Visual outcome and optical quality of a wavefront-engineered extended depth-of-focus intraocular lens

被引:7
|
作者
Greve, Daria [1 ]
Bertelmann, Eckart [2 ]
Pilger, Daniel [2 ]
von Sonnleithner, Christoph [2 ]
机构
[1] Vivantes Neukolln, Dept Ophthalmol, Berlin, Germany
[2] Charite Med Univ, Dept Ophthalmol, Campus Virchow,Augustenburger Pl 1, D-13353 Berlin, Germany
来源
关键词
PERFORMANCE; IMPLANTATION; ABERRATION;
D O I
10.1097/j.jcrs.0000000000000604
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To evaluate visual performance and optical quality of an extended depth-of-focus intraocular lens (EDoF IOL) compared with a monofocal aspheric IOL. Setting: Department of Ophthalmology, Charit acute accent e-Medical University Berlin, Germany. Design: Prospective case series. Methods: After phacoemulsification, a total of 28 patients (56 eyes) underwent bilateral implantation of either the Mini Well (EDoF IOL) or the Mini 4 (monofocal IOL). Assessments including refraction, distance, intermediate and near visual acuity, defocus curves, contrast sensitivity, glare disability, higher-order aberrations (HOAs), and patient satisfaction were performed at 1 month and 3 months postoperatively. Results: Both study groups comprised 14 patients (28 eyes) each. At 3-month follow-up, the EDoF IOL showed better results in monocular uncorrected intermediate visual acuity (-0.04 vs 0.10 logMAR, P = .000) and in uncorrected near visual acuity (0.13 vs 0.36 logMAR, P = .000), whereas no statistically significant difference was found between groups in monocular uncorrected distance visual acuity (0.04 vs 0.00 logMAR, P = .110). The monocular depth of focus was 0.8 D greater in the Mini Well IOL group. Measurements of internal HOAs revealed a greater negative primary spherical aberration in the EDoF group at pupil sizes of 2.0 to 5.0 mm. At 5.0 mm, total internal HOAs did not differ statistically significantly (0.376 vs 0.340 mm root mean square, P = .068). Conclusions: The Mini Well IOL provided greater depth of focus with superior outcomes at intermediate and near distances and comparable outcomes at far distance. Although inducing higher amounts of spherical aberration, it showed good results under low lighting conditions with little subjective dysphotopsia.
引用
收藏
页码:1139 / 1146
页数:8
相关论文
共 50 条
  • [1] Optical quality in vitro and in vivo of an extended depth-of-focus intraocular lens with isofocal design
    Fernandez-Nunez, Sara
    Perez-Sanz, Lidia
    Gomez-Pedrero, Jose Antonio
    Garcia-Montero, Maria
    Albarran-Diego, Cesar
    Garzon, Nuria
    GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2024, 262 (12) : 3905 - 3913
  • [2] Optical and visual quality assessment of an extended depth-of-focus intraocular lens based on spherical aberration of different sign
    Ruiz-Mesa, Ramon
    Blanch-Ruiz, Julia
    Ruiz-Santos, Maria
    Montes-Mico, Robert
    INTERNATIONAL OPHTHALMOLOGY, 2021, 41 (03) : 1019 - 1032
  • [3] Optical and visual quality assessment of an extended depth-of-focus intraocular lens based on spherical aberration of different sign
    Ramón Ruiz-Mesa
    Julia Blanch-Ruiz
    María Ruiz-Santos
    Robert Montés-Micó
    International Ophthalmology, 2021, 41 : 1019 - 1032
  • [4] Nondiffractive wavefront-shaping extended depth-of-focus intraocular lens: visual performance and patient-reported outcomes
    Kohnen, Thomas
    Petermann, Kerstin
    Boehm, Myriam
    Hemkeppler, Eva
    Ahmad, Wasim
    Hinzelmann, Lisa
    Pawlowicz, Katarzyna
    Jandewerth, Tyll
    Lwowski, Christoph
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2022, 48 (02): : 144 - 150
  • [5] Functional assessment of a new extended depth-of-focus intraocular lens
    Savini, Giacomo
    Balducci, Nicole
    Carbonara, Claudio
    Rossi, Scipione
    Altieri, Manuel
    Frugis, Nicola
    Zappulla, Emilia
    Bellucci, Roberto
    Alessio, Giovanni
    EYE, 2019, 33 (03) : 404 - 410
  • [6] Functional assessment of a new extended depth-of-focus intraocular lens
    Giacomo Savini
    Nicole Balducci
    Claudio Carbonara
    Scipione Rossi
    Manuel Altieri
    Nicola Frugis
    Emilia Zappulla
    Roberto Bellucci
    Giovanni Alessio
    Eye, 2019, 33 : 404 - 410
  • [7] Assessment of the image quality of extended depth-of-focus intraocular lens models in polychromatic light
    Lee, Yumi
    Labuz, Grzegorz
    Son, Hyeck-Soo
    Yildirim, Timur M.
    Khoramnia, Ramin
    Auffarth, Gerd U.
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (01): : 108 - 115
  • [8] Comparison of the Visual Outcomes of an Extended Depth-of-Focus Lens and a Trifocal Lens
    Moshirfar, Majid
    Ellis, James
    Beesley, Daniel
    McCabe, Shannon E.
    Lewis, Adam
    Jnr, William B. West
    Ronquillo, Yasmyne
    Snr, Phillip Hoopes
    CLINICAL OPHTHALMOLOGY, 2021, 15 : 3051 - 3063
  • [9] Visual performance and positional stability of a capsulorhexis-fixated extended depth-of-focus intraocular lens
    Darian-Smith, Erica
    Versace, Patrick
    JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2020, 46 (02): : 179 - 187
  • [10] Clinical outcomes of an extended depth-of-focus intraocular lens in patients with glaucoma
    Dessouky, Reem Amir Kamal
    Aref, Amr
    Mermoud, Andre
    INTERNATIONAL OPHTHALMOLOGY, 2024, 44 (01)