Cross calibration of GF-4 visible and near-infrared sensor with CE-3 VNIS sensor based on lunar

被引:2
|
作者
Tan, Wei [1 ,2 ]
Qi, Wenwen [1 ,2 ]
Wu, Yunzhao [3 ]
He, Hongyan [1 ,2 ]
Cao, Shixiang [1 ,2 ]
机构
[1] Beijing Inst Space Mech & Elect, Satellite Tech Supporting Team, Youyi Rd 104, Beijing 100094, Peoples R China
[2] Beijing Key Lab Opt Remote Sensing Technol, Satellite Calibrat Team, Youyi Rd 104, Beijing 100094, Peoples R China
[3] Chinese Acad Sci, Purple Mt Observ, Planet Spectrum Grp, Yuanhua Rd 8, Nanjing 210034, Peoples R China
来源
OPTIK | 2020年 / 210卷
基金
中国国家自然科学基金;
关键词
Remote sensing; Lunar observation; Cross calibration; Validation; IN-FLIGHT CALIBRATION; REFLECTANCE;
D O I
10.1016/j.ijleo.2020.164478
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
In space-borne remote sensing, the accuracy of radiometric calibration is a key issue for image quality and further data applications. According to the relationship between GF-4 visible and near-infrared (VNIR) sensor and CE-3 VNIS sensor, an applicable cross radiometric calibration method is proposed here based on the observation data of lunar. The cross calibration generates a set of radiometric calibration coefficients for GF-4 VNIR sensor. Two validation experiments are implemented to verify the authenticity and accuracy of cross calibration coefficients: the proposed approach shows a high consistency than previous coefficients by comparing the retrieved reflectance of three calibration sites on lunar, and gets the accuracy of 5.34 %, 3.42 %, 3.49 % and 5.96 % with blue, green, red and near infrared bands of GF-4 by ground-based experiments.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Radiometric model of lunar based on GF-4 visible and near-infrared sensor
    Tan, Wei
    Qi, Wenwen
    Wu, Yunzhao
    He, Hongyan
    Chen, Xuan
    OPTOELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY VII, 2020, 11550
  • [2] Calibration of Visible and Near-infrared Imaging Spectrometer (VNIS) on lunar surface
    Xu Rui
    Lv Gang
    Ma Yan-hua
    Wang Jian-yu
    MULTISPECTRAL, HYPERSPECTRAL, AND ULTRASPECTRAL REMOTE SENSING TECHNOLOGY, TECHNIQUES AND APPLICATIONS V, 2014, 9263
  • [3] Visible and Near-Infrared Imaging Spectrometer (VNIS) For In Situ Lunar Surface Measurements
    He, Zhiping
    Xu, Rui
    Li, Chunlai
    Lv, Gang
    Yuan, Liyin
    Wang, Binyong
    Shu, Rong
    Wang, Jianyu
    SENSORS, SYSTEMS, AND NEXT-GENERATION SATELLITES XIX, 2015, 9639
  • [4] In-Flight Calibration of Visible and Near-Infrared Imaging Spectrometer (VNIS) Onboard Chang'E-4 Unmanned Lunar Rover
    Xu, Rui
    Lin, Honglei
    Wang, Meizhu
    Liu, Bin
    Yan, Wei
    Liu, Chengyu
    Lv, Gang
    Yuan, Liyin
    Li, Chunlai
    Wang, Rong
    Liu, Dawei
    Yang, Yazhou
    Jiang, Ziqing
    Yang, Benyong
    Wang, Lei
    Xu, Jiafei
    Li, Jinning
    He, Zhiping
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2022, 60
  • [5] Radiometric Cross-Calibration of GF-4 PMS Sensor Based on Assimilation of Landsat-8 OLI Images
    Chen, Yepei
    Sun, Kaimin
    Li, Deren
    Bai, Ting
    Huang, Chengquan
    REMOTE SENSING, 2017, 9 (08): : 1 - 19
  • [6] Visible and Near-infrared Imaging Spectrometer (VNIS) for Chang'E-3
    He, Zhiping
    Wang, Binyong
    Lv, Gang
    Li, Chunlai
    Yuan, Liyin
    Xu, Rui
    Chen, Kai
    Wang, Jianyu
    MULTISPECTRAL, HYPERSPECTRAL, AND ULTRASPECTRAL REMOTE SENSING TECHNOLOGY, TECHNIQUES AND APPLICATIONS V, 2014, 9263
  • [7] Radiometric cross-calibration of GF-4 satellite PMS sensor considering the characteristics of multiple integration times
    Han J.
    Tao Z.
    Xie Y.
    Liu Q.
    Shi H.
    Cehui Xuebao/Acta Geodaetica et Cartographica Sinica, 2020, 49 (10): : 1311 - 1320
  • [8] Radiometric Cross-Calibration of GF-4/IRS Based on MODIS Measurements
    Zhou, Xiang
    Feng, Duo
    Xie, Yong
    Tao, Zui
    Lv, Tingting
    Wang, Jin
    IEEE JOURNAL OF SELECTED TOPICS IN APPLIED EARTH OBSERVATIONS AND REMOTE SENSING, 2021, 14 : 6807 - 6814
  • [9] PYRAMIR: Calibration and operation of a pyramid near-infrared wavefront sensor
    Peter, D.
    Feldt, M.
    Dorner, B.
    Henning, T.
    Hippler, S.
    Aceituno, J.
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF THE PACIFIC, 2008, 120 (870) : 872 - 886
  • [10] Radiometric Cross-Calibration of GF-4/PMS Based on Radiometric Block Adjustment
    Han, Jie
    Tao, Zui
    Xie, Yong
    Liu, Qiyue
    Huang, Youju
    IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2021, 59 (06): : 4522 - 4534