Efficacy and Safety of Ologen Implant Versus Mitomycin C in Primary Trabeculectomy: A Meta-analysis of Randomized Clinical Trials

被引:22
|
作者
Ji, Qingshan [1 ]
Qi, Bing [2 ]
Liu, Lian [2 ]
Guo, Xiaoling [3 ]
Zhong, Jingxiang [2 ]
机构
[1] Anhui Med Univ, Affiliated Anhui Prov Hosp, Dept Ophthalmol, Hefei, Peoples R China
[2] Jinan Univ, Affiliated Hosp 1, Dept Ophthalmol, Guangzhou 510632, Guangdong, Peoples R China
[3] Jinan Univ, Inst Cell Biol, Dept Cell Biol, Guangzhou 510632, Guangdong, Peoples R China
关键词
trabeculectomy; Ologen; mitomycin C; glaucoma; meta-analysis; COLLAGEN MATRIX IMPLANT; INTRAOPERATIVE; 5-FLUOROURACIL; INTRAOCULAR-PRESSURE; GLAUCOMA; SURGERY; HYPOTONY;
D O I
10.1097/IJG.0000000000000147
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose:To assess the efficacy and safety of trabeculectomy with Ologen implant versus trabeculectomy with mitomycin C (MMC) for treatment of glaucoma.Patients and Methods:Medline, EMBASE, Web of Science, Cochrane Central Register of Controlled Trials, and Google Scholar were searched for relevant randomized controlled trials. The outcome measures of efficacy were intraocular pressure and glaucoma medications reductions, and success rate. Safety estimates were measured by relative ratio for complications.Results:A total of 6 studies including 224 participants were included in this meta-analysis. Ologen implant was associated with a numerically lower but nonsignificant percentage reduction in IOP compared with MMC. The pooled absolute IOP decreases from baseline (95% confidence interval) were: 13.28 mm Hg (11.33-15.23 mm Hg) versus 15.8 mm Hg (13.21-18.38 mm Hg) at 1 month; 12.95 mm Hg (11.45-14.44 mm Hg) versus 13.87 mm Hg (11.77-15.97 mm Hg) at 3 months; 11.44 mm Hg (8.77-14.11 mm Hg) versus 13.34 mm Hg (11.48-15.20 mm Hg) at 6 months; 10.05 mm Hg (7.14-12.96 mm Hg) versus 11.59 mm Hg (10.27-12.91 mm Hg) at 12 months; and 12.17 mm Hg (8.88-15.47 mm Hg) versus 10.64 mm Hg (8.15-13.12 mm Hg) at 24 months for Ologen implant versus MMC, respectively. There was no significant difference in the reduction in glaucoma medications, success rate, and incidence of complications.Conclusions:Trabeculectomy with an Ologen implant is comparable to the use of MMC with a similar long-term success rate. However, it does not seem to offer significant advantages of avoiding the potential complications related to MMC.
引用
收藏
页码:e88 / e94
页数:7
相关论文
共 50 条
  • [1] Ologen implant versus mitomycin-C for trabeculectomy A meta-analysis
    Song, De-Sheng
    Qian, Jing
    Chen, Zhi-Jun
    MEDICINE, 2019, 98 (25)
  • [2] Ologen Implant versus Mitomycin C for Trabeculectomy: A Systematic Review and Meta-Analysis
    He, Miao
    Wang, Wei
    Zhang, Xiulan
    Huang, Wenyong
    PLOS ONE, 2014, 9 (01):
  • [3] Efficacy and Safety of Bevacizumab Combined with Mitomycin C or 5-Fluorouracil in Primary Trabeculectomy: A Meta-Analysis of Randomized Clinical Trials
    Chen, Hung-Ju
    Lin, Chin
    Lee, Cho-Hao
    Chen, Yi-Hao
    OPHTHALMIC RESEARCH, 2018, 59 (03) : 155 - 163
  • [4] Subscleral trabeculectomy with Ologen implant versus mitomycin C in primary infantile glaucoma
    Kassem, Rehab R.
    Esmael, Amanne F.
    SAUDI JOURNAL OF OPHTHALMOLOGY, 2024, 38 (04) : 352 - 359
  • [5] Ologen implant versus mitomycin C in combined trabeculectomy and phacoemulsification
    Paul, Chandrima
    Divya, J.
    Kamal, Richa
    Paul, Anujeet
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2022, 70 (04) : 1248 - 1252
  • [6] Prospective Randomized Trial Comparing Mitomycin C Combined with Ologen Implant versus Mitomycin C Alone as Adjuvants in Trabeculectomy
    Sen, Mrittika
    Midha, Neha
    Sidhu, Talvir
    Angmo, Dewang
    Sihota, Ramanjit
    Dada, Tanuj
    OPHTHALMOLOGY GLAUCOMA, 2018, 1 (02): : 88 - 98
  • [7] Mitomycin C versus 5-fluorouracil as an adjunctive treatment for trabeculectomy: a meta-analysis of randomized clinical trials
    De Fendi, Ligia I.
    Arruda, Gustavo V.
    Scott, Ingrid U.
    Paula, Jayter S.
    CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2013, 41 (08): : 798 - 806
  • [8] Trabeculectomy with Ologen matrix implant versus trabeculectomy with mitomycin-C in primary open-angle glaucoma
    Mohsen, Tarek
    JOURNAL OF THE EGYPTIAN OPHTHALMOLOGICAL SOCIETY, 2019, 112 (03) : 104 - 107
  • [9] Comparison of outcomes of trabeculectomy with mitomycin C vs. ologen implant in primary glaucoma
    Senthil, Sirisha
    Rao, Harsha L.
    Babu, Jonnadula G.
    Mandal, Anil K.
    Garudadri, Chandra Sekhar
    INDIAN JOURNAL OF OPHTHALMOLOGY, 2013, 61 (07) : 338 - 342
  • [10] Trabeculectomy with Ologen implant versus mitomycin C in congenital glaucoma secondary to Sturge Weber Syndrome
    Thanaa Helmy Mohamed
    Abdelrahman Gaber Salman
    Riham Fawzy Elshinawy
    International Journal of Ophthalmology, 2018, (02) : 251 - 255