The effect of heart rate on coronary plaque measurements in 320-row coronary CT angiography

被引:7
|
作者
Kidoh, Masafumi [1 ]
Utsunomiya, Daisuke [1 ]
Funama, Yoshinori [2 ]
Sakabe, Daisuke [1 ]
Oda, Seitaro [1 ]
Nakaura, Takeshi [1 ]
Yuki, Hideaki [1 ]
Nagayama, Yasunori [1 ]
Hirata, Kenichiro [1 ]
Iyama, Yuji [1 ]
Namimoto, Tomohiro [1 ]
Yamashita, Yasuyuki [1 ]
机构
[1] Kumamoto Univ, Dept Diagnost Radiol, Fac Life Sci, 1-1-1 Honjo, Kumamoto 8608556, Japan
[2] Kumamoto Univ, Dept Med Phys, Fac Life Sci, 1-1-1 Honjo, Kumamoto 8608556, Japan
来源
基金
日本学术振兴会;
关键词
Coronary computed tomography angiography; Coronary artery disease; Coronary artery plaque; Non-calcified plaque; Model-based iterative reconstruction; COMPUTED TOMOGRAPHIC ATTENUATION; ATHEROSCLEROTIC PLAQUES; INTRACORONARY ATTENUATION; IN-VITRO; ALGORITHM; THICKNESS; ACCURACY; THERAPY; DENSITY; IMPACT;
D O I
10.1007/s10554-018-1415-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Repeatability of quantitative assessment of atherosclerotic plaques is important for the accurate detection of high-risk plaques in coronary CT angiography (CTA). We assessed the effect of heart rate (HR) on plaque CT number using a coronary artery model and a cardiac phantom capable of simulating cardiac motion. The coronary artery model with luminal stenosis on a cardiac phantom was imaged with a simulated HR of 0, 50, 60, and 70 beats per minute using a 320-row CT scanner. We reconstructed CT images for cardiac diastolic phases (for 75% R-R interval) using filtered back projection (FBP), hybrid iterative reconstruction (AIDR3D), and model-based iterative reconstruction (FIRST). Two observers measured plaque attenuation in the lesion with 75% stenosis. The coefficient of determination (R-2) was obtained to evaluate interobserver agreement. At HR 70, FIRST improved the correlation between two observers compared with FBP and AIDR3D (FIRST: R-2=0.68, p<0.05; FBP: R-2=0.29, p=0.31; AIDR3D: R-2=0.22, p=0.18). These R-2 at HR 70 were lower compared with at HR 50 (FIRST: R-2=0.92, p<0.05; FBP: R-2=0.83, p<0.05; AIDR3D: R-2=0.87, p<0.05) and HR 0 (FIRST: R-2=0.97, p<0.05; FBP: R-2=0.89, p<0.05; AIDR3D: R-2=0.95, p<0.05). Higher HR affected plaque measurement repeatability in coronary CTA. FIRST may improve plaque measurement repeatability at the higher HR compared with FBP and AIDR3D.
引用
收藏
页码:1977 / 1985
页数:9
相关论文
共 50 条
  • [1] The effect of heart rate on coronary plaque measurements in 320-row coronary CT angiography
    Masafumi Kidoh
    Daisuke Utsunomiya
    Yoshinori Funama
    Daisuke Sakabe
    Seitaro Oda
    Takeshi Nakaura
    Hideaki Yuki
    Yasunori Nagayama
    Kenichiro Hirata
    Yuji Iyama
    Tomohiro Namimoto
    Yasuyuki Yamashita
    The International Journal of Cardiovascular Imaging, 2018, 34 : 1977 - 1985
  • [2] Comparison of position, morphology and calcification of Coronary Plaque with 320-row dynamic volume CT (DVCT) and coronary angiography (CAG)
    Li, Xiaoyan
    Zhang, Guoming
    Zhang, Hongming
    PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2014, 30 (04) : 824 - 829
  • [3] The feasibility of halfcycle reconstruction in high heart rates in coronary CT angiography using 320-row CT
    Tomizawa, Nobuo
    Yamamoto, Kodai
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (04): : 907 - 911
  • [4] The feasibility of halfcycle reconstruction in high heart rates in coronary CT angiography using 320-row CT
    Nobuo Tomizawa
    Kodai Yamamoto
    Masaaki Akahane
    Rumiko Torigoe
    Shigeru Kiryu
    Kuni Ohtomo
    The International Journal of Cardiovascular Imaging, 2013, 29 : 907 - 911
  • [5] Diagnostic accuracy of 320-row coronary CT angiography in the assessment of coronary in-stent restenosis
    Kishi, S.
    Tanabe, K.
    Yachi, S.
    Otsuka, T.
    Nakajima, Y.
    Taniwaki, M.
    Tanimoto, S.
    Aoki, J.
    Nakajima, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2011, 32 : 524 - 524
  • [6] Evaluation of the Effect of Intracoronary Attenuation on Coronary Plaque Measurements Using a Dual-phase Coronary CT Angiography Technique on a 320-row CT Scanner-In Vivo Validation Study
    Kidoh, Masafumi
    Utsunomiya, Daisuke
    Oda, Seitaro
    Funama, Yoshinori
    Nakaura, Takeshi
    Yuki, Hideaki
    Hirata, Kenichiro
    Namimoto, Tomohiro
    Yamashita, Yasuyuki
    ACADEMIC RADIOLOGY, 2016, 23 (03) : 315 - 320
  • [7] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Tomizawa, Nobuo
    Kanno, Shigeaki
    Maeda, Eriko
    Akahane, Masaaki
    Torigoe, Rumiko
    Ohtomo, Kuni
    JAPANESE JOURNAL OF RADIOLOGY, 2014, 32 (07) : 391 - 396
  • [8] Risk factors associated with total coronary plaque burden: assessment by 320-row ct
    Asami, M.
    Tanabe, K.
    Hashimoto, T.
    Nakashima, M.
    Yahagi, K.
    Nakajima, Y.
    Tanimoto, S.
    Aoki, J.
    Nakajima, H.
    Hara, K.
    EUROPEAN HEART JOURNAL, 2013, 34 : 975 - 975
  • [9] Minimizing the acquisition phase in coronary CT angiography using the second generation 320-row CT
    Nobuo Tomizawa
    Shigeaki Kanno
    Eriko Maeda
    Masaaki Akahane
    Rumiko Torigoe
    Kuni Ohtomo
    Japanese Journal of Radiology, 2014, 32 : 391 - 396
  • [10] Effect of saline flush on enhancement of proximal and distal segments using 320-row coronary CT angiography
    Tomizawa, Nobuo
    Suzuki, Fumio
    Akahane, Masaaki
    Torigoe, Rumiko
    Kiryu, Shigeru
    Ohtomo, Kuni
    EUROPEAN JOURNAL OF RADIOLOGY, 2013, 82 (08) : 1255 - 1259