P-wave dispersion between transcatheter and surgical closure of secundum-type atrial septal defect in childhood

被引:15
|
作者
Baspinar, Osman [1 ]
Sucu, Murat [2 ]
Koruk, Senem [3 ]
Kervancioglu, Mehmet
Ustunsoy, Hasim [4 ]
Deniz, Hayati [4 ]
Kilinc, Metin
机构
[1] Gaziantep Univ, Dept Pediat Cardiol, Fac Med, Clin Pediat Cardiol, TR-27310 Gaziantep, Turkey
[2] Gaziantep Univ, Clin Cardiol, Fac Med, TR-27310 Gaziantep, Turkey
[3] Gaziantep Univ, Anesthesiol Clin, Fac Med, TR-27310 Gaziantep, Turkey
[4] Gaziantep Univ, Clin Cardiothorac Surg, Fac Med, TR-27310 Gaziantep, Turkey
关键词
P-wave dispersion; transcatheter closure; surgical closure; Amplatzer device; childhood; ADULT PATIENTS; FIBRILLATION; DURATION; CHILDREN; SURGERY; REPAIR;
D O I
10.1017/S1047951110001307
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Patients with atrial septal defect have an increased risk for atrial fibrillation. Increased P-wave dispersion predicts the development of atrial fibrillation. The aim of this study was to determine difference in P dispersion between transcatheter closure with Amplatzer septal occluder and surgical closure in childhood. A total of 68 children (the mean age was 7.2 plus or minus 3.3 years; the mean secundum atrial septal defects diameter was 17.3 plus or minus 5.4 millimetres) were evaluated in this study. Transcatheter closure was attempted in 41 children with secundum atrial septal defects, and the defect in 27 patients was closed by surgical techniques. P maximum, P minimum and P dispersion were measured by the 12-lead surface electrocardiography. P maximum, P minimum and P dispersion were found to be similar in patients with pre-and post-procedure (98.0 plus or minus 19.3 versus 95.1 plus or minus 23.0 milliseconds; 68.0 plus or minus 20.8 versus 67.6 plus or minus 24.3 milliseconds, 29.9 plus or minus 11.0 versus 27.1 plus or minus 12.1 milliseconds, respectively). There was no statistical significance in the comparison of P dispersion between the two groups. But in the surgical group, P-wave dispersion was decreased more significantly compared with baseline values (p-value equal to 0.03). In conclusion, there is no P dispersion between transcatheter closure with Amplatzer septal occluder and surgical closure of secundum atrial septal defect.
引用
收藏
页码:15 / 18
页数:4
相关论文
共 50 条
  • [1] Longitudinal Evaluation of P-Wave Dispersion and P-Wave Maximum in Children After Transcatheter Device Closure of Secundum Atrial Septal Defect
    Grignani, Robert Teodoro
    Tolentino, Kim Martin
    Rajgor, Dimple Dayaram
    Quek, Swee Chye
    PEDIATRIC CARDIOLOGY, 2015, 36 (05) : 1050 - 1056
  • [2] Longitudinal Evaluation of P-Wave Dispersion and P-Wave Maximum in Children After Transcatheter Device Closure of Secundum Atrial Septal Defect
    Robert Teodoro Grignani
    Kim Martin Tolentino
    Dimple Dayaram Rajgor
    Swee Chye Quek
    Pediatric Cardiology, 2015, 36 : 1050 - 1056
  • [3] P wave dispersion in assessment of dysrhythmia risk in patients with secundum type atrial septal defect and the effect of transcatheter or surgical closure
    Cenk, Muruvvet
    Akalin, Figen
    Saylan, Berna C.
    Ak, Koray
    CARDIOLOGY IN THE YOUNG, 2020, 30 (02) : 263 - 270
  • [4] The effects of surgical repair on P-wave dispersion in children with secundum atrial septal defect
    Yavuz, Taner
    Nisli, Kemal
    Oner, Naci
    Dindar, Aygun
    Aydogan, Umrah
    Omeroglu, Rukiye Eker
    Ertugrul, Turkan
    ADVANCES IN THERAPY, 2008, 25 (08) : 795 - 800
  • [5] The effects of surgical repair on P-wave dispersion in children with secundum atrial septal defect
    Taner Yavuz
    Kemal Nisli
    Naci Oner
    Aygun Dindar
    Umrah Aydogan
    Rukiye Eker Omeroglu
    Turkan Ertugrul
    Advances in Therapy, 2008, 25 : 795 - 800
  • [6] Maximum P-wave duration and P-wave dispersion in adult patients with secundum atrial septal defect: the impact of surgical repair
    Guray, U
    Guray, Y
    Yimaz, MB
    Mecit, B
    Boyaci, AA
    Sasmaz, H
    Korkmaz, S
    Kutuk, E
    EUROPEAN HEART JOURNAL, 2003, 24 : 48 - 48
  • [7] Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders
    Masura, J
    Gavora, P
    Podnar, T
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2005, 45 (04) : 505 - 507
  • [8] Transcatheter closure of secundum-type atrial septal defect with no aortic rim using Amplatzer septal occlude devices and no balloon
    Hengrussamee, Kriengkrai
    Kanaderm, Chanikan
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2016, 68 (18) : B251 - B251
  • [9] Transcatheter closure of secundum atrial septal defect
    Shimpo H.
    Hojo R.
    Ryo M.
    Konuma T.
    Tempaku H.
    General Thoracic and Cardiovascular Surgery, 2013, 61 (11) : 614 - 618
  • [10] Neurodevelopment and Behavior after Transcatheter versus Surgical Closure of Secundum Type Atrial Septal Defect
    Sarrechia, Iemke
    De Wolf, Daniel
    Miatton, Marijke
    Francois, Katrien
    Gewillig, Marc
    Meyns, Bart
    Vingerhoets, Guy