An experimental and numerical analysis of the thermal performance of double-layer Trombe walls

被引:3
|
作者
Ma, Qingsong [1 ,2 ]
Wang, Xin [2 ]
Chen, Xiaofei [2 ]
Fukuda, Hiroatsu [3 ]
Gao, Weijun [1 ,3 ]
Wei, Xindong [4 ]
机构
[1] Qingdao Univ Technol, iSMART, Qingdao 266033, Peoples R China
[2] Qingdao Univ Technol, Coll Architecture & Urban Planning, Qingdao, Peoples R China
[3] Univ Kitakyushu, Dept Architecture, Kitakyushu, Fukuoka, Japan
[4] Jilin Jianzhu Univ, Sch Environm & Municipal Engn, Changchun, Peoples R China
关键词
Trombe walls; ventilation; energy performance; THERB for HAM; heat utilization; SYSTEMS;
D O I
10.1080/15567036.2021.1939463
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this paper, we propose a new intelligent temperature-controlled ventilated double-layer Trombe wall system for cold climate zones. This system consists of an insulation layer, an inner air channel, a massive wall, an outer air channel and a glazing plate. By changing the ventilated condition of inner and outer air layers, this system further contains three types of Trombe wall structures: inner ventilated (type 1), double ventilated (type 2) and outer ventilated (type 3). This system can automatically control the heat convection between rooms and Trombe walls, according to changes of air channel temperature that is affected by the local weather condition. Thereby, this system can avoid the problem of indoor heat loss at night and indoor overheating during the day. The main objectives of this paper are: 1) to compare the energy consumption of different types with the same thickness of inner and outer air layers; 2) to compare the thermal energy performance of the same type with different thickness of inner and outer air layers; and 3) to optimize the thickness of the inner and outer air layers of the three types of Trombe wall. Long-term experiments were conducted to investigate the heating potential of ventilated Trombe walls in Qingdao (cold climate zone), China. The thermal energy efficiency of three types of Trombe walls was compared and calculated using THERB for HAM software. The measured results demonstrated that the room temperature is always lower than the outer air channel temperature of the Trombe wall, and the heat of the Trombe wall is not fully utilized. Type 2 presents the best energy efficiency, followed by type 3 and type 1. For all types, when the outer air channel depth is greater than the inner air channel depth, the energy efficiency is improved. Affected by dry-bulb temperature and global horizontal irradiation, the monthly heating load of three types of Trombe walls in ascending order are April, November, March, February, December and January. Compared with a house without a ventilated Trombe wall, the heating efficiency of type 2, type 3 and type 1 is 32.6%, 30.5%, and 23.8%, respectively.
引用
收藏
页数:16
相关论文
共 50 条
  • [1] Thermal performance of precast concrete sandwich walls with a double-layer insulation system
    Li, Guochang
    Li, Xiao
    Fang, Chen
    Liu, Runze
    CONSTRUCTION AND BUILDING MATERIALS, 2025, 472
  • [2] Numerical and experimental analysis of building walls thermal performance
    Al Fakhoury, Joelle
    Sassine, Emilio
    Cherif, Yassine
    Dgheim, Joseph
    Antczak, Emmanuel
    JOURNAL OF BUILDING PHYSICS, 2024, 48 (01) : 5 - 30
  • [3] Experimental and Numerical Analysis for Eccentricity Solution in Double-Layer Space Truss
    Vital, Welington
    Silva, Ramon
    Bezerra, Luciano M.
    Oliveira, Cynthia M.
    Freitas, Cleirton A. S.
    Bonilla, Jorge
    BUILDINGS, 2024, 14 (03)
  • [4] Thermal performance and ventilation analysis of a zigzag Trombe wall: Full numerical and experimental investigations
    Zhang, Hong-Liang
    Li, Bin
    Shi, Dun-Ke
    Zhao, Fu-Yun
    ENERGY AND BUILDINGS, 2024, 306
  • [5] Numerical study on thermal performance of a building design integrating two passive Trombe walls
    Ben Romdhane, Sahar
    Amamou, Amani
    Mahjoub, Hammouda
    Said, Nejla Mahjoub
    Jemni, Abdelmajid
    Younsi, Zohir
    ADVANCES IN BUILDING ENERGY RESEARCH, 2023, 17 (06) : 679 - 709
  • [6] Experimental and numerical performance analysis of a TC-Trombe wall
    Yu, Bendong
    He, Wei
    Li, Niansi
    Wang, Liping
    Cai, Jingyong
    Chen, Hongbing
    Ji, Jie
    Xu, Gang
    APPLIED ENERGY, 2017, 206 : 70 - 82
  • [7] Thermal performance study of double-layer microchannel with bifurcation
    Srivastava, Pankaj
    Patel, Ruchitkumar Ishwarlal
    Dewan, Anupam
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2020, 17
  • [8] Thermal performance analysis on a volumetric solar receiver with double-layer ceramic foam
    Chen, Xue
    Xia, Xin-Lin
    Meng, Xian-Long
    Dong, Xian-Hong
    ENERGY CONVERSION AND MANAGEMENT, 2015, 97 : 282 - 289
  • [9] Seismic collapse assessment of double-layer barrel vault roofs with double-layer vertical walls
    Kheirollahi, Mohammad
    Abedi, Karim
    Chenaghlou, Mohammad Reza
    ADVANCES IN STRUCTURAL ENGINEERING, 2019, 22 (13) : 2837 - 2852
  • [10] Experimental and simulation study of the effect of temperature and air supply on energy performance of a temperature-controlled ventilated double-layer Trombe wall
    Ma, Qingsong
    Dong, Xin
    Wei, Xindong
    Xiao, Yuling
    Ma, Hao
    SOLAR ENERGY, 2024, 282