Effect of Salivary Contamination on Microleakage of Resin Composites Placed with a Self-etch Adhesive in Primary Teeth: An In Vitro Study

被引:0
|
作者
Fakhri, Marjan [2 ]
Seraj, Bahman [2 ]
Shahrabi, Mehdi
Motahhary, Pouria [3 ]
Hooshmand, Tabassom [1 ]
机构
[1] Univ Tehran Med Sci, Sch Dent, Res Ctr Sci & Technol Med, Dept Dent Mat, Tehran, Iran
[2] Univ Tehran Med Sci, Sch Dent, Dept Pediat Dent, Tehran, Iran
[3] Univ Tehran Med Sci, Sch Dent, Dept Oral & Maxillofacial Pathol, Tehran, Iran
关键词
SALIVA; CONTAMINATION; MICROLEAKAGE; SELF-ETCHING ADHESIVE; PRIMARY TEETH; MICROTENSILE BOND STRENGTH; DENTIN; SYSTEMS; ENAMEL; TIME;
D O I
暂无
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this study was to investigate in vitro the effect of salivary contamination on the microleakage of resin composite restorations placed with a self-etching adhesive in primary teeth. Methods: Fifty-six extracted primary molars received standardized Class V preparations. The teeth were assigned to 7 groups (n=8): 1-layer and 2-layer application of the self-etching primer (Clearfil SE Bond) with no contamination (groups 1 and 2, respectively); saliva, SE primer, and drying (group 3); SE primer, drying, saliva, and drying (group 4); SE primer, drying, saliva, and rinsing/drying (group 5); SE primer, drying, saliva, drying, SE primer, and drying (group 6); and SE primer, drying, saliva, rinsing/drying, SE primer, and drying (group 7). For all specimens, the bonding agent (SE adhesive) and a composite were applied. After thermocycling and immersing in basic fuchsin, the teeth were sectioned and evaluated under a stereomicroscope. Data were analyzed using Kruskal-Wallis and Mann-Whitney tests. Results: The mean occlusal and gingival microleakage for groups 4 and 5 were significantly higher than that of groups 1 and 2 (P<.04). No statistically significant difference in microleakage among groups 1, 2, 6, and 7 was found (P=.09). The degree of microleakage in the gingival margins was significantly higher than that of occlusal margins (P=.027). Conclusions: The self-etching adhesive was not sensitive to saliva when contamination occurred before primer application. (Pediatr Dent 2009;31:334-9) Received March 2, 2008 vertical bar Last Revision August 19, 2008 vertical bar Revision Accepted August 28, 2008
引用
收藏
页码:334 / 339
页数:6
相关论文
共 50 条
  • [1] A comparison of the resin tag penetration of the total etch and the self-etch dentin bonding systems in the primary teeth: An in vitro study
    Mithiborwala, Sajjad
    Chaugule, Vishwas
    Munshi, A. K.
    Patil, Vishwas
    CONTEMPORARY CLINICAL DENTISTRY, 2012, 3 (02) : 158 - 163
  • [2] In Vitro Comparison of Microleakage of Posterior Resin Composites With and Without Liner Using Two-Step Etch-and-Rinse and Self-etch Dentin Adhesive Systems
    Kasraei, S.
    Azarsina, M.
    Majidi, S.
    OPERATIVE DENTISTRY, 2011, 36 (02) : 213 - 221
  • [3] Effect of Caries of Detecting Dye on Microleakage of Composite Resin Restorations Bonded with Total-etch and Self-etch Adhesive Systems
    Hui, Lim Ern
    Thomas, Manuel S.
    Jathanna, Vinod
    Lewis, Amitha Juanita
    Srikant, N.
    JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH, 2019, 13 (05) : ZC01 - ZC03
  • [4] Microleakage and characteristics of resin-tooth tissues interface of a self-etch and an etch-and-rinse adhesive systems
    Xuan Vinh Tran
    Khanh Quang Tran
    RESTORATIVE DENTISTRY AND ENDODONTICS, 2021, 46 (02):
  • [5] BOND STRENGTH OF SELF-ETCH ADHESIVES WITH PRIMARY AND PERMANENT TEETH DENTIN - IN VITRO STUDY
    Gateva, Natalia
    Dikov, Valentin
    JOURNAL OF IMAB, 2012, 18 (02): : 168 - 173
  • [6] Effect of collagenase and esterase on resin-dentin interface: A comparative study between a total-etch adhesive and a self-etch adhesive
    Jung, Young-Jung
    Hyun, Hong-Keun
    Kim, Young-Jae
    Jang, Ki-Taeg
    AMERICAN JOURNAL OF DENTISTRY, 2009, 22 (05): : 295 - 298
  • [7] Comparative Evaluation of Microleakage of Flowable Composite Resin Using Etch and Rinse, Self-Etch Adhesive Systems, and Self-Adhesive Flowable Composite Resin in Class V Cavities: Confocal Laser Microscopic Study
    Sengar, Ekta Varma
    Mulay, Sanjyot
    Beri, Lotika
    Gupta, Archana
    Almohareb, Thamer
    Binalrimal, Sultan
    Robaian, Ali
    Bahammam, Maha A.
    Bahammam, Hammam Ahmed
    Bahammam, Sarah Ahmed
    Zidane, Bassam
    Albar, Nassreen H.
    Bhandi, Shilpa
    Shrivastava, Deepti
    Srivastava, Kumar Chandan
    Patil, Shankargouda
    MATERIALS, 2022, 15 (14)
  • [8] The effect of saliva contamination on microleakage of an etch-and-rinse and a self-etching adhesive
    Yazici, A. Rueya
    Tuncer, Duygu
    Dayangac, Berrin
    Oeguenaltay, Guel
    Oenen, Alev
    JOURNAL OF ADHESIVE DENTISTRY, 2007, 9 (03): : 305 - 309
  • [9] Microleakage assessment of one- and two-step self-etch adhesive systems with the low shrinkage composites
    Hoseinifar, Razieh
    Kermanshah, Hamid
    JOURNAL OF ORAL HEALTH AND ORAL EPIDEMIOLOGY, 2015, 4 (02): : 71 - 79
  • [10] Effect of smear layer deproteinizing on resin-dentine interface with self-etch adhesive
    Thanatvarakorn, Ornnicha
    Nakajima, Masatoshi
    Prasansuttiporn, Taweesak
    Ichinose, Shizuko
    Foxton, Richard M.
    Tagami, Junji
    JOURNAL OF DENTISTRY, 2014, 42 (03) : 298 - 304