Lead-I ECG for detecting atrial fibrillation in patients attending primary care with an irregular pulse using single-time point testing: A systematic review and economic evaluation

被引:16
|
作者
Duarte, Rui [1 ]
Stainthorpe, Angela [1 ,2 ]
Mahon, James [3 ]
Greenhalgh, Janette [1 ]
Richardson, Marty [1 ]
Nevitt, Sarah [1 ]
Kotas, Eleanor [1 ,4 ]
Boland, Angela [1 ]
Thom, Howard [5 ]
Marshall, Tom [6 ]
Hall, Mark [7 ]
Takwoingi, Yemisi [6 ,8 ,9 ]
机构
[1] Univ Liverpool, Liverpool Reviews & Implementat Grp, Liverpool, Merseyside, England
[2] Hlth Econ & Outcomes Res Ltd, Cardiff, Wales
[3] Coldingham Analyt Serv, Duns, Berwick, Scotland
[4] Univ York, York Hlth Econ Consortium, York, N Yorkshire, England
[5] Univ Bristol, Bristol Med Sch Populat Hlth Sci, Bristol, Avon, England
[6] Univ Birmingham, Inst Appl Hlth Res, Birmingham, W Midlands, England
[7] Liverpool Heart & Chest Hosp, Liverpool, Merseyside, England
[8] Univ Hosp Birmingham NHS Fdn Trust, NIHR Birmingham Biomed Res Ctr, Birmingham, W Midlands, England
[9] Univ Birmingham, Birmingham, W Midlands, England
来源
PLOS ONE | 2019年 / 14卷 / 12期
基金
美国国家卫生研究院; 英国医学研究理事会;
关键词
HAND-HELD; COST-EFFECTIVENESS; IPHONE ECG; GENERAL-PRACTICE; ACCURACY; DEVICE; METAANALYSIS; FEASIBILITY; NURSES;
D O I
10.1371/journal.pone.0226671
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Background Atrial fibrillation (AF) is the most common type of cardiac arrhythmia and is associated with increased risk of stroke and congestive heart failure. Lead-I electrocardiogram (ECG) devices are handheld instruments that can detect AF at a single-time point. Purpose To assess the diagnostic test accuracy, clinical impact and cost effectiveness of single-time point lead-I ECG devices compared with manual pulse palpation (MPP) followed by a 12-lead ECG for the detection of AF in symptomatic primary care patients with an irregular pulse. Methods Electronic databases (MEDLINE, MEDLINE Epub Ahead of Print and MEDLINE In-Process, EMBASE, PubMed and Cochrane Databases of Systematic Reviews, Cochrane Central Database of Controlled Trials, Database of Abstracts of Reviews of Effects, Health Technology Assessment Database) were searched to March 2018. Two reviewers screened the search results, extracted data and assessed study quality. Summary estimates of diagnostic accuracy were calculated using bivariate models. Cost-effectiveness was evaluated using an economic model consisting of a decision tree and two cohort Markov models. Results Diagnostic accuracy The diagnostic accuracy (13 publications reporting on nine studies) and clinical impact (24 publications reporting on 19 studies) results are derived from an asymptomatic population (used as a proxy for people with signs or symptoms of AF). The summary sensitivity of lead-I ECG devices was 93.9% (95% confidence interval [CI]: 86.2% to 97.4%) and summary specificity was 96.5% (95% CI: 90.4% to 98.8%). Cost effectiveness The de novo economic model yielded incremental cost effectiveness ratios (ICERs) per quality adjusted life year (QALY) gained. The results of the pairwise analysis show that all lead-I ECG devices generate ICERs per QALY gained below the 20,000- pound 30,000 pound threshold. Kardia Mobile is the most cost effective option in a full incremental analysis. Lead-I ECG tests may identify more AF cases than the standard diagnostic pathway. This comes at a higher cost but with greater patient benefit in terms of mortality and quality of life. Limitations No published data evaluating the diagnostic accuracy, clinical impact or cost effectiveness of lead-I ECG devices for the target population are available. Conclusions The use of single-time point lead-I ECG devices in primary care for the detection of AF in people with signs or symptoms of AF and an irregular pulse appears to be a cost effective use of NHS resources compared with MPP followed by a 12-lead ECG, given the assumptions used in the base case model. Registration The protocol for this review is registered on PROSPERO as CRD42018090375.
引用
收藏
页数:17
相关论文
共 2 条
  • [1] Lead-I ECG for detecting atrial fibrillation in patients with an irregular pulse using single time point testing: a systematic review and economic evaluation
    Duarte, Rui
    Stainthorpe, Angela
    Greenhalgh, Janette
    Richardson, Marty
    Nevitt, Sarah
    Mahon, James
    Kotas, Eleanor
    Boland, Angela
    Thom, Howard
    Marshall, Tom
    Hall, Mark
    Takwoingi, Yemisi
    HEALTH TECHNOLOGY ASSESSMENT, 2020, 24 (03) : 1 - +
  • [2] Clinical Factors Associated with Atrial Fibrillation Detection on Single-Time Point Screening Using a Hand-Held Single-Lead ECG Device
    Boriani, Giuseppe
    Palmisano, Pietro
    Malavasi, Vincenzo Livio
    Fantecchi, Elisa
    Vitolo, Marco
    Bonini, Niccolo'
    Imberti, Jacopo F.
    Valenti, Anna Chiara
    Schnabel, Renate B.
    Freedman, Ben
    JOURNAL OF CLINICAL MEDICINE, 2021, 10 (04) : 1 - 13