model of Retinitis Pigmentosa
    Otani, Atsushi
    Kojima, Hiroshi
    Guo, Congrong
    Oishi, Akio
    Yoshimura, Nagahisa
    AMERICAN JOURNAL OF PATHOLOGY, 2012, 180 (01): : 328 - 336
  • [7] Low-dose-rate ionizing irradiation for inhibition of secondary cataract formation
    Joussen, AM
    Huppertz, B
    Koch, HR
    Kernert, N
    Camphausen, K
    Schlösser, K
    Foerster, AMH
    Kruse, FE
    Lappas, A
    Kirchhof, B
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2001, 49 (03): : 817 - 825
  • [8] Low Dose Rate Pediatric Total Body Irradiation (TBI) Using TrueBeam
    Knutson, N.
    Yaddanapudi, S.
    Li, H.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [9] Overview of radiosensitivity of human tumor cells to low-dose-rate irradiation
    Williams, Jerry R.
    Zhang, Yonggang
    Zhou, Haoming
    Gridley, Daila S.
    Koch, Cameron J.
    Slater, James M.
    Little, John B.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 72 (03): : 909 - 917
  • [10] LOW-DOSE-RATE IRRADIATION IN THE TREATMENT OF HAIRY-CELL LEUKEMIA
    WEITBERG, AB
    DOSORETZ, DE
    SOUTHERN MEDICAL JOURNAL, 1983, 76 (03) : 412 - 414