Fault Ride Through Evaluation of a 1000MW Nuclear Power Plant

被引:0
|
作者
Kopsidas, Konstantinos [1 ]
Elshahed, Mostafa [1 ,2 ]
Preece, Robin [1 ]
Rioual, Michel [3 ]
Duffeau, Francois [3 ]
Marcelles, Ignacio [4 ]
Geissler, Waldemar [5 ]
机构
[1] Univ Manchester, Sch Elect & Elect Engn, Manchester, Lancs, England
[2] Cairo Univ, Giza, Egypt
[3] Elect De France, EDF Lab, Dept THEMIS, Power Syst Components Technol & Modelling, Saclay, France
[4] Tecnatom, Madrid, Spain
[5] AREVA GmbH, Erlangen, Germany
来源
2018 IEEE POWER & ENERGY SOCIETY GENERAL MEETING (PESGM) | 2018年
关键词
Network Grid Codes; Nuclear Power Plants; Over-voltage; Over-frequency; Stability; Turbo-generators;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Modern grid codes attempt to unify the existing standards developed by various national and international organizations, implemented from different utilities and generator manufacturers. This evolution of new grid code practices is associated with increasing interoperability of different power systems across borders. This paper compares existing regional network codes for requirements for grid connection applicable to all generators regarding their compliance with the newly formulated code by the European network of transmission system operators for electricity (ENTSO-E). Furthermore, it studies the impact of the unified ENSTO-E codes on the fault-ride-through capability of nuclear power plants (NPP) under extended operating voltage and frequency ranges. The analysis is performed on the typical 1000MW NPP under different voltage and frequency critical ranges and shows that extending the voltage fluctuation below 0.9 pu could affect NPP reliability.
引用
收藏
页数:5
相关论文
共 50 条
  • [1] HELIUM TURBINE FOR A 1000 MW NUCLEAR-POWER PLANT
    BAMMERT, K
    FINCKH, HH
    TRABLER, MO
    KERNTECHNIK, 1974, 16 (03) : 108 - 114
  • [2] Deactivation of commercial SCR catalyst used in 1000MW coal-fired power plant
    Fang, Tuo-Tuo
    Gao, Er-Hao
    Wang, Liang
    Xu, Nan
    Wang, Xiao-Xiang
    He, Yi
    Pan, Hua
    Shi, Yao
    Zhongguo Huanjing Kexue/China Environmental Science, 2019, 39 (02): : 583 - 590
  • [3] 1987 RESULTS OF GERMAN NUCLEAR-POWER PLANT-OPERATION .2. NUCLEAR GENERATING-UNITS OF LESS THAN 1000MW
    不详
    ATOMWIRTSCHAFT-ATOMTECHNIK, 1988, 33 (06): : 302 - 315
  • [4] Thermal Diagram of the Turbine Unit of a 1000 MW Nuclear Power Plant.
    Bachilo, L.L.
    Terent'ev, I.K.
    Grinman, M.I.
    Piskarev, A.A.
    Kruglikov, P.A.
    Teploenergetika, 1982, (04): : 24 - 27
  • [5] Low-order Active Disturbance Rejection Control on Furnace Pressure of 1000MW Power Plant
    Zhang, Yuqiong
    Xue, Yali
    Yang, Hongbo
    Li, Donghai
    Sun, Li
    Niu, Haiming
    Huang, Huanpao
    PROCEEDINGS OF THE 36TH CHINESE CONTROL CONFERENCE (CCC 2017), 2017, : 4453 - 4458
  • [6] Coordinated Control for an Offshore Wind Power Plant to Provide Fault Ride Through Capability
    Araguees Penalba, Monica
    Gomis-Bellmunt, Oriol
    Martins, Marcia
    IEEE TRANSACTIONS ON SUSTAINABLE ENERGY, 2014, 5 (04) : 1253 - 1261
  • [7] Thermal power plant steam turbines with 1000 MW power
    Salamov, A.A.
    Troyanovskij, B.M.
    Teploenergetika, 1997, (07): : 70 - 76
  • [8] Seismic analysis for SEC drum-shaped filter of 1000 MW nuclear power plant
    Fu, Qiang
    Yuan, Shou-Qi
    Zhu, Rong-Sheng
    Ou, Ming-Xiong
    Yang, Ai-Ling
    Hedongli Gongcheng/Nuclear Power Engineering, 2010, 31 (06): : 10 - 14
  • [9] POSSIBILITY FOR DISTANT HEAT-SUPPLY BY 1000 MW NUCLEAR-POWER PLANT UNITS
    CZINKOCZKY, B
    ENERGIA ES ATOMTECHNIKA, 1988, 41 (03): : 122 - 126
  • [10] CALCULATION OF AXIAL THERMAL EXPANSION FOR A 1000MW NUCLEAR STEAM TURBINE HIP CASING
    Mei, Ziyue
    Zhang, Hengliang
    Xie, Danmei
    Guo, Yanan
    Hou, Xiuqun
    Xiong, Yangheng
    PROCEEDINGS OF THE ASME PRESSURE VESSELS AND PIPING CONFERENCE, 2017, VOL 6A, 2017,