Cerebral MR venography in children: Comparison of 2D time-of-flight and gadolinium-enhanced 3D gradient-echo techniques

被引:36
|
作者
Rollins, N
Ison, C
Reyes, T
Chia, J
机构
[1] Childrens Med Ctr, Dept Radiol, Dallas, TX 75235 USA
[2] Univ Texas, SW Med Ctr, Dallas, TX 75235 USA
[3] Philips Med Syst, Best, Netherlands
关键词
D O I
10.1148/radiol.2353041427
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To prospectively compare two-dimensional (2D) time-of-flight cerebral magnetic resonance (MR) venography with gadolinium-enhanced three-dimensional (3D) gradient-echo cerebral MR venography in children. MATERIALS AND METHODS: This investigation had investigational review board approval and was Health Insurance Portability and Accountability Act compliant; parental informed consent was obtained. Thirty-seven patients (20 boys, 17 girls) who ranged in age from 4 days to 15 years underwent 2D and 3D MR venography. Two pediatric neuroradiologists compared the visibility of the superior sagittal, straight, transverse, and sigmoid sinuses and the internal jugular veins on images obtained with the two sequences. RESULTS: In 17 (46%) of the 37 patients, the sequences were equivalent in terms of their depiction of venous anatomy. In 19 (51%) of the 37 patients, 3D MR venography was superior to 2D MR venography. Suboptimal enhancement of veins occurred in one (3%) patient at 3D MR venography. Venous anomalies suggested at 2D MR venography but not present at 3D MR venography included flow gaps in the nondominant transverse sinuses of four patients, unilateral transverse sinus atresia in eight, and a narrowed superior sagittal sinus in two. Two-dimensional MR venography results failed to reveal a persistent falcine sinus associated with straight sinus atresia in one patient and suggested transverse sinus thrombosis in two patients in whom 3D MR venography results were normal. Additionally, the extent of dural thrombosis was overestimated at 2D MR venography in one patient. As compared with 3D MR venography, 2D MR venography failed to reveal sigmoid sinus stenosis in one patient and poorly depicted posterior fossa dural sinus anatomy in two patients with dural arteriovenous fistula. CONCLUSION: Three-dimensional MR venography is often superior to 2D MR venography in the delineation of major cerebral venous structures in children. Most of the artifactual loss of vascular signal seen with the use of 2D MR venography occurred in nondominant transverse sinuses. (c) RSNA 2005
引用
收藏
页码:1011 / 1017
页数:7
相关论文
共 50 条
  • [1] COMPARISON OF GADOLINIUM-ENHANCED FAST 3D TIME-OF-FLIGHT WITH UNENHANCED 3D AND 2D TIME-OF-FLIGHT MR-ANGIOGRAPHY OF THE BRACHIOCEPHALIC ARTERIES
    HOLLAND, GA
    CARPENTER, JP
    HURST, RW
    SLOSMAN, F
    GOLDBERG, HI
    RADIOLOGY, 1995, 197 : 236 - 236
  • [2] CONTRAST ENHANCEMENT OF NORMAL MENINGES ON GADOLINIUM-ENHANCED 3D GRADIENT-ECHO MR IMAGING
    FARN, JW
    MIROWITZ, SA
    RADIOLOGY, 1992, 185 : 298 - 298
  • [3] MR venography: True FISP sequence versus Gadolinium-enhanced 3d T1-weighted gradient-echo sequence
    Pedrosa, I
    Yu, J
    Mahallati, H
    Bryer, HP
    Morrin, MM
    Rofsky, NM
    RADIOLOGY, 2002, 225 : 359 - 360
  • [4] Gadolinium-enhanced 3D time-of-flight MR angiography - Experimental and clinical evaluation
    Yano, T
    Kodama, T
    Suzuki, Y
    Watanabe, K
    ACTA RADIOLOGICA, 1997, 38 (01) : 47 - 54
  • [5] Suspected pancreatic cancer: Evaluation by dynamic gadolinium-enhanced 3D gradient-echo
    Birchard, KR
    Semelka, RC
    Hyslop, WB
    Brown, A
    Armao, D
    Firat, Z
    Vaidean, G
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (03) : 700 - 703
  • [6] Hepatic MR imaging: comparison of 2D and 3D gradient echo techniques
    M.-J. Kim
    D. G. Mitchell
    K. Ito
    P. N. Kim
    Abdominal Imaging, 2001, 26 : 269 - 276
  • [7] Hepatic MR imaging: comparison of 2D and 3D gradient echo techniques
    Kim, MJ
    Mitchell, DG
    Ito, K
    Kim, PN
    ABDOMINAL IMAGING, 2001, 26 (03): : 269 - 276
  • [8] Pulmonary MR angiography: A comparison of 2D and 3D time-of-flight
    Isoda, H., 1600, Lippincott Williams and Wilkins (18):
  • [9] PULMONARY MR-ANGIOGRAPHY - A COMPARISON OF 2D AND 3D TIME-OF-FLIGHT
    ISODA, H
    MASUI, T
    HASEGAWA, S
    SHIRAKAWA, T
    OHTA, A
    TAKAHASHI, M
    KANEKO, M
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1994, 18 (03) : 402 - 407
  • [10] CHEST MR ANGIOGRAPHY WITH FAST GRADIENT-ECHO SEQUENCES - COMPARISON OF UNENHANCED AND GADOLINIUM-ENHANCED FLASH 2D IMAGES OBTAINED WITH THE ULTRAFAST FLASH TECHNIQUE
    BETSCH, B
    SCHAD, L
    KNOPP, MV
    GAMROTH, A
    HESS, T
    VANKAICK, G
    RADIOLOGY, 1992, 185 : 272 - 272